TRUENESS EVALUATION OF LATEST GENERATION OF INTRAORAL SCANNERS ON COMPLETE-ARCH IMPLANT IMPRESSIONS

被引:2
|
作者
Issever, Dilara Seyma Alpkilic [1 ,2 ]
Deger, Sabire isler [1 ]
机构
[1] Istanbul Univ, Fac Dent, Dept Prosthodont, Istanbul, Turkiye
[2] Prof Dr Cavit Orhan Tutengil Sk 4, TR-34116 Istanbul, Turkiye
关键词
AMBIENT LIGHT; ACCURACY; PRECISION;
D O I
10.11607/ijp.7824
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: To evaluate the trueness of five intraoral scanners on a fully edentulous model with seven implants. Materials and Methods: The study model was created from gypsum with seven implant analogs that were placed with 2-mm gingival height and a 0-degree angle at tooth sites 47, 45, 43, 31, 33, 35, and 37 (FDI system). The study model was scanned 10 times (n = 10) with five intraoral scanners (CS 3600, Emerald S, Primescan, Trios 3, and Trios 4). The study model was digitized with a high-resolution industrial desktop scanner, and the data were imported into reverse-engineering software to be used as the reference model. The trueness assessment was performed digitally with superimposition using the software. Linear measurements were calculated as the differences between the centers of the scan bodies on the study models vs the reference model. Volumetric deviations were calculated with root mean square values. Data obtained in the study were analyzed statistically using one-way analysis of variance and Tukey tests. A value of P < .05 was accepted as statistically significant. Results: In linear measurements, Trios 4 showed the best trueness results, followed by Trios 3, Emerald S, Primescan, and CS 3600. Trios 4 showed statistically higher trueness results than CS 3600 (P = .029). However, no statistically significant differences were found between groups in volumetric measurements (P < .05). Conclusions: All of the intraoral scanners used in the study showed favorable deviation values for an edentulous model with seven implants. Trios 4 showed the best trueness values. The latest generation of intraoral scanners can be used in full-arch implant impressions.
引用
收藏
页码:e1 / e12
页数:12
相关论文
共 50 条
  • [31] Comparison of Different Intraoral Scanners With Prefabricated Aid on Accuracy and Framework Passive Fit of Digital Complete-Arch Implant Impression: An In Vitro Study
    Fu, Xiao-Jiao
    Liu, Min
    Shi, Jun-Yu
    Deng, Ke
    Lai, Hong-Chang
    Gu, Wen
    Zhang, Xiao-Meng
    CLINICAL ORAL IMPLANTS RESEARCH, 2024,
  • [32] Trueness and precision of intraoral scanners in the maxillary dental arch: an in vivo analysis
    Jonas Winkler
    Nikolaos Gkantidis
    Scientific Reports, 10
  • [33] Trueness and precision of intraoral scanners in the maxillary dental arch: an in vivo analysis
    Winkler, Jonas
    Gkantidis, Nikolaos
    SCIENTIFIC REPORTS, 2020, 10 (01)
  • [34] Dimensional accuracy of different techniques used for complete-arch multi-implant impressions
    Ghanem, Rabab A.
    Nassani, Mohammad Z.
    Baroudi, Kusai
    Fattah, Amany Abdel
    JOURNAL OF INVESTIGATIVE AND CLINICAL DENTISTRY, 2016, 7 (03) : 225 - 231
  • [35] Trueness and precision of mandibular complete-arch implant scans when different data acquisition methods are used
    Demirel, Munir
    Donmez, Mustafa Borga
    Sahmali, Sevil Meral
    JOURNAL OF DENTISTRY, 2023, 138
  • [36] Effects of the intraoral scanner and implant library on the trueness of digital impressions in the full-arch implant scan: A comparative in vitro study
    Hauschild, Uli
    Lerner, Henriette
    Weigl, Paul
    Porra, Tommaso
    Admakin, Oleg
    Mangano, Francesco Guido
    JOURNAL OF DENTISTRY, 2024, 150
  • [37] Accuracy of intraoral scan with prefabricated aids and stereophotogrammetry compared with open tray impressions for complete-arch implant-supported prosthesis: A clinical study
    Fu, Xiao-Jiao
    Liu, Min
    Liu, Bei-Lei
    Tonetti, Maurizio S.
    Shi, Jun-Yu
    Lai, Hong-Chang
    CLINICAL ORAL IMPLANTS RESEARCH, 2024, 35 (08) : 830 - 840
  • [38] Comparison of different artificial landmarks and scanning patterns on the complete-arch implant intraoral digital scans
    Kanjanasavitree, Primprapa
    Thammajaruk, Putsadeeporn
    Guazzato, Massimiliano
    JOURNAL OF DENTISTRY, 2022, 125
  • [39] Effect of simulated intraoral variables on the accuracy of a photogrammetric imaging technique for complete-arch implant prostheses
    Bratos, Manuel
    Bergin, Jumping M.
    Rubenstein, Jeffrey E.
    Sorensen, John A.
    JOURNAL OF PROSTHETIC DENTISTRY, 2018, 120 (02): : 232 - 241
  • [40] Orthodontic elastomeric chain as an alternative to dental floss for splinting implant impression copings for complete-arch implant impressions
    Joshi, Amruta A.
    Gaikwad, Amit M.
    Nadgere, Jyoti B.
    Ram, Sabita M.
    JOURNAL OF PROSTHETIC DENTISTRY, 2020, 123 (01): : 188 - 189