Accuracy of complete- and partial-arch impressions of actual intraoral scanning systems in vitro

被引:6
|
作者
Ender, A. [1 ]
Zimmermann, M. [1 ]
Mehl, A. [1 ]
机构
[1] Univ Zurich, Ctr Dent Med, Clin Prevent Dent Periodontol & Cariol, Div Computerized Restorat Dent, Zurich, Switzerland
关键词
intraoral scanner; digital impression; conventional impression; accuracy; precision; trueness; DIGITAL IMPRESSIONS; VIVO PRECISION; SCANNERS; EFFICIENCY;
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective: Intraoral scanners (IOSs) are widely used for obtaining digital dental models directly from the patient. Additionally, improvements in IOSs are made from generation to generation. The aim of this study was to evaluate the accuracy of new and actual IOS devices for complete-and partial-arch dental impressions in an in vitro setup. Materials and methods: A custom maxillary complete-arch cast with teeth made from feldspar ceramic material was used as the reference cast and digitized with a reference scanner (ATOS III Triple Scan MV60). One conventional impression technique using polyvinylsiloxane (PVS) material (President) served as the control (CO), and eight different IOS devices comprising different hardware and software configurations (TRn: Trios 3; TRi: Trios 3 insane; CS: Carestream Dental CS 3600; MD: Medit i500; iT: iTero Element 2; OC4: Cerec Omnicam 4.6.1; OC5: Cerec Omnicam 5.0.0; PS: Primescan) were used to take complete-arch impressions from the reference cast. The impressions were repeated 10 times (n = 10) for each group. Conventional impressions were poured with type IV gypsum and digitized with a laboratory scanner (inEos X5). All datasets were obtained in standard tessellation language (STL) file format and cut to either complete-arch, anterior segment, or posterior segment areas for respective analysis. Values for trueness and precision for the respective areas were evaluated using a three-dimensional (3D) superimposition method with special 3D difference analysis software (GOM Inspect) using (90-10)/2 percentile values. Statistical analysis was performed using either one-way analysis of variance (ANOVA) or Kruskal-Wallis test (a = 0.05). Results are given as median and interquartile range [IQR] values in mu m. Results: Statistically significant differences were found between test groups for complete-and partial-arch impression methods in vitro (p < 0.05). Values ranged from 16.3 [2.8] mu m (CO) up to 89.8 [26.1] mu m (OC4) for in vitro trueness, and from 10.6 [3.8] mu m (CO) up to 58.6 [38.4] mu m (iT) for in vitro precision for the complete-arch methods. The best values for trueness of partial-arch impressions were found for the posterior segment, with 9.7 [1.2] mu m for the conventional impression method (CO), and 21.9 [1.5] mu m (PS) for the digital impression method. Conclusion: Within the limitations of this study, digital impressions obtained from specific IOSs are a valid alternative to conventional impressions for partial-arch segments. Complete-arch impressions are still challenging for IOS devices; however, certain devices were shown to be well within the required range for clinical quality. Further in vivo studies are needed to support these results.
引用
收藏
页码:11 / 19
页数:9
相关论文
共 50 条
  • [1] Impact of different scanning strategies on the accuracy of two current intraoral scanning systems in complete-arch impressions: an in vitro study
    Passos, Leandro
    Meiga, Sergio
    Brigagao, Vinicius
    Street, Alexandre
    [J]. INTERNATIONAL JOURNAL OF COMPUTERIZED DENTISTRY, 2019, 22 (04) : 307 - 319
  • [2] Accuracy of six intraoral scanners for scanning complete-arch and 4-unit fixed partial dentures: An in vitro study
    Diker, Burcu
    Tak, Onjen
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2022, 128 (02): : 187 - 194
  • [3] Local accuracy of actual intraoral scanning systems for single-tooth preparations in vitro
    Zimmermann, Moritz
    Ender, Andreas
    Mehl, Albert
    [J]. JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 2020, 151 (02): : 127 - 135
  • [4] Evaluating the influence of palate scanning on the accuracy of complete-arch digital impressions-An in vitro study
    Schmalzl, Judit
    Keskeny, Gyorgy Arpad
    Hermann, Peter
    Pal, Adrienn
    Geczi, Zoltan
    Borbely, Judit
    Roth, Ivett
    [J]. JOURNAL OF DENTISTRY, 2024, 145
  • [5] Complete-Arch Accuracy of Four Intraoral Scanners: An In Vitro Study
    Celeghin, Giordano
    Franceschetti, Giulio
    Mobilio, Nicola
    Fasiol, Alberto
    Catapano, Santo
    Corsalini, Massimo
    Grande, Francesco
    [J]. HEALTHCARE, 2021, 9 (03)
  • [6] Influence of intraoral scanning coverage on the accuracy of digital implant impressions - An in vitro study
    Wang, Zhen-yu
    Gong, Yu
    Liu, Fei
    Chen, Du
    Shen, Jie-fei
    [J]. JOURNAL OF DENTISTRY, 2024, 143
  • [7] Accuracy of intraoral scanning versus conventional impressions for partial edentulous patients with maxillary defects
    Rongkai Cao
    Shilei Zhang
    Lishan Li
    Piaopiao Qiu
    Hui Xu
    Yujie Cao
    [J]. Scientific Reports, 13
  • [8] Accuracy of intraoral scanning versus conventional impressions for partial edentulous patients with maxillary defects
    Cao, Rongkai
    Zhang, Shilei
    Li, Lishan
    Qiu, Piaopiao
    Xu, Hui
    Cao, Yujie
    [J]. SCIENTIFIC REPORTS, 2023, 13 (01)
  • [9] Learning curve of digital intraoral optical scanning for complete arch: an in vitro study
    Lio, F.
    Carosi, P.
    Mazzetti, V
    Arcuri, C.
    [J]. JOURNAL OF BIOLOGICAL REGULATORS AND HOMEOSTATIC AGENTS, 2022, 36 (02): : 19 - 27
  • [10] Complete-arch accuracy of intraoral scanners
    Treesh, Joshua C.
    Liacouras, Peter C.
    Taft, Robert M.
    Brooks, Daniel, I
    Raiciulescu, Sorana
    Ellert, Daniel O.
    Grant, Gerald T.
    Ye, Ling
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2018, 120 (03): : 382 - 388