Evaluating the influence of palate scanning on the accuracy of complete-arch digital impressions-An in vitro study

被引:1
|
作者
Schmalzl, Judit [1 ,2 ]
Keskeny, Gyorgy Arpad [2 ]
Hermann, Peter [1 ]
Pal, Adrienn [1 ,2 ]
Geczi, Zoltan [1 ]
Borbely, Judit [1 ]
Roth, Ivett [1 ]
机构
[1] Semmelweis Univ, Dept Prosthodont, Szentkiralyi St 47, H-1088 Budapest, Hungary
[2] Semmelweis Univ, Sch PhD Studies, Ulloi U 26, H-1085 Budapest, Hungary
来源
JOURNAL OF DENTISTRY | 2024年 / 145卷
关键词
Comlete-arch digital scan; Palatal area; Accuracy; Palate scanning; INTRAORAL SCANNERS; PRECISION; TRUENESS; SYSTEMS;
D O I
10.1016/j.jdent.2024.105014
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: To assess the impact of including the palate and the number of images recorded during intraoral digital scanning procedure on the accuracy of complete arch scans. Methods: An experienced operator conducted 40 digital scans of a 3D printed maxillary model and divided them into two groups: 20 with inclusion of the palate (PAL) and 20 without (NPAL). Each set of scans was performed using an intraoral scanner (IOS) (Trios 5; 3Shape A/S; Copenhagen, Denmark). The resulting STL files were imported into the Geomagic Control X software (3D Systems, Rock Hill, SC, USA) for accuracy comparison. A reference STL file was created using a 3Shape E3 laboratory scanner (3Shape Scanlt Dental 2.2.1.0; Copenhagen, Denmark). The number of images captured was recorded during the scanning procedure. Results: In the case of the right side no statistically significant difference in trueness was detected (84 mu m +/- 45.6 for PAL and 80.4 +/- 40.4 mu m for NPAL). In the case of the left side no significant difference in trueness was observed (215.1 +/- 70.2 mu m for PAL and 233.9 +/- 70.7 mu m for NPAL). In the case of the arch distortion a statistically significant difference in trueness was seen between the two types of scans (135.3 +/- 71.9 mu m for PAL and 380.4 +/- 255.1 mu m for NPAL). The average number of images was 831.25, and 593.8 for PAL and NPAL, respectively. Conclusions: Scanning of the palatal area can significantly improve the accuracy of dental scans in cases of complete arches. In terms of the number of images, based on the current results, obvious conclusions could not be drawn, and further investigation is required. Clinical significance: Scanning the palate may be beneficial for improving the accuracy of intraoral scans in dentate patients. Consequently, this should be linked to an appropriate scanning strategy that predicts palatal scanning.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Influence of scanning protocol on the accuracy of complete-arch digital implant scans: An in vitro study
    Hamilton, Adam
    Negreiros, William Matthew
    Jain, Shruti
    Finkelman, Matthew
    Gallucci, German O.
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2024, 35 (06) : 641 - 651
  • [2] Accuracy of four digital scanners according to scanning strategy in complete-arch impressions
    Medina-Sotomayor, Priscilla
    Pascual M., Agustin
    Camps A., Isabel
    [J]. PLOS ONE, 2018, 13 (09):
  • [3] Impact of different scanning strategies on the accuracy of two current intraoral scanning systems in complete-arch impressions: an in vitro study
    Passos, Leandro
    Meiga, Sergio
    Brigagao, Vinicius
    Street, Alexandre
    [J]. INTERNATIONAL JOURNAL OF COMPUTERIZED DENTISTRY, 2019, 22 (04) : 307 - 319
  • [4] Effect of prefabricated auxiliary devices and scanning patterns on the accuracy of complete-arch implant digital impressions
    Wu, Hio Kuan
    Chen, Guanhui
    Wang, Jing
    Zhang, Zhengchuan
    Huang, Xiaoqiong
    Lin, Xiaoxuan
    Deng, Feilong
    Li, Yiming
    [J]. JOURNAL OF DENTISTRY, 2024, 140
  • [5] Accuracy of three digital scanning methods for complete-arch tooth preparation: An in vitro comparison
    Gao, Hanqi
    Liu, Xiaoqiang
    Liu, Mingyue
    Yang, Xu
    Tan, Jianguo
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2022, 128 (05): : 1001 - 1008
  • [6] A clinical pilot study of the dimensional accuracy of double-arch and complete-arch impressions
    Cox, JR
    Brandt, RL
    Hughes, HJ
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2002, 87 (05): : 510 - 515
  • [7] Accuracy of digital impressions for implant-supported complete-arch prosthesis, using an auxiliary geometry part-An in vitro study
    Iturrate, Mikel
    Eguiraun, Harkaitz
    Solaberrieta, Eneko
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2019, 30 (12) : 1250 - 1258
  • [8] Influence of arch location and scanning pattern on the scanning accuracy, scanning time, and number of photograms of complete-arch intraoral digital implant scans
    Gomez-Polo, Miguel
    Cascos, Rocio
    Ortega, Rocio
    Barmak, Abdul B.
    Kois, John C.
    Revilla-Leon, Marta
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2023, 34 (06) : 591 - 601
  • [9] The effect of scanning the palate and scan body position on the accuracy of complete-arch implant scans
    Mizumoto, Ryan M.
    Alp, Gulce
    Ozcan, Mutlu
    Yilmaz, Burak
    [J]. CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2019, 21 (05) : 987 - 994
  • [10] Influence of rescanning mesh holes and stitching procedures on the complete-arch scanning accuracy of an intraoral scanner: An in vitro study
    Gomez-Polo, Miguel
    Piedra-Cascon, Wenceslao
    Methani, Mohammed M.
    Quesada-Olmo, Nieves
    Farjas-Abadia, Mercedes
    Revilla-Leon, Marta
    [J]. JOURNAL OF DENTISTRY, 2021, 110