Accuracy of Computerized Optical Impression Making in Fabrication of Removable Dentures for Partially Edentulous Jaws: An In Vivo Feasibility Study

被引:0
|
作者
Saravi, Babak [1 ,2 ]
Ilbertz, Julia [3 ,4 ]
Vach, Kirstin [5 ]
Kohal, Ralf J. [3 ]
Patzelt, Sebastian B. M. [3 ,4 ]
机构
[1] Univ Freiburg, Med Ctr, Fac Med, Dept Orthoped & Trauma Surg, Hugstetter St 55, D-79106 Freiburg, Germany
[2] Harvard Med Sch, Brigham & Womens Hosp, Dept Anesthesiol Perioperat & Pain Med, Boston, MA 02115 USA
[3] Univ Freiburg, Med Ctr, Fac Med, Ctr Dent Med,Dept Prosthet Dent, Hugstetter St 55, D-79106 Freiburg, Germany
[4] Private Dent Clin, Dorfplatz 3, D-78658 Zimmern, Germany
[5] Univ Freiburg, Med Ctr, Inst Med Biometry & Stat, Fac Med, Stefan Meier Str 26, D-79104 Freiburg, Germany
关键词
intraoral scan; conventional impression; digital impression; partially edentulous; dental prosthesis; 3D analyses; INTRAORAL SCANNERS; TRUENESS; PRECISION;
D O I
10.3390/jfb14090458
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The use of computerized optical impression making (COIM) for the fabrication of removable dentures for partially edentulous jaws is a rising trend in dental prosthetics. However, the accuracy of this method compared with that of traditional impression-making techniques remains uncertain. We therefore decided to evaluate the accuracy of COIM in the context of partially edentulous jaws in an in vivo setting. Twelve partially edentulous patients with different Kennedy classes underwent both a conventional impression (CI) and a computerized optical impression (COI) procedure. The CI was then digitized and compared with the COI data using 3D analysis software. Four different comparison situations were assessed: Whole Jaw (WJ), Mucosa with Residual Teeth (M_RT), Isolated Mucosa (IM), and Isolated Abutment Teeth (AT). Statistical analyses were conducted to evaluate group differences by quantifying the deviation values between the CIs and COIs. The mean deviations between the COIs and CIs varied significantly across the different comparison situations, with mucosal areas showing higher deviations than dental hard tissue. However, no statistically significant difference was found between the maxilla and mandible. Although COIM offers a no-pressure impression method that captures surfaces without irritation, it was found to capture mucosa less accurately than dental hard tissue. This discrepancy can likely be attributed to software algorithms that automatically filter out mobile tissues. Clinically, these findings suggest that caution is required when using COIM for prosthetics involving mucosal tissues as deviations could compromise the fit and longevity of the prosthetic appliance. Further research is warranted to assess the clinical relevance of these deviations.
引用
收藏
页数:14
相关论文
共 19 条
  • [1] Computerized optical impression making of edentulous jaws - An in vivo feasibility study
    Hack, Gary
    Liberman, Leila
    Vach, Kirstin
    Tchorz, Joerg P.
    Kohal, Ralf J.
    Patzelt, Sebastian B. M.
    [J]. JOURNAL OF PROSTHODONTIC RESEARCH, 2020, 64 (04) : 444 - 453
  • [2] Computerized Optical Impression Making of Fully Dentate Upper and Lower Jaws: An In Vitro Study
    Droste, Lukas
    Vach, Kirstin
    Kohal, Ralf J.
    Patzelt, Sebastian B. M.
    [J]. APPLIED SCIENCES-BASEL, 2024, 14 (06):
  • [3] Intraoral optical impression versus conventional impression for fully edentulous maxilla: an in vivo comparative study
    Willmann, Claire
    Deschamps, Adrien
    Taddei-Gross, Corinne
    Musset, Anne-Marie
    Lai, Cecilia
    Etienne, Olivier
    [J]. INTERNATIONAL JOURNAL OF COMPUTERIZED DENTISTRY, 2024, 27 (01) : 19 - 26
  • [4] Accuracy of static fully guided implant placement in the posterior area of partially edentulous jaws: a cohort prospective study
    Gargallo-Albiol, Jordi
    Jose Zilleruelo-Pozo, Maria
    Lucas-Taule, Ernest
    Munoz-Penalver, Jesus
    Paternostro-Betancourt, Daniel
    Hernandez-Alfaro, Federico
    [J]. CLINICAL ORAL INVESTIGATIONS, 2022, 26 (03) : 2783 - 2791
  • [5] Accuracy of static fully guided implant placement in the posterior area of partially edentulous jaws: a cohort prospective study
    Jordi Gargallo-Albiol
    María José Zilleruelo-Pozo
    Ernest Lucas-Taulé
    Jesús Muñoz-Peñalver
    Daniel Paternostro-Betancourt
    Federico Hernandez-Alfaro
    [J]. Clinical Oral Investigations, 2022, 26 : 2783 - 2791
  • [6] Effect of additional reference objects on accuracy of five intraoral scanners in partially and completely edentulous jaws: An in vitro study
    Rutkunas, Vygandas
    Gedrimiene, Agne
    Husain, Nadin Al-Haj
    Pletkus, Justinas
    Barauskis, Dainius
    Jegelevicius, Darius
    Ozcan, Mutlu
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2023, 130 (01): : 111 - 118
  • [7] Digital assessment of preliminary impression accuracy for edentulous jaws: Comparisons of 3-dimensional surfaces between study and working casts
    Matsuda, Takashi
    Goto, Takaharu
    Kurahashi, Kosuke
    Kashiwabara, Toshiya
    Watanabe, Megumi
    Tomotake, Yoritoki
    Nagao, Kan
    Ichikawa, Tetsuo
    [J]. JOURNAL OF PROSTHODONTIC RESEARCH, 2016, 60 (03) : 206 - 212
  • [8] Accuracy of impression-making methods in edentulous arches: An in vitro study encompassing conventional and digital methods
    Li, Jiayi
    Moon, Hong Seok
    Kim, Jee-Hwan
    Yoon, Hyung-In
    Oh, Kyung Chul
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2022, 128 (03): : 479 - 486
  • [9] Correction to: Accuracy of full‑arch digitalization for partially edentulous jaws — a laboratory study on basis of coordinate‑based data analysis
    Panagiotis Kontis
    Jan‑Frederik Güth
    Christine Keul
    [J]. Clinical Oral Investigations, 2022, 26 : 3663 - 3663
  • [10] Comparison of the prognosis of the remaining teeth between implant-supported fixed prostheses and removable partial dentures in partially edentulous patients: A retrospective study
    Yamada, Ryo
    Nogawa, Toshifumi
    Takayama, Yoshiyuki
    Iwata, Kai
    Saito, Masayasu
    Yokoyama, Atsuro
    [J]. CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2022, 24 (01) : 83 - 93