Effect of prefabricated auxiliary devices and scanning patterns on the accuracy of complete-arch implant digital impressions

被引:2
|
作者
Wu, Hio Kuan [1 ]
Chen, Guanhui [2 ]
Wang, Jing [3 ]
Zhang, Zhengchuan [1 ]
Huang, Xiaoqiong [1 ]
Lin, Xiaoxuan [1 ]
Deng, Feilong [1 ]
Li, Yiming [1 ]
机构
[1] Sun Yat sen Univ, Hosp Stomatol, Guanghua Sch Stomatol, Guangdong Prov Key Lab Stomatol, Guangzhou 510055, Peoples R China
[2] Sun Yat sen Univ, Affiliated Hosp 7, Dept Stomatol, Shenzhen 518107, Guangdong, Peoples R China
[3] YangHe Dent Clin, Guangzhou 510055, Peoples R China
来源
JOURNAL OF DENTISTRY | 2024年 / 140卷
基金
中国国家自然科学基金;
关键词
Accuracy; Dental implant; Digital impression; Intraoral scanner; Scan body; Scanning patterns; STRATEGIES; IMPACT;
D O I
10.1016/j.jdent.2023.104788
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: This study aimed to evaluate the impact of prefabricated auxiliary devices (PAD) and scanning pat-terns on the accuracy of complete-arch implant digital impressions.Methods: An edentulous maxillary model was inserted with four parallel implant analogs and four PAD. The model was scanned with D2000 dental laboratory scanner as the reference scans. Test scans were obtained by 8 different scanning patterns (SP), which including SPA, SPB, SPC, SPD, SPE, SPF, SPG and SPH, with (test group) or without (control group) using the PAD by an intraoral scanner (Aoralscan 3, 3DShining). SPA was the scanning pattern recommended by the manufacturer. Each scanning time was recorded. The related files were imported into inspection software for assessment. Aligned Ranks Transformation ANOVA, Kruskal-Wallis and Mann-Whitney tests were used to evaluate the values. The level of significance was set at alpha = 0.05.Results: The scanning patterns significantly influenced the linear accuracy in the test group and the scanning time for both groups. Lower linear trueness in the test group was found in SPF (p<0.05) and SPG (p<0.05). Longer scanning time was found in SPB and SPG for both groups. The test group demonstrated linear accuracy enhancement in all the scanning patterns; angular trueness enhancement was seen in SPA (p<0.05), SPC (p<0.01) and SPH (p<0.01). Significant longer scanning time was found in SPB (p<0.05), SPF (p<0.05), SPG (p<0.05) and SPH (p<0.05) when using PAD.Conclusion: The scanning patterns impact the accuracy differently depending on the PAD's existence. The scanning time can be significantly influenced by the scanning patterns and the PAD.
引用
收藏
页数:11
相关论文
共 50 条
  • [41] Maxillary complete-arch implant-supported restoration: A digital scanning and maxillomandibular relationship work flow
    Ahmed, Walaa Magdy
    Verhaeghe, Tyler V.
    McCullagh, Anthony P. G.
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2021, 125 (02): : 216 - 220
  • [42] Accuracy of intraoral optical scan versus stereophotogrammetry for complete-arch digital implant impression: An in vitro study
    Pozzi, Alessandro
    Agliardi, Enrico
    Lio, Fabrizio
    Nagy, Katalin
    Nardi, Alessandra
    Arcuri, Lorenzo
    [J]. JOURNAL OF PROSTHODONTIC RESEARCH, 2024, 68 (01) : 172 - 180
  • [43] Impact of color temperature and illuminance of ambient light conditions on the accuracy of complete-arch digital implant scans
    Ochoa-Lopez, Gaston
    Revilla-Leon, Marta
    Gomez-Polo, Miguel
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2024, 35 (08) : 898 - 905
  • [44] Influence of ambient light conditions on the accuracy and scanning time of seven intraoral scanners in complete-arch implant scans
    Ochoa-Lopez, Gaston
    Cascos, Rocio
    Antonaya-Martin, Jose Luis
    Revilla-Leon, Marta
    Gomez-Polo, Miguel
    [J]. JOURNAL OF DENTISTRY, 2022, 121
  • [45] Effect of simulated intraoral variables on the accuracy of a photogrammetric imaging technique for complete-arch implant prostheses
    Bratos, Manuel
    Bergin, Jumping M.
    Rubenstein, Jeffrey E.
    Sorensen, John A.
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2018, 120 (02): : 232 - 241
  • [46] Accuracy of photogrammetry, intraoral scanning, and conventional impression techniques for complete-arch implant rehabilitation: an in vitro comparative study
    Bowen Ma
    Xinxin Yue
    Yujie Sun
    Lingyan Peng
    Wei Geng
    [J]. BMC Oral Health, 21
  • [47] Classification of Complete-Arch Implant Scanning Techniques Recorded by Using Intraoral Scanners
    Revilla-Leon, Marta
    Gomez-Polo, Miguel
    Rutkunas, Vygandas
    Ntovas, Panagiotis
    Kois, John C.
    [J]. JOURNAL OF ESTHETIC AND RESTORATIVE DENTISTRY, 2024,
  • [48] Effect of using scan body accessories and inter-implant distances on the accuracy of complete arch implant digital impressions: An in vitro study
    Ashry, Amal
    Abdelhamid, Ahmed M.
    Ezzelarab, Salah
    Khamis, Mohamed Moataz
    [J]. JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2024,
  • [49] Accuracy of photogrammetry, intraoral scanning, and conventional impression techniques for complete-arch implant rehabilitation: an in vitro comparative study
    Ma, Bowen
    Yue, Xinxin
    Sun, Yujie
    Peng, Lingyan
    Geng, Wei
    [J]. BMC ORAL HEALTH, 2021, 21 (01)
  • [50] Complete digital workflow in prosthesis prototype fabrication for complete-arch implant rehabilitation: A technique
    Papaspyridakos, Panos
    Chen, Yo-wei
    Gonzalez-Gusmao, Ilenia
    Att, Wael