Dosimetric Effect on Breast Cancer Patients Treated with Volumetric-Modulated Arc Therapy: Single Institutional Experience

被引:0
|
作者
Hashem, Rania [1 ]
Mulla, Zaheeda [2 ]
Ghassal, Nour [3 ]
Bokhary, Ayman [1 ]
Howladar, Fatimah [4 ]
Fallatah, Kholoud [4 ]
Iskandarani, Omar [5 ]
Attar, Mohammad [5 ]
Ujaimi, Reem [5 ]
机构
[1] King Abdul Aziz Univ Hosp, Dept Radiol, Jeddah, Saudi Arabia
[2] King Faisal Specialist Hosp & Res Ctr, Dept Oncol, Jeddah, Saudi Arabia
[3] King Faisal Specialist Hosp & Res Ctr, Dept Biomed Phys, Riyadh, Saudi Arabia
[4] King Abdul Aziz Univ Hosp, Dept Med Sch, Jeddah, Saudi Arabia
[5] King Abdulaziz Univ, Dept Radiol, Fac Med, Jeddah, Saudi Arabia
关键词
Breast cancer; Radiotherapy; VMAT; Dosimetry; LOCOREGIONAL RADIATION-THERAPY; HELICAL TOMOTHERAPY; HEART-DISEASE; PLAN QUALITY; RISK; RADIOTHERAPY; IMRT; WOMEN; IRRADIATION; MORTALITY;
D O I
暂无
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Objective: To examine the dosimetric effect of Breast Cancer (BC) patients Receiving Radiotherapy (RT) with Volumetric-Modulated Arc Therapy (VMAT). Methodology: This retrospective study enrolled 53 BC women, treated with VMAT between Oct 2013 and Nov 2018. The fractionation was within 40 Gray-50 Gray (Gy) in 15-25 fractions. Dosimetric parameters, Homogeneity Index (HI), Conformity Index (CI), Mean Heart Dose (MHD), and doses to the Ipsilateral Lung (IPL) and Mean Contralateral Breast (MCB) were analyzed. Results: Dosimetric results for 50 Gy/25 Fx showed, D98% (mean ? standard deviation) was 47.5? 0.8 Gy, PTV D2% was 53 +/- 0.4 Gy, and D50% was 51 +/- 0.3 Gy. The maximum point dose (Dmax), mean +/- SD was 110 +/- (1.4) and the minimum point dose (Dmin), was 72 +/- (9.1). The HI and CI were 0.11 +/- 0.02 and 0.1 +/- 0.07. The average MHD was 10.6 +/- 3.3 Gy, and the MCB dose 4.5 +/- 1.4 Gy, IPL V20Gy 31.5 +/- 4.7%. For hypofractionated dose, D98% (mean dose +/- SD) was 41 +/- 1.6 Gy, PTV D2% was 45 +/- 01.9 Gy and, D50 was 43 +/- 1.8 Gy. The Dmax, mean +/- SD was 111 +/- (5.0) and the Dmin, mean +/- SD was 75 +/- (11). The HI and CI were 0.1 +/- 0.02, and 0.1 +/- 0.34. The average MHD was 10.5 +/- 3.55 Gy, MCB 3.7 +/- 1.4 G, IPL V20 Gy 31.5 +/- 4.7%. Conclusion: VMAT is favorable with complex patient anatomy or when the internal mammary region is included.
引用
收藏
页码:55 / 62
页数:8
相关论文
共 50 条
  • [21] Dosimetric Effect of Rotational Setup Errors in Single-Isocenter Volumetric-Modulated Arc Therapy of Multiple Brain Metastases
    Selvan, Kasirajan Tamil
    Padma, Ganesan
    Revathy, Murugesan Kesavan
    Raj, N. Arunai Nambi
    Senthilnathan, K.
    Babu, P. Ramesh
    JOURNAL OF MEDICAL PHYSICS, 2019, 44 (02) : 84 - 90
  • [22] Optimising image-guidance frequency for patients treated with volumetric-modulated arc therapy for pelvic cancer
    Wongke, Thunyarat
    Nobnop, Wannapha
    Tharavichitkul, Ekkasit
    JOURNAL OF RADIOTHERAPY IN PRACTICE, 2022, 21 (03) : 315 - 320
  • [23] Outcomes of patients with anal cancer treated with volumetric-modulated arc therapy or intensity-modulated radiotherapy and concurrent chemotherapy
    Yucel, Serap
    Kadioglu, Huseyin
    Gural, Zeynep
    Akgun, Zuleyha
    Saglam, Esra Kaytan
    JOURNAL OF CANCER RESEARCH AND THERAPEUTICS, 2021, 17 (01) : 51 - 55
  • [24] Volumetric-modulated arc therapy for adjuvant treatment of endometrial cancer
    Cima, Simona
    Cima, S.
    Valli, M. C.
    Richetti, A.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2019, 195 (12) : 1142 - 1143
  • [25] Analytical dosimetric study of intensity-modulated radiotherapy (IMRT) and volumetric-modulated arc therapy (VMAT) for prostate cancer
    Samir, Fady
    Meaz, Talaat M.
    Hussiny, Fathi AEl
    Ahmed, Ahmed A.
    Mahmoud, Amr A.
    Refaat, Tamer
    Gawish, Ahmed
    Abouegylah, Mohamed
    JOURNAL OF CANCER RESEARCH AND CLINICAL ONCOLOGY, 2023, 149 (09) : 6239 - 6246
  • [26] Analytical dosimetric study of intensity-modulated radiotherapy (IMRT) and volumetric-modulated arc therapy (VMAT) for prostate cancer
    Fady Samir
    Talaat M. Meaz
    Fathi AEl Hussiny
    Ahmed A. Ahmed
    Amr A. Mahmoud
    Tamer Refaat
    Ahmed Gawish
    Mohamed Abouegylah
    Journal of Cancer Research and Clinical Oncology, 2023, 149 : 6239 - 6246
  • [27] Impact of Plan Complexity On the Delivery Accuracy and Dosimetric Accuracy of Volumetric-Modulated Arc Therapy
    Li, G.
    Li, Y.
    Wang, Q.
    Xiao, J.
    Bai, S.
    MEDICAL PHYSICS, 2017, 44 (06) : 2892 - 2892
  • [28] 3D Dosimetric verification of volumetric-modulated arc therapy by portal dosimetry
    Mans, Anton
    Remeijer, Peter
    Olaciregui-Ruiz, Igor
    Wendling, Markus
    Sonke, Jan-Jakob
    Mijnheer, Ben
    van Herk, Marcel
    Stroom, Joep C.
    RADIOTHERAPY AND ONCOLOGY, 2010, 94 (02) : 181 - 187
  • [29] Volumetric Modulated Arc Therapy for patients with bilateral breast cancer
    Lutjeboer, S.
    Rook, J. W. A.
    Stiekema, G.
    Crijns, A. P. G.
    Sijtsema, N. M.
    Blokzijl, E.
    Hietkamp, J.
    Langendijk, J. A.
    van der Borden, A. J.
    Maduro, J. H.
    RADIOTHERAPY AND ONCOLOGY, 2017, 123 : S242 - S243
  • [30] Hybrid volumetric-modulated arc therapy for postoperative breast cancer including regional lymph nodes: the advantage of dosimetric data and safety of toxicities
    Doi, Yoshiko
    Nakao, Minoru
    Miura, Hideharu
    Ozawa, Shuichi
    Kenjo, Masahiro
    Nagata, Yasushi
    JOURNAL OF RADIATION RESEARCH, 2020, 61 (05) : 747 - 754