TRUENESS EVALUATION OF LATEST GENERATION OF INTRAORAL SCANNERS ON COMPLETE-ARCH IMPLANT IMPRESSIONS

被引:2
|
作者
Issever, Dilara Seyma Alpkilic [1 ,2 ]
Deger, Sabire isler [1 ]
机构
[1] Istanbul Univ, Fac Dent, Dept Prosthodont, Istanbul, Turkiye
[2] Prof Dr Cavit Orhan Tutengil Sk 4, TR-34116 Istanbul, Turkiye
关键词
AMBIENT LIGHT; ACCURACY; PRECISION;
D O I
10.11607/ijp.7824
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: To evaluate the trueness of five intraoral scanners on a fully edentulous model with seven implants. Materials and Methods: The study model was created from gypsum with seven implant analogs that were placed with 2-mm gingival height and a 0-degree angle at tooth sites 47, 45, 43, 31, 33, 35, and 37 (FDI system). The study model was scanned 10 times (n = 10) with five intraoral scanners (CS 3600, Emerald S, Primescan, Trios 3, and Trios 4). The study model was digitized with a high-resolution industrial desktop scanner, and the data were imported into reverse-engineering software to be used as the reference model. The trueness assessment was performed digitally with superimposition using the software. Linear measurements were calculated as the differences between the centers of the scan bodies on the study models vs the reference model. Volumetric deviations were calculated with root mean square values. Data obtained in the study were analyzed statistically using one-way analysis of variance and Tukey tests. A value of P < .05 was accepted as statistically significant. Results: In linear measurements, Trios 4 showed the best trueness results, followed by Trios 3, Emerald S, Primescan, and CS 3600. Trios 4 showed statistically higher trueness results than CS 3600 (P = .029). However, no statistically significant differences were found between groups in volumetric measurements (P < .05). Conclusions: All of the intraoral scanners used in the study showed favorable deviation values for an edentulous model with seven implants. Trios 4 showed the best trueness values. The latest generation of intraoral scanners can be used in full-arch implant impressions.
引用
收藏
页码:e1 / e12
页数:12
相关论文
共 50 条
  • [21] Accuracy of four digital scanners according to scanning strategy in complete-arch impressions
    Medina-Sotomayor, Priscilla
    Pascual M., Agustin
    Camps A., Isabel
    PLOS ONE, 2018, 13 (09):
  • [22] Evaluation of the trueness and precision of eight extraoral laboratory scanners with a complete-arch model: a three-dimensional analysis
    Emir, Faruk
    Ayyildiz, Simel
    JOURNAL OF PROSTHODONTIC RESEARCH, 2019, 63 (04) : 434 - 439
  • [23] Evaluation of the accuracy of intraoral scanners for complete-arch scanning: A systematic review and network meta-analysis
    Vitai, Viktoria
    Nemeth, Anna
    Solyom, Eleonora
    Czumbel, Laszlo Mark
    Szabo, Bence
    Fazekas, Reka
    Gerber, Gabor
    Hegyi, Peter
    Hermann, Peter
    Borbely, Judit
    JOURNAL OF DENTISTRY, 2023, 137
  • [24] Trueness of 12 intraoral scanners in the full-arch implant impression: a comparative in vitro study
    Francesco Guido Mangano
    Oleg Admakin
    Matteo Bonacina
    Henriette Lerner
    Vygandas Rutkunas
    Carlo Mangano
    BMC Oral Health, 20
  • [25] Trueness of 12 intraoral scanners in the full-arch implant impression: a comparative in vitro study
    Mangano, Francesco Guido
    Admakin, Oleg
    Bonacina, Matteo
    Lerner, Henriette
    Rutkunas, Vygandas
    Mangano, Carlo
    BMC ORAL HEALTH, 2020, 20 (01)
  • [26] Complete-arch accuracy of seven intraoral scanners measured by the virtual-fit method
    Borbola, Daniel
    Mikolicz, Akos
    Romanszky, Laszlo
    Sersli, Gyorgy
    DeFee, Michael
    Renne, Walter
    Vag, Janos
    JOURNAL OF DENTISTRY, 2024, 149
  • [27] Effect of scan powder and scanning technology on measured deviations of complete-arch implant supported frameworks digitized with industrial and intraoral scanners
    Donmez, Mustafa Borga
    Cakmak, Gulce
    Dede, Dogu Omur
    Kucukekenci, Ahmet Serkan
    Lu, Wei-En
    Schumacher, Fernanda Lang
    Revilla-Leon, Marta
    Yilmaz, Burak
    JOURNAL OF DENTISTRY, 2023, 138
  • [28] Accuracy of a new elastomeric impression material for complete-arch dental implant impressions
    Baig, Mirza R.
    Buzayan, Muaiyed M.
    Yunus, Norsiah
    JOURNAL OF INVESTIGATIVE AND CLINICAL DENTISTRY, 2018, 9 (02) : e12320
  • [29] Trueness and precision of complete-arch photogrammetry implant scanning assessed with a coordinate-measuring machine
    Revilla-Leon, Marta
    Rubenstein, Jeffrey
    Methani, Mohammed M.
    Piedra-Cascon, Wenceslao
    Ozcan, Mutlu
    Att, Wael
    JOURNAL OF PROSTHETIC DENTISTRY, 2023, 129 (01): : 160 - 165
  • [30] Evaluation of the accuracy of seven intraoral scanners for the full dentate and partially edentulous complete-arch mandibular casts: An in vitro comparison
    Wang, Xin
    Zhang, Fang
    Ma, Dan
    Ye, Xiaolan
    Zheng, Xiaojuan
    Ren, Ruifang
    Ren, Nan
    Bai, Shizhu
    HELIYON, 2024, 10 (10)