Effect of additional reference objects on accuracy of five intraoral scanners in partially and completely edentulous jaws: An in vitro study

被引:11
|
作者
Rutkunas, Vygandas [1 ,8 ]
Gedrimiene, Agne [1 ]
Husain, Nadin Al-Haj [2 ,3 ]
Pletkus, Justinas [4 ]
Barauskis, Dainius [5 ]
Jegelevicius, Darius [6 ,7 ]
Ozcan, Mutlu [2 ]
机构
[1] Vilnius Univ, Inst Odontol, Fac Med, Dept Prosthodont, Vilnius, Lithuania
[2] Univ Zurich, Ctr Dent Med, Div Dent Biomat, Clin Reconstruct Dent, Zurich, Switzerland
[3] Univ Bern, Sch Dent Med, Dept Reconstruct Dent & Gerodontol, Bern, Switzerland
[4] Vilnius Univ, Inst Odontol, Med Fac, Vilnius, Lithuania
[5] Kaunas Univ Technol, Biomed Engn Inst, Kaunas, Lithuania
[6] Kaunas Univ Technol, Biomed Engn Inst, Kaunas, Lithuania
[7] Kaunas Univ Technol, Fac Elect & Elect Engn, Kaunas, Lithuania
[8] Vilnius Univ, Inst Odontol, Fac Med, Dept Prosthodont, Zalgirio str 115, LT-08217 Vilnius, Lithuania
来源
JOURNAL OF PROSTHETIC DENTISTRY | 2023年 / 130卷 / 01期
关键词
IMPRESSIONS; PRECISION; MAXILLA;
D O I
10.1016/j.prosdent.2021.09.032
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. The effect of additional reference objects on the accuracy of different intraoral scanners for partially and completely edentulous patients has not been investigated sufficiently.Purpose. The purpose of this in vitro study was to evaluate the effect of an additional reference object in the form of additional artificial landmarks on the trueness and precision of different intraoral scanners in partially and completely edentulous areas.Material and methods. Partially and completely edentulous models with 2 and 4 implants (BLT, RC, Institut Straumann AG), respectively, were used in the study. For the digital scan, scan bodies (CARES Mono Scanbody) were attached, and reference data obtained by using industrial scanners. Ten digital scans of the same model were made with each intraoral scanner: PRIMESCAN, TRIOS 3, TRIOS 4, Carestream 3600, and Medit. Then, additional artificial landmarks were attached, and 10 more intraoral scans were made with each device. Computer-aided design files of the scan bodies were aligned to obtain 3-dimensional surfaces with reference and test scanners. Trueness and precision of distance, angulations, and vertical shift between scan bodies were estimated. The Mann-Whitney Wilcoxon or Student 2-sample t test was applied to estimate statistically significant differences between groups (a=.05).Results. In the partially edentulous model, distance trueness mean & PLUSMN;standard deviation values ranged from -46.7 & PLUSMN;15.4 gm (TRIOS 3) to 392.1 & PLUSMN;314.3 gm (Medit) in models without additional artificial landmarks. When additional artificial landmarks were applied, trueness of distance mean & PLUSMN;standard deviation values ranged between -35 & PLUSMN;13 gm (TRIOS 4) and 117.7 & PLUSMN;232.3 gm (CARESTREAM). Trueness mean & PLUSMN;standard deviation values of angulation varied from -0.0 & PLUSMN;0.5 degrees (CARESTREAM) to 0.2 & PLUSMN;0.0 degrees (PRIMESCAN) without additional artificial landmarks and from 0.0 & PLUSMN;0.2 degrees (TRIOS 3) to 0.4 & PLUSMN;0.5 degrees (CARESTREAM) with additional artificial landmarks. Vertical shift trueness measurements varied from -108 & PLUSMN;47.1 gm (TRIOS 4) to 107.2 & PLUSMN;103.5 gm (Medit) without additional artificial landmarks and from -15.0 & PLUSMN;45.0 gm (CARESTREAM) to -86.9 & PLUSMN;42.1 gm (TRIOS 4) with additional artificial landmarks. The additional artificial landmark technique improved the trueness of all measured parameters for the 5 tested intraoral scanners. No statistically significant differences were found among models with or without additional artificial landmarks, except for Medit in all parameters and PRIMESCAN in angle measurements (P<.05). The best precision for distance was found with TRIOS 3 and with PRIMESCAN for angulation and vertical shift. Larger deviations were observed in the completely edentulous