Effect of prefabricated auxiliary devices and scanning patterns on the accuracy of complete-arch implant digital impressions

被引:2
|
作者
Wu, Hio Kuan [1 ]
Chen, Guanhui [2 ]
Wang, Jing [3 ]
Zhang, Zhengchuan [1 ]
Huang, Xiaoqiong [1 ]
Lin, Xiaoxuan [1 ]
Deng, Feilong [1 ]
Li, Yiming [1 ]
机构
[1] Sun Yat sen Univ, Hosp Stomatol, Guanghua Sch Stomatol, Guangdong Prov Key Lab Stomatol, Guangzhou 510055, Peoples R China
[2] Sun Yat sen Univ, Affiliated Hosp 7, Dept Stomatol, Shenzhen 518107, Guangdong, Peoples R China
[3] YangHe Dent Clin, Guangzhou 510055, Peoples R China
来源
JOURNAL OF DENTISTRY | 2024年 / 140卷
基金
中国国家自然科学基金;
关键词
Accuracy; Dental implant; Digital impression; Intraoral scanner; Scan body; Scanning patterns; STRATEGIES; IMPACT;
D O I
10.1016/j.jdent.2023.104788
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: This study aimed to evaluate the impact of prefabricated auxiliary devices (PAD) and scanning pat-terns on the accuracy of complete-arch implant digital impressions.Methods: An edentulous maxillary model was inserted with four parallel implant analogs and four PAD. The model was scanned with D2000 dental laboratory scanner as the reference scans. Test scans were obtained by 8 different scanning patterns (SP), which including SPA, SPB, SPC, SPD, SPE, SPF, SPG and SPH, with (test group) or without (control group) using the PAD by an intraoral scanner (Aoralscan 3, 3DShining). SPA was the scanning pattern recommended by the manufacturer. Each scanning time was recorded. The related files were imported into inspection software for assessment. Aligned Ranks Transformation ANOVA, Kruskal-Wallis and Mann-Whitney tests were used to evaluate the values. The level of significance was set at alpha = 0.05.Results: The scanning patterns significantly influenced the linear accuracy in the test group and the scanning time for both groups. Lower linear trueness in the test group was found in SPF (p<0.05) and SPG (p<0.05). Longer scanning time was found in SPB and SPG for both groups. The test group demonstrated linear accuracy enhancement in all the scanning patterns; angular trueness enhancement was seen in SPA (p<0.05), SPC (p<0.01) and SPH (p<0.01). Significant longer scanning time was found in SPB (p<0.05), SPF (p<0.05), SPG (p<0.05) and SPH (p<0.05) when using PAD.Conclusion: The scanning patterns impact the accuracy differently depending on the PAD's existence. The scanning time can be significantly influenced by the scanning patterns and the PAD.
引用
收藏
页数:11
相关论文
共 50 条
  • [31] Influence of the surface humidity, implant angulation, and interimplant distance on the accuracy and scanning time of complete-arch implant scans
    Gomez-Polo, Miguel
    Ortega, Rocio
    Sallorenzo, Alessandro
    Agustin-Panadero, Ruben
    Barmak, Abdul B.
    Kois, John C.
    Revilla-Leon, Marta
    [J]. JOURNAL OF DENTISTRY, 2022, 127
  • [32] Influence of Implant Scanbody Wear on the Accuracy of Digital Impression for Complete-Arch: A Randomized In Vitro Trial
    Arcuri, Lorenzo
    Lio, Fabrizio
    Campana, Veronica
    Mazzetti, Vincenzo
    Federici, Francesca Romana
    Nardi, Alessandra
    Galli, Massimo
    [J]. MATERIALS, 2022, 15 (03)
  • [33] TRUENESS EVALUATION OF LATEST GENERATION OF INTRAORAL SCANNERS ON COMPLETE-ARCH IMPLANT IMPRESSIONS
    Issever, Dilara Seyma Alpkilic
    Deger, Sabire isler
    [J]. INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2023, 36 (04) : e1 - e12
  • [34] Three-Dimensional Accuracy of Conventional Versus Digital Complete Arch Implant Impressions
    Albayrak, Berkman
    Sukotjo, Cortino
    Wee, Alvin G.
    Korkmaz, Ismail Hakki
    Bayindir, Funda
    [J]. JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2021, 30 (02): : 163 - 170
  • [35] ACCURACY OF COMPLETE-ARCH DENTAL IMPRESSIONS: A NEW METHOD OF MEASURING TRUENESS AND PRECISION
    Ender, Andreas
    Mehl, Albert
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2013, 109 (02): : 121 - 128
  • [36] Accuracy analysis of complete-arch digital scans in edentulous arches when using an auxiliary geometric device
    Iturrate, Mikel
    Eguiraun, Harkaitz
    Etxaniz, Olatz
    Solaberrieta, Eneko
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2019, 121 (03): : 447 - 454
  • [37] Accuracy of complete-arch implant impression made with occlusal registration material
    Papazoglou, Efstratios
    Wee, Alvin G.
    Carr, Alan B.
    Urban, Istvan
    Margaritis, Vasileios
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2020, 123 (01): : 143 - 148
  • [38] Effect of Scanner Type and Scan Body Location on the Accuracy of Mandibular Complete-Arch Digital Implant Scans: An In Vitro Study
    Cakmak, Gulce
    Yilmaz, Hakan
    Santos, Alejandro Trevino
    Kokat, Ali Murat
    Yilmaz, Burak
    [J]. JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2022, 31 (05): : 419 - 426
  • [39] In vivo precision of conventional and digital methods of obtaining complete-arch dental impressions
    Ender, Andreas
    Attin, Thomas
    Mehl, Albert
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2016, 115 (03): : 313 - 320
  • [40] Effect of Arch Size and Implant Angulations on the Accuracy of Implant Impressions
    Rezaei, Susan Mirmohammad
    Geramipanah, Farideh
    Kamali, Hadi
    Sadighpour, Leyla
    Payaminia, Leila
    [J]. EUROPEAN JOURNAL OF PROSTHODONTICS AND RESTORATIVE DENTISTRY, 2021, 29 (04): : 218 - 222