TRUENESS EVALUATION OF LATEST GENERATION OF INTRAORAL SCANNERS ON COMPLETE-ARCH IMPLANT IMPRESSIONS

被引:2
|
作者
Issever, Dilara Seyma Alpkilic [1 ,2 ]
Deger, Sabire isler [1 ]
机构
[1] Istanbul Univ, Fac Dent, Dept Prosthodont, Istanbul, Turkiye
[2] Prof Dr Cavit Orhan Tutengil Sk 4, TR-34116 Istanbul, Turkiye
关键词
AMBIENT LIGHT; ACCURACY; PRECISION;
D O I
10.11607/ijp.7824
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: To evaluate the trueness of five intraoral scanners on a fully edentulous model with seven implants. Materials and Methods: The study model was created from gypsum with seven implant analogs that were placed with 2-mm gingival height and a 0-degree angle at tooth sites 47, 45, 43, 31, 33, 35, and 37 (FDI system). The study model was scanned 10 times (n = 10) with five intraoral scanners (CS 3600, Emerald S, Primescan, Trios 3, and Trios 4). The study model was digitized with a high-resolution industrial desktop scanner, and the data were imported into reverse-engineering software to be used as the reference model. The trueness assessment was performed digitally with superimposition using the software. Linear measurements were calculated as the differences between the centers of the scan bodies on the study models vs the reference model. Volumetric deviations were calculated with root mean square values. Data obtained in the study were analyzed statistically using one-way analysis of variance and Tukey tests. A value of P < .05 was accepted as statistically significant. Results: In linear measurements, Trios 4 showed the best trueness results, followed by Trios 3, Emerald S, Primescan, and CS 3600. Trios 4 showed statistically higher trueness results than CS 3600 (P = .029). However, no statistically significant differences were found between groups in volumetric measurements (P < .05). Conclusions: All of the intraoral scanners used in the study showed favorable deviation values for an edentulous model with seven implants. Trios 4 showed the best trueness values. The latest generation of intraoral scanners can be used in full-arch implant impressions.
引用
收藏
页码:e1 / e12
页数:12
相关论文
共 50 条
  • [1] In Vitro Trueness and Precision of Intraoral Scanners in a Four-Implant Complete-Arch Model
    Spagopoulos, Dimitrios
    Kaisarlis, George
    Spagopoulou, Foteini
    Halazonetis, Demetrios J. J.
    Gueth, Jan-Frederik
    Papazoglou, Efstratios
    DENTISTRY JOURNAL, 2023, 11 (01)
  • [2] RESEARCH AND EDUCATION Evaluation of complete-arch implant scanning with 5 different intraoral scanners in terms of trueness and operator experience
    Revell, Griffin
    Simon, Botond
    Mennito, Anthony
    Evans, Zachary P.
    Renne, Walter
    Ludlow, Mark
    Vag, Janos
    JOURNAL OF PROSTHETIC DENTISTRY, 2022, 128 (04): : 632 - 638
  • [3] Effect of Scan Pattern on the Accuracy of Complete-Arch Digital Implant Impressions with Two Intraoral Scanners
    Li, Zhipeng
    Huang, Ruoxuan
    Wu, Xiayi
    Chen, Zetao
    Huang, Baoxin
    Chen, Zhuofan
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2022, 37 (04) : 731 - 739
  • [4] In vitro comparison of trueness of 10 intraoral scanners for implant-supported complete-arch fixed dental prostheses
    Bilmenoglu, Caglar
    Cilingir, Altug
    Geckili, Onur
    Bilhan, Hakan
    Bilgin, Tayfun
    JOURNAL OF PROSTHETIC DENTISTRY, 2020, 124 (06): : 755 - 760
  • [5] Complete-arch accuracy of intraoral scanners
    Treesh, Joshua C.
    Liacouras, Peter C.
    Taft, Robert M.
    Brooks, Daniel, I
    Raiciulescu, Sorana
    Ellert, Daniel O.
    Grant, Gerald T.
    Ye, Ling
    JOURNAL OF PROSTHETIC DENTISTRY, 2018, 120 (03): : 382 - 388
  • [6] Effect of splinting scan bodies on trueness of complete-arch implant impression using different intraoral scanners: an in vitro study
    Retana, Luciano
    Nejat, Amir H.
    Pozzi, Alessandro
    INTERNATIONAL JOURNAL OF COMPUTERIZED DENTISTRY, 2023, 26 (01) : 19 - 28
  • [7] Classification of Complete-Arch Implant Scanning Techniques Recorded by Using Intraoral Scanners
    Revilla-Leon, Marta
    Gomez-Polo, Miguel
    Rutkunas, Vygandas
    Ntovas, Panagiotis
    Kois, John C.
    JOURNAL OF ESTHETIC AND RESTORATIVE DENTISTRY, 2024,
  • [8] Trueness and precision of digital implant impressions by intraoral scanners: a literature review
    Sanda, Minoru
    Miyoshi, Keita
    Baba, Kazuyoshi
    INTERNATIONAL JOURNAL OF IMPLANT DENTISTRY, 2021, 7 (01)
  • [9] Trueness and precision of digital implant impressions by intraoral scanners: a literature review
    Minoru Sanda
    Keita Miyoshi
    Kazuyoshi Baba
    International Journal of Implant Dentistry, 7
  • [10] Complete-Arch Accuracy of Four Intraoral Scanners: An In Vitro Study
    Celeghin, Giordano
    Franceschetti, Giulio
    Mobilio, Nicola
    Fasiol, Alberto
    Catapano, Santo
    Corsalini, Massimo
    Grande, Francesco
    HEALTHCARE, 2021, 9 (03)