situation. The effect of additional artificial landmarks was limited when the accuracy parameters of digital scans were considered.Conclusions. Scans with and without additional artificial landmarks of partially edentulous conditions scanned by any of the intraoral scanners tested did not influence precision and trueness, except for Medit i500 in the distance and vertical shift parameters and CARESTREAM3600 in vertical shift. Precision and trueness of digital scans of completely edentulous areas were affected, except for Medit i500 for distance, PRIMESCAN and TRIOS 4 for angle, and all systems except TRIOS 4 for vertical shift precision. (J Prosthet Dent 2023;130:111-8)
引用
收藏
页码:111 / 118
页数:8
相关论文
共 50 条
  • [21] Effect of different preparation designs of minimally invasive occlusal onlays on the accuracy of different intraoral scanners: An in vitro study
    Ashraf, Khadija
    Ebeid, Kamal
    Salah, Tarek
    [J]. JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2023,
  • [22] Effect of scanning strategies on the accuracy of digital intraoral scanners: a meta-analysis of in vitro studies
    Hardan, Louis
    Bourgi, Rim
    Lukomska-Szymanska, Monika
    Hernandez-Cabanillas, Juan Carlos
    Zamarripa-Calderon, Juan Eliezer
    Jorquera, Gilbert
    Ghishan, Sinan
    Cuevas-Suarez, Carlos Enrique
    [J]. JOURNAL OF ADVANCED PROSTHODONTICS, 2023, 15 (06): : 315 - 332
  • [23] Accuracy of a chairside intraoral scanner compared with a laboratory scanner for the completely edentulous maxilla: An in vitro 3-dimensional comparative analysis
    Zarone, Fernando
    Ruggiero, Gennaro
    Ferrari, Marco
    Mangano, Francesco
    Joda, Tim
    Sorrentino, Roberto
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2020, 124 (06): : 761.e1 - 761.e7
  • [24] Influence of scan technology on the accuracy and speed of intraoral scanning systems for the edentulous maxilla: An in vitro study
    Osman, Reham Bassuni
    Alharbi, Nawal Murshed
    [J]. JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2023, 32 (09): : 821 - 828
  • [25] Accuracy evaluation of two different intraoral scanners in implant prosthodontics. A comparative in vitro study
    Verniani, G.
    Casucci, A.
    Nosrati, N.
    D'Arienzo, L. F.
    Val, M.
    Cagidiaco, E. Ferrari
    [J]. JOURNAL OF OSSEOINTEGRATION, 2024, 16 (01) : 61 - 64
  • [26] Accuracy of 14 intraoral scanners for the All-on-4 treatment concept: a comparative in vitro study
    Kaya, Gozde
    Bilmenoglu, Caglar
    [J]. JOURNAL OF ADVANCED PROSTHODONTICS, 2022, 14 (06): : 388 - 398
  • [27] Effects of different types of intraoral scanners and scanning ranges on the precision of digital implant impressions in edentulous maxilla: An in vitro study
    Miyoshi, Keita
    Tanaka, Shinpei
    Yokoyama, Sawako
    Sanda, Minoru
    Baba, Kazuyoshi
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2020, 31 (01) : 74 - 83
  • [28] Accuracy of static fully guided implant placement in the posterior area of partially edentulous jaws: a cohort prospective study
    Gargallo-Albiol, Jordi
    Jose Zilleruelo-Pozo, Maria
    Lucas-Taule, Ernest
    Munoz-Penalver, Jesus
    Paternostro-Betancourt, Daniel
    Hernandez-Alfaro, Federico
    [J]. CLINICAL ORAL INVESTIGATIONS, 2022, 26 (03) : 2783 - 2791
  • [29] Accuracy of static fully guided implant placement in the posterior area of partially edentulous jaws: a cohort prospective study
    Jordi Gargallo-Albiol
    María José Zilleruelo-Pozo
    Ernest Lucas-Taulé
    Jesús Muñoz-Peñalver
    Daniel Paternostro-Betancourt
    Federico Hernandez-Alfaro
    [J]. Clinical Oral Investigations, 2022, 26 : 2783 - 2791
  • [30] Accuracy of Computerized Optical Impression Making in Fabrication of Removable Dentures for Partially Edentulous Jaws: An In Vivo Feasibility Study
    Saravi, Babak
    Ilbertz, Julia
    Vach, Kirstin
    Kohal, Ralf J.
    Patzelt, Sebastian B. M.
    [J]. JOURNAL OF FUNCTIONAL BIOMATERIALS, 2023, 14 (09)