Accuracy of photogrammetry, intraoral scanning, and conventional impression techniques for complete-arch implant rehabilitation: an in vitro comparative study

被引:0
|
作者
Bowen Ma
Xinxin Yue
Yujie Sun
Lingyan Peng
Wei Geng
机构
[1] Capital Medical University,Department of Dental Implant Center, Beijing Stomatological Hospital, School of Stomatology
[2] Beijing Citident Stomatology Hospital,Department of Prosthodontics
来源
关键词
Dental impression technique; Dental implants; Edentulous; Photogrammetry; Intraoral scanning; Conventional impression; Accuracy;
D O I
暂无
中图分类号
学科分类号
摘要
引用
收藏
相关论文
共 50 条
  • [1] Accuracy of photogrammetry, intraoral scanning, and conventional impression techniques for complete-arch implant rehabilitation: an in vitro comparative study
    Ma, Bowen
    Yue, Xinxin
    Sun, Yujie
    Peng, Lingyan
    Geng, Wei
    [J]. BMC ORAL HEALTH, 2021, 21 (01)
  • [2] Comparison of conventional, photogrammetry, and intraoral scanning accuracy of complete-arch implant impression procedures evaluated with a coordinate measuring machine
    Revilla-Leon, Marta
    Att, Wael
    Ozcan, Mutlu
    Rubenstein, Jeffrey
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2021, 125 (03): : 470 - 478
  • [3] Accuracy of Implant Level Intraoral Scanning and Photogrammetry Impression Techniques in a Complete Arch with Angled and Parallel Implants: An In Vitro Study
    Tohme, Hani
    Lawand, Ghida
    Eid, Rita
    Ahmed, Khaled E.
    Salameh, Ziad
    Makzoume, Joseph
    [J]. APPLIED SCIENCES-BASEL, 2021, 11 (21):
  • [4] Accuracy of complete-arch digital implant impression with intraoral optical scanning and stereophotogrammetry: An in vivo prospective comparative study
    Pozzi, Alessandro
    Carosi, Paolo
    Gallucci, German O.
    Nagy, Katalin
    Nardi, Alessandra
    Arcuri, Lorenzo
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2023, 34 (10) : 1106 - 1117
  • [5] AN IN VITRO COMPARISON OF PHOTOGRAMMETRIC AND CONVENTIONAL COMPLETE-ARCH IMPLANT IMPRESSION TECHNIQUES
    Bergin, Junping Ma
    Rubenstein, Jeffrey E.
    Mancl, Lloyd
    Brudvik, James S.
    Raigrodski, Ariel J.
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2013, 110 (04): : 243 - 251
  • [6] Improved scanning accuracy with newly designed scan bodies: An in vitro study comparing digital versus conventional impression techniques for complete-arch implant rehabilitation
    Huang, Ruoxuan
    Liu, Yuanxiang
    Huang, Baoxin
    Zhang, Chaobiao
    Chen, Zhuofan
    Li, Zhipeng
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2020, 31 (07) : 625 - 633
  • [7] Accuracy of intraoral optical scan versus stereophotogrammetry for complete-arch digital implant impression: An in vitro study
    Pozzi, Alessandro
    Agliardi, Enrico
    Lio, Fabrizio
    Nagy, Katalin
    Nardi, Alessandra
    Arcuri, Lorenzo
    [J]. JOURNAL OF PROSTHODONTIC RESEARCH, 2024, 68 (01) : 172 - 180
  • [8] Comparative Analysis of Intraoral Scanner Accuracy in a Six-Implant Complete-Arch Model: An In Vitro Study
    Ferrini, Francesco
    Mazzoleni, Federica
    Barbini, Matteo
    Coppo, Carlotta
    Di Domenico, Giovanna Laura
    Gherlone, Enrico Felice
    [J]. PROSTHESIS, 2024, 6 (02): : 401 - 412
  • [9] Classification of Complete-Arch Implant Scanning Techniques Recorded by Using Intraoral Scanners
    Revilla-Leon, Marta
    Gomez-Polo, Miguel
    Rutkunas, Vygandas
    Ntovas, Panagiotis
    Kois, John C.
    [J]. JOURNAL OF ESTHETIC AND RESTORATIVE DENTISTRY, 2024,
  • [10] Accuracy of complete-arch digital implant impression with or without scanbody splinting: An in vitro study
    Pozzi, Alessandro
    Arcuri, Lorenzo
    Lio, Fabrizio
    Papa, Andrea
    Nardi, Alessandra
    Londono, Jimmy
    [J]. JOURNAL OF DENTISTRY, 2022, 119