Effect of additional reference objects on accuracy of five intraoral scanners in partially and completely edentulous jaws: An in vitro study

被引:11
|
作者
Rutkunas, Vygandas [1 ,8 ]
Gedrimiene, Agne [1 ]
Husain, Nadin Al-Haj [2 ,3 ]
Pletkus, Justinas [4 ]
Barauskis, Dainius [5 ]
Jegelevicius, Darius [6 ,7 ]
Ozcan, Mutlu [2 ]
机构
[1] Vilnius Univ, Inst Odontol, Fac Med, Dept Prosthodont, Vilnius, Lithuania
[2] Univ Zurich, Ctr Dent Med, Div Dent Biomat, Clin Reconstruct Dent, Zurich, Switzerland
[3] Univ Bern, Sch Dent Med, Dept Reconstruct Dent & Gerodontol, Bern, Switzerland
[4] Vilnius Univ, Inst Odontol, Med Fac, Vilnius, Lithuania
[5] Kaunas Univ Technol, Biomed Engn Inst, Kaunas, Lithuania
[6] Kaunas Univ Technol, Biomed Engn Inst, Kaunas, Lithuania
[7] Kaunas Univ Technol, Fac Elect & Elect Engn, Kaunas, Lithuania
[8] Vilnius Univ, Inst Odontol, Fac Med, Dept Prosthodont, Zalgirio str 115, LT-08217 Vilnius, Lithuania
来源
JOURNAL OF PROSTHETIC DENTISTRY | 2023年 / 130卷 / 01期
关键词
IMPRESSIONS; PRECISION; MAXILLA;
D O I
10.1016/j.prosdent.2021.09.032
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. The effect of additional reference objects on the accuracy of different intraoral scanners for partially and completely edentulous patients has not been investigated sufficiently.Purpose. The purpose of this in vitro study was to evaluate the effect of an additional reference object in the form of additional artificial landmarks on the trueness and precision of different intraoral scanners in partially and completely edentulous areas.Material and methods. Partially and completely edentulous models with 2 and 4 implants (BLT, RC, Institut Straumann AG), respectively, were used in the study. For the digital scan, scan bodies (CARES Mono Scanbody) were attached, and reference data obtained by using industrial scanners. Ten digital scans of the same model were made with each intraoral scanner: PRIMESCAN, TRIOS 3, TRIOS 4, Carestream 3600, and Medit. Then, additional artificial landmarks were attached, and 10 more intraoral scans were made with each device. Computer-aided design files of the scan bodies were aligned to obtain 3-dimensional surfaces with reference and test scanners. Trueness and precision of distance, angulations, and vertical shift between scan bodies were estimated. The Mann-Whitney Wilcoxon or Student 2-sample t test was applied to estimate statistically significant differences between groups (a=.05).Results. In the partially edentulous model, distance trueness mean & PLUSMN;standard deviation values ranged from -46.7 & PLUSMN;15.4 gm (TRIOS 3) to 392.1 & PLUSMN;314.3 gm (Medit) in models without additional artificial landmarks. When additional artificial landmarks were applied, trueness of distance mean & PLUSMN;standard deviation values ranged between -35 & PLUSMN;13 gm (TRIOS 4) and 117.7 & PLUSMN;232.3 gm (CARESTREAM). Trueness mean & PLUSMN;standard deviation values of angulation varied from -0.0 & PLUSMN;0.5 degrees (CARESTREAM) to 0.2 & PLUSMN;0.0 degrees (PRIMESCAN) without additional artificial landmarks and from 0.0 & PLUSMN;0.2 degrees (TRIOS 3) to 0.4 & PLUSMN;0.5 degrees (CARESTREAM) with additional artificial landmarks. Vertical shift trueness measurements varied from -108 & PLUSMN;47.1 gm (TRIOS 4) to 107.2 & PLUSMN;103.5 gm (Medit) without additional artificial landmarks and from -15.0 & PLUSMN;45.0 gm (CARESTREAM) to -86.9 & PLUSMN;42.1 gm (TRIOS 4) with additional artificial landmarks. The additional artificial landmark technique improved the trueness of all measured parameters for the 5 tested intraoral scanners. No statistically significant differences were found among models with or without additional artificial landmarks, except for Medit in all parameters and PRIMESCAN in angle measurements (P<.05). The best precision for distance was found with TRIOS 3 and with PRIMESCAN for angulation and vertical shift. Larger deviations were observed in the completely edentulous situation. The effect of additional artificial landmarks was limited when the accuracy parameters of digital scans were considered.Conclusions. Scans with and without additional artificial landmarks of partially edentulous conditions scanned by any of the intraoral scanners tested did not influence precision and trueness, except for Medit i500 in the distance and vertical shift parameters and CARESTREAM3600 in vertical shift. Precision and trueness of digital scans of completely edentulous areas were affected, except for Medit i500 for distance, PRIMESCAN and TRIOS 4 for angle, and all systems except TRIOS 4 for vertical shift precision. (J Prosthet Dent 2023;130:111-8)
引用
收藏
页码:111 / 118
页数:8
相关论文
共 50 条
  • [1] Accuracy of intraoral scanning in completely and partially edentulous maxillary and mandibular jaws: an in vitro analysis
    Schimmel, Martin
    Akino, Norio
    Srinivasan, Murali
    Wittneben, Julia-Gabriela
    Yilmaz, Burak
    Abou-Ayash, Samir
    [J]. CLINICAL ORAL INVESTIGATIONS, 2021, 25 (04) : 1839 - 1847
  • [2] Accuracy of intraoral scanning in completely and partially edentulous maxillary and mandibular jaws: an in vitro analysis
    Martin Schimmel
    Norio Akino
    Murali Srinivasan
    Julia-Gabriela Wittneben
    Burak Yilmaz
    Samir Abou-Ayash
    [J]. Clinical Oral Investigations, 2021, 25 : 1839 - 1847
  • [3] Accuracy of intraoral scans of edentulous jaws with different generations of intraoral scanners compared to laboratory scans
    Kontis, Panagiotis
    Gueth, Jan-Frederik
    Schubert, Oliver
    Keul, Christine
    [J]. JOURNAL OF ADVANCED PROSTHODONTICS, 2021, 13 (05): : 316 - 326
  • [4] Repeatability of Intraoral Scanners for Complete Arch Scan of Partially Edentulous Dentitions: An In Vitro Study
    Lee, Jae-Hyun
    Yun, Je-Hyeon
    Han, Jung-Suk
    Yeo, In-Sung Luke
    Yoon, Hyung-In
    [J]. JOURNAL OF CLINICAL MEDICINE, 2019, 8 (08)
  • [5] Exploring the impact of the extent of the partially edentulous area on the accuracy of two intraoral scanners
    Alfaraj, Amal
    Khanlar, Leila Nasiry
    Lin, Wei-Shao
    Zandinejad, Amirali
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2024, 131 (01): : 163.e1 - 163.e8
  • [6] Accuracy of Five Intraoral Scanners and Two Laboratory Scanners for a Complete Arch: A Comparative In Vitro Study
    Kang, Byung-hyun
    Son, Keunbada
    Lee, Kyu-bok
    [J]. APPLIED SCIENCES-BASEL, 2020, 10 (01):
  • [7] Accuracy of Digital Impressions Obtained Using Six Intraoral Scanners in Partially Edentulous Dentitions and the Effect of Scanning Sequence
    Diker, Burcu
    Tak, Onjen
    [J]. INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2021, 34 (01) : 101 - 108
  • [8] Evaluation of the accuracy of seven intraoral scanners for the full dentate and partially edentulous complete-arch mandibular casts: An in vitro comparison
    Wang, Xin
    Zhang, Fang
    Ma, Dan
    Ye, Xiaolan
    Zheng, Xiaojuan
    Ren, Ruifang