Accuracy of complete-arch implant impression made with occlusal registration material

被引:9
|
作者
Papazoglou, Efstratios [1 ]
Wee, Alvin G. [2 ]
Carr, Alan B. [3 ]
Urban, Istvan [4 ,5 ]
Margaritis, Vasileios [6 ]
机构
[1] Univ Athens, Dept Operat Dent, 2 Thivon St, Athens 11527, Greece
[2] Univ Minnesota, Sch Dent, Div Prosthodont, Minneapolis, MN 55455 USA
[3] Mayo Clin, Dept Dent Special, Rochester, MN USA
[4] Loma Linda Univ, Dept Restorat Dent, Loma Linda, CA 92350 USA
[5] Univ Michigan, Dept Periodontol & Oral Med, Ann Arbor, MI 48109 USA
[6] Walden Univ, Dept Publ Hlth, Minneapolis, MN USA
来源
JOURNAL OF PROSTHETIC DENTISTRY | 2020年 / 123卷 / 01期
关键词
BONE; PROSTHESES; FIT; ADAPTATION; STOCK;
D O I
10.1016/j.prosdent.2018.12.011
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. Which impression material, impression tray type, and implant impression technique combination produces the most accurate complete-arch impression is unclear. Purpose. The purpose of this in vitro study was to compare the implant impression accuracy of a completely edentulous arch made with addition silicone occlusal registration material and an open tray with the implant impression accuracy of other conventional impression techniques. Material and methods. Amaster cast was fabricated from Type IVgypsum with four 3.8-mm diameter implants with internal hexagon located in the area of mandibular canines and first molars. Impressions (N=60) were made from the master cast using the 6 techniques investigated: group B-OC-N with occlusal registration impression material (B), open custom tray (OC), and nonsplinted impression pins (N); group B-OS-N with occlusal registration impression material (B), open plastic perforated stock tray (OS), and nonsplinted impression pins (N); group PE-OC-N with polyether medium-body impression material (PE), open custom tray (OC), and nonsplinted impression pins (N); group PE-OC-S with polyether medium-body impression material (PE), open custom tray (OC), and impression pins splinted (S)with autopolymerizing resin cut after 17 minutes and reconnected; group PE-CC-N with polyether medium-body impression material (PE), closed custom tray (CC), and nonsplinted impression pins (N); group PVS-CS-N with simultaneous double-mix polyvinyl siloxane impression material (PVS), closed stock perforated metal tray (CS), and nonsplinted impression pins (N). Type IV gypsum casts were fabricated 24 hours after making the impressions. A computerized numerical control 3D coordinate measuring machine was used to measure the absolute differences of the distances between the centroids of the 4 implants among the casts produced and the distances measured at the master cast. The Kruskal-Wallis test was used to determine differences among the experimental groups (alpha=.05). The Mann-Whitney U post hoc analysis was used for all group combinations. Results. No significant differences were found between the test groups B-OC-N and PE-OC-S, which were more accurate than the other groups. Group B-OS-N resulted in the least accurate impressions of all experimental groups. Group PE-OC-S resulted in more accurate impressions than the PE-OC-N group. No statistically significant differences were found between groups PE-OC-N and PE-CC-N or between groups PVS-CS-N and PE-CC-N. Conclusions. For complete edentulism, the use of silicone occlusal registration material with an open custom tray and nonsplinted impression pins resulted in impressions as accurate as those produced with PE open custom tray with splinted impression pins. These 2 techniques resulted in more accurate impressions than the other 4 techniques studied.
引用
收藏
页码:143 / 148
页数:6
相关论文
共 50 条
  • [1] Accuracy of a new elastomeric impression material for complete-arch dental implant impressions
    Baig, Mirza R.
    Buzayan, Muaiyed M.
    Yunus, Norsiah
    [J]. JOURNAL OF INVESTIGATIVE AND CLINICAL DENTISTRY, 2018, 9 (02) : e12320
  • [2] Assessment of impression material accuracy in complete-arch restorations on four implants
    Baldissara, Paolo
    Koci, Brunilda
    Messias, Aion Mangino
    Meneghello, Roberto
    Ghelli, Francesco
    Gatto, Maria Rosaria
    Ciocca, Leonardo
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2021, 126 (06): : 763 - 771
  • [3] Influence of implant scanbody material, position and operator on the accuracy of digital impression for complete-arch: A randomized in vitro trial
    Arcuri, Lorenzo
    Pozzi, Alessandro
    Lio, Fabrizio
    Rompen, Eric
    Zechner, Werner
    Nardi, Alessandra
    [J]. JOURNAL OF PROSTHODONTIC RESEARCH, 2020, 64 (02) : 128 - 136
  • [4] Accuracy of complete-arch digital implant impression with or without scanbody splinting: An in vitro study
    Pozzi, Alessandro
    Arcuri, Lorenzo
    Lio, Fabrizio
    Papa, Andrea
    Nardi, Alessandra
    Londono, Jimmy
    [J]. JOURNAL OF DENTISTRY, 2022, 119
  • [5] Influence of Implant Scanbody Wear on the Accuracy of Digital Impression for Complete-Arch: A Randomized In Vitro Trial
    Arcuri, Lorenzo
    Lio, Fabrizio
    Campana, Veronica
    Mazzetti, Vincenzo
    Federici, Francesca Romana
    Nardi, Alessandra
    Galli, Massimo
    [J]. MATERIALS, 2022, 15 (03)
  • [6] ACCURACY OF IMPRESSION MATERIALS FOR COMPLETE-ARCH FIXED PARTIAL DENTURES
    LIN, CC
    ZIEBERT, GJ
    DONEGAN, SJ
    DHURU, VB
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 1988, 59 (03): : 288 - 291
  • [7] AN IN VITRO COMPARISON OF PHOTOGRAMMETRIC AND CONVENTIONAL COMPLETE-ARCH IMPLANT IMPRESSION TECHNIQUES
    Bergin, Junping Ma
    Rubenstein, Jeffrey E.
    Mancl, Lloyd
    Brudvik, James S.
    Raigrodski, Ariel J.
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2013, 110 (04): : 243 - 251
  • [8] Accuracy of intraoral optical scan versus stereophotogrammetry for complete-arch digital implant impression: An in vitro study
    Pozzi, Alessandro
    Agliardi, Enrico
    Lio, Fabrizio
    Nagy, Katalin
    Nardi, Alessandra
    Arcuri, Lorenzo
    [J]. JOURNAL OF PROSTHODONTIC RESEARCH, 2024, 68 (01) : 172 - 180
  • [9] Accuracy of photogrammetry, intraoral scanning, and conventional impression techniques for complete-arch implant rehabilitation: an in vitro comparative study
    Bowen Ma
    Xinxin Yue
    Yujie Sun
    Lingyan Peng
    Wei Geng
    [J]. BMC Oral Health, 21
  • [10] Accuracy of complete-arch digital implant impression with intraoral optical scanning and stereophotogrammetry: An in vivo prospective comparative study
    Pozzi, Alessandro
    Carosi, Paolo
    Gallucci, German O.
    Nagy, Katalin
    Nardi, Alessandra
    Arcuri, Lorenzo
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2023, 34 (10) : 1106 - 1117