Effect of prefabricated auxiliary devices and scanning patterns on the accuracy of complete-arch implant digital impressions

被引:2
|
作者
Wu, Hio Kuan [1 ]
Chen, Guanhui [2 ]
Wang, Jing [3 ]
Zhang, Zhengchuan [1 ]
Huang, Xiaoqiong [1 ]
Lin, Xiaoxuan [1 ]
Deng, Feilong [1 ]
Li, Yiming [1 ]
机构
[1] Sun Yat sen Univ, Hosp Stomatol, Guanghua Sch Stomatol, Guangdong Prov Key Lab Stomatol, Guangzhou 510055, Peoples R China
[2] Sun Yat sen Univ, Affiliated Hosp 7, Dept Stomatol, Shenzhen 518107, Guangdong, Peoples R China
[3] YangHe Dent Clin, Guangzhou 510055, Peoples R China
来源
JOURNAL OF DENTISTRY | 2024年 / 140卷
基金
中国国家自然科学基金;
关键词
Accuracy; Dental implant; Digital impression; Intraoral scanner; Scan body; Scanning patterns; STRATEGIES; IMPACT;
D O I
10.1016/j.jdent.2023.104788
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: This study aimed to evaluate the impact of prefabricated auxiliary devices (PAD) and scanning pat-terns on the accuracy of complete-arch implant digital impressions.Methods: An edentulous maxillary model was inserted with four parallel implant analogs and four PAD. The model was scanned with D2000 dental laboratory scanner as the reference scans. Test scans were obtained by 8 different scanning patterns (SP), which including SPA, SPB, SPC, SPD, SPE, SPF, SPG and SPH, with (test group) or without (control group) using the PAD by an intraoral scanner (Aoralscan 3, 3DShining). SPA was the scanning pattern recommended by the manufacturer. Each scanning time was recorded. The related files were imported into inspection software for assessment. Aligned Ranks Transformation ANOVA, Kruskal-Wallis and Mann-Whitney tests were used to evaluate the values. The level of significance was set at alpha = 0.05.Results: The scanning patterns significantly influenced the linear accuracy in the test group and the scanning time for both groups. Lower linear trueness in the test group was found in SPF (p<0.05) and SPG (p<0.05). Longer scanning time was found in SPB and SPG for both groups. The test group demonstrated linear accuracy enhancement in all the scanning patterns; angular trueness enhancement was seen in SPA (p<0.05), SPC (p<0.01) and SPH (p<0.01). Significant longer scanning time was found in SPB (p<0.05), SPF (p<0.05), SPG (p<0.05) and SPH (p<0.05) when using PAD.Conclusion: The scanning patterns impact the accuracy differently depending on the PAD's existence. The scanning time can be significantly influenced by the scanning patterns and the PAD.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Accuracy of intraoral scan with prefabricated aids and stereophotogrammetry compared with open tray impressions for complete-arch implant-supported prosthesis: A clinical study
    Fu, Xiao-Jiao
    Liu, Min
    Liu, Bei-Lei
    Tonetti, Maurizio S.
    Shi, Jun-Yu
    Lai, Hong-Chang
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2024, 35 (08) : 830 - 840
  • [22] In Vivo Complete-Arch Implant Digital Impressions: Comparison of the Precision of Three Optical Impression Systems
    Orejas-Perez, Jaime
    Gimenez-Gonzalez, Beatriz
    Ortiz-Collado, Ignacio
    Thuissard, Israel J.
    Santamaria-Laorden, Andrea
    [J]. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2022, 19 (07)
  • [23] Comparison of Different Intraoral Scanners With Prefabricated Aid on Accuracy and Framework Passive Fit of Digital Complete-Arch Implant Impression: An In Vitro Study
    Fu, Xiao-Jiao
    Liu, Min
    Shi, Jun-Yu
    Deng, Ke
    Lai, Hong-Chang
    Gu, Wen
    Zhang, Xiao-Meng
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2024,
  • [24] Accuracy of four digital scanners according to scanning strategy in complete-arch impressions (vol 13, e0202916, 2018)
    Medina-Sotomayor, Priscilla
    Pascual-Moscardo, Agustin
    Camps, Isabel
    [J]. PLOS ONE, 2018, 13 (12):
  • [25] Accuracy of complete-arch digital implant impression with or without scanbody splinting: An in vitro study
    Pozzi, Alessandro
    Arcuri, Lorenzo
    Lio, Fabrizio
    Papa, Andrea
    Nardi, Alessandra
    Londono, Jimmy
    [J]. JOURNAL OF DENTISTRY, 2022, 119
  • [26] Evaluating the impact of scan body angulation and geometric attachments on the accuracy of complete-arch digital implant impressions: A comparison of two intraoral scanners
    Farah, Ra'fat I.
    Alresheedi, Bandar
    Alazmi, Saad
    Al-Haj Ali, Sanaa N.
    [J]. JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2023,
  • [27] A clinical pilot study of the dimensional accuracy of double-arch and complete-arch impressions
    Cox, JR
    Brandt, RL
    Hughes, HJ
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2002, 87 (05): : 510 - 515
  • [28] Guided implant scanning: A procedure for improving the accuracy of implant-supported complete-arch fixed dental prostheses
    Gomez-Polo, Miguel
    Ballesteros, Juan
    Perales-Padilla, Pedro
    Perales-Pulido, Pedro
    Gomez-Polo, Cristina
    Ortega, Rocio
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2020, 124 (02): : 135 - 139
  • [29] Accuracy of three digital scanning methods for complete-arch tooth preparation: An in vitro comparison
    Gao, Hanqi
    Liu, Xiaoqiang
    Liu, Mingyue
    Yang, Xu
    Tan, Jianguo
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2022, 128 (05): : 1001 - 1008
  • [30] Impact of different scanning strategies on the accuracy of two current intraoral scanning systems in complete-arch impressions: an in vitro study
    Passos, Leandro
    Meiga, Sergio
    Brigagao, Vinicius
    Street, Alexandre
    [J]. INTERNATIONAL JOURNAL OF COMPUTERIZED DENTISTRY, 2019, 22 (04) : 307 - 319