A novel post-processing strategy to improve the accuracy of complete-arch intraoral scanning for implants: an in vitro study

被引:1
|
作者
Pan, Yu [1 ]
Dai, Xuanyi [1 ]
Wan, Fang [2 ]
Song, Chaoyang [3 ]
Tsoi, James K. H. [4 ]
Pow, Edmond H. N. [4 ]
机构
[1] Southern Univ Sci & Technol, Jinan Univ, Shenzhen Peoples Hosp, Dept Dent,Affiliated Hosp 1,Clin Med Coll 2, Shenzhen, Guangdong, Peoples R China
[2] Southern Univ Sci & Technol, Sch Design, Shenzhen, Guangdong, Peoples R China
[3] Southern Univ Sci & Technol, Dept Mech & Energy Engn, Shenzhen, Guangdong, Peoples R China
[4] Univ Hong Kong, Prince Philip Dent Hosp, Fac Dent, 34 Hosp Rd, Hong Kong, Peoples R China
关键词
Computer -aided design; Dimensional measurement accuracy; 3-D imaging; Dental implants; Edentulous; UNDERSTANDING DENTAL CAD/CAM; RESTORATIONS; IMPRESSIONS;
D O I
10.1016/j.jdent.2023.104761
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: To develop a new post-processing strategy that utilizes an auxiliary device to adjust intraoral scans and improve the accuracy of 3D models of complete-arch dental implants. Materials and methods: An edentulous resin model with 6 dental implants was prepared. An auxiliary device, consisting of an opaque base and artificial landmarks, was fabricated and mounted onto the resin model. Twenty intraoral scans (raw scans) were taken using this setup. A new post-processing strategy was proposed to adjust the raw scans using reverse engineering software (verified group). Additionally, ten conventional gypsum casts were duplicated and digitized using a laboratory scanner. The linear and angular trueness and precision of the models were evaluated and compared. The effect of the proposed strategy on the accuracy of complete-arch intraoral scans was analyzed using one-way ANOVA. Results: The linear trueness (29.7 mu m) and precision (24.8 mu m) of the verified group were significantly better than the raw scans (46.6 mu m, 44.7 mu m) and conventional casts (51.3 mu m, 36.5 mu m), particularly in cross-arch sites. However, the angular trueness (0.114 degrees) and precision (0.085 degrees) of the conventional casts were significantly better than both the verified models (0.298 degrees, 0.168 degrees) and the raw scans (0.288 degrees, 0.202 degrees). Conclusions: The novel post-processing strategy is effective in enhancing the linear accuracy of complete-arch implant IO scans, especially in cross-arch sites. However, further improvement is needed to eliminate the angular deviations. Clinical significance: Errors generated from intraoral scanning in complete edentulous arches exceed the clinical threshold. The elimination of stitching errors in the raw scans particularly in the cross-arch sites, through the proposed post-processing strategy would enhance the accuracy of complete-arch implant prostheses.
引用
收藏
页数:8
相关论文
共 47 条
  • [1] Complete-Arch Accuracy of Four Intraoral Scanners: An In Vitro Study
    Celeghin, Giordano
    Franceschetti, Giulio
    Mobilio, Nicola
    Fasiol, Alberto
    Catapano, Santo
    Corsalini, Massimo
    Grande, Francesco
    [J]. HEALTHCARE, 2021, 9 (03)
  • [2] Effect of novel prefabricated auxiliary devices attaching to scan bodies on the accuracy of intraoral scanning of complete-arch with multiple implants: An in-vitro study
    Wu, Hio Kuan
    Wang, Jing
    Chen, Guanhui
    Huang, Xiaoqiong
    Deng, Feilong
    Li, Yiming
    [J]. JOURNAL OF DENTISTRY, 2023, 138
  • [3] Impact of different scanning strategies on the accuracy of two current intraoral scanning systems in complete-arch impressions: an in vitro study
    Passos, Leandro
    Meiga, Sergio
    Brigagao, Vinicius
    Street, Alexandre
    [J]. INTERNATIONAL JOURNAL OF COMPUTERIZED DENTISTRY, 2019, 22 (04) : 307 - 319
  • [4] Accuracy of complete-arch model using an intraoral video scanner: An in vitro study
    Jeong, Ii-Do
    Lee, Jae-Jun
    Jeon, Jin-Hun
    Kim, Ji-Hwan
    Kim, Hae-Young
    Kim, Woong-Chul
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2016, 115 (06): : 755 - 759
  • [5] Impact of scanning strategy on the accuracy of complete-arch intraoral scans: a preliminary study on segmental scans and merge methods
    Mai, Hai Yen
    Mai, Hang-Nga
    Lee, Cheong-Hee
    Lee, Kyu-Bok
    Kim, So-yeun
    Lee, Jae-Mok
    Lee, Keun-Woo
    Lee, Du-Hyeong
    [J]. JOURNAL OF ADVANCED PROSTHODONTICS, 2022, 14 (02): : 88 - 95
  • [6] Accuracy of photogrammetry, intraoral scanning, and conventional impression techniques for complete-arch implant rehabilitation: an in vitro comparative study
    Bowen Ma
    Xinxin Yue
    Yujie Sun
    Lingyan Peng
    Wei Geng
    [J]. BMC Oral Health, 21
  • [7] Accuracy of photogrammetry, intraoral scanning, and conventional impression techniques for complete-arch implant rehabilitation: an in vitro comparative study
    Ma, Bowen
    Yue, Xinxin
    Sun, Yujie
    Peng, Lingyan
    Geng, Wei
    [J]. BMC ORAL HEALTH, 2021, 21 (01)
  • [8] Influence of rescanning mesh holes and stitching procedures on the complete-arch scanning accuracy of an intraoral scanner: An in vitro study
    Gomez-Polo, Miguel
    Piedra-Cascon, Wenceslao
    Methani, Mohammed M.
    Quesada-Olmo, Nieves
    Farjas-Abadia, Mercedes
    Revilla-Leon, Marta
    [J]. JOURNAL OF DENTISTRY, 2021, 110
  • [9] Accuracy of six intraoral scanners for scanning complete-arch and 4-unit fixed partial dentures: An in vitro study
    Diker, Burcu
    Tak, Onjen
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2022, 128 (02): : 187 - 194
  • [10] Influence of scanning protocol on the accuracy of complete-arch digital implant scans: An in vitro study
    Hamilton, Adam
    Negreiros, William Matthew
    Jain, Shruti
    Finkelman, Matthew
    Gallucci, German O.
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2024, 35 (06) : 641 - 651