Impact of different scanning strategies on the accuracy of two current intraoral scanning systems in complete-arch impressions: an in vitro study

被引:3
|
作者
Passos, Leandro [1 ,2 ]
Meiga, Sergio
Brigagao, Vinicius [3 ]
Street, Alexandre [4 ]
机构
[1] Fed Fluminense Univ, Sch Dent, Hlth Inst Nova Friburgo, Dept Prosthet Dent, Rua Doutor Silvio Henrique Braune 22, BR-28625650 Nova Friburgo, RJ, Brazil
[2] Univ Alberta, Edmonton Clin Hlth Acad, Dept Dent, Edmonton, AB, Canada
[3] Grande Rio Univ, Sch Dent, Dept Prosthodont, Rio De Janeiro, Brazil
[4] Pontifical Catholic Univ Rio de Janeiro, Sch Engn, Elect Engn Dept, Rio De Janeiro, Brazil
关键词
CAD/CAM; intraoral scanner; digital impression; accuracy; full-arch dental impression; standard tessellation language; PRECISION; SCANNERS;
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Aim: To determine the scanning strategy that obtains the most accurate results for two intraoral scanners (IOS) in complete-arch digital impressions. Scan time was evaluated and correlated with scan strategies. Materials and method: A custom model used as the reference standard was fabricated with teeth having dentin- and enamel-identical refractive indices simulating natural dentition. A reference scan of the custom typodont was obtained using an ATOS III Triple Scan 3D optical scanner. Two IOS setups - Omnicam v 5.1.0 and Primescan v 5.0.2 - were used for complete-arch scanning, each using 13 scanning strategies, obtaining 260 digital files (n = 10 per group), recording each scan time, converting all experimental scans to standard tessellation language (STL) format, and using a comprehensive metrology program to compare the reference standard scan with the experimental scans. Statistical analyses utilized Welch's unequal variances t test. Results: Group M exhibited the lowest trueness and precision values (P < 0.05) for Primescan (47.5% of the average among all other groups) and the lowest trueness value (P < 0.05) for Omnicam (53.4% of the average among all other groups), where group B exhibited the lowest precision value (65.6% of the average among all other groups) with P <0.05. Primescan featured a better trueness index (4.79 mu m) than that of Omnicam (19.13 mu m), with a statistically significant difference (P < 0.00001). Primescan, group M, also featured a better precision index (4.67 mu m) than Omnicam, group B (16.75 mu m), with a statistically significant difference (P < 0.00001). Conclusion: For both IOS systems, group M provided the lowest scanning times. For trueness and precision of complete-arch scans, group M was the dominant scanning strategy in Primescan, while there was no dominant strategy in Omnicam. Group M had the best scanning time for both IOS systems.
引用
收藏
页码:307 / 319
页数:13
相关论文
共 50 条
  • [1] Accuracy of complete- and partial-arch impressions of actual intraoral scanning systems in vitro
    Ender, A.
    Zimmermann, M.
    Mehl, A.
    [J]. INTERNATIONAL JOURNAL OF COMPUTERIZED DENTISTRY, 2019, 22 (01) : 11 - 19
  • [2] Evaluating the influence of palate scanning on the accuracy of complete-arch digital impressions-An in vitro study
    Schmalzl, Judit
    Keskeny, Gyorgy Arpad
    Hermann, Peter
    Pal, Adrienn
    Geczi, Zoltan
    Borbely, Judit
    Roth, Ivett
    [J]. JOURNAL OF DENTISTRY, 2024, 145
  • [3] Accuracy of photogrammetry, intraoral scanning, and conventional impression techniques for complete-arch implant rehabilitation: an in vitro comparative study
    Bowen Ma
    Xinxin Yue
    Yujie Sun
    Lingyan Peng
    Wei Geng
    [J]. BMC Oral Health, 21
  • [4] Accuracy of photogrammetry, intraoral scanning, and conventional impression techniques for complete-arch implant rehabilitation: an in vitro comparative study
    Ma, Bowen
    Yue, Xinxin
    Sun, Yujie
    Peng, Lingyan
    Geng, Wei
    [J]. BMC ORAL HEALTH, 2021, 21 (01)
  • [5] A novel post-processing strategy to improve the accuracy of complete-arch intraoral scanning for implants: an in vitro study
    Pan, Yu
    Dai, Xuanyi
    Wan, Fang
    Song, Chaoyang
    Tsoi, James K. H.
    Pow, Edmond H. N.
    [J]. JOURNAL OF DENTISTRY, 2023, 139
  • [6] Influence of rescanning mesh holes and stitching procedures on the complete-arch scanning accuracy of an intraoral scanner: An in vitro study
    Gomez-Polo, Miguel
    Piedra-Cascon, Wenceslao
    Methani, Mohammed M.
    Quesada-Olmo, Nieves
    Farjas-Abadia, Mercedes
    Revilla-Leon, Marta
    [J]. JOURNAL OF DENTISTRY, 2021, 110
  • [7] Impact of scanning strategy on the accuracy of complete-arch intraoral scans: a preliminary study on segmental scans and merge methods
    Mai, Hai Yen
    Mai, Hang-Nga
    Lee, Cheong-Hee
    Lee, Kyu-Bok
    Kim, So-yeun
    Lee, Jae-Mok
    Lee, Keun-Woo
    Lee, Du-Hyeong
    [J]. JOURNAL OF ADVANCED PROSTHODONTICS, 2022, 14 (02): : 88 - 95
  • [8] Accuracy of four digital scanners according to scanning strategy in complete-arch impressions
    Medina-Sotomayor, Priscilla
    Pascual M., Agustin
    Camps A., Isabel
    [J]. PLOS ONE, 2018, 13 (09):
  • [9] Complete-Arch Accuracy of Four Intraoral Scanners: An In Vitro Study
    Celeghin, Giordano
    Franceschetti, Giulio
    Mobilio, Nicola
    Fasiol, Alberto
    Catapano, Santo
    Corsalini, Massimo
    Grande, Francesco
    [J]. HEALTHCARE, 2021, 9 (03)
  • [10] Influence of arch location and scanning pattern on the scanning accuracy, scanning time, and number of photograms of complete-arch intraoral digital implant scans
    Gomez-Polo, Miguel
    Cascos, Rocio
    Ortega, Rocio
    Barmak, Abdul B.
    Kois, John C.
    Revilla-Leon, Marta
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2023, 34 (06) : 591 - 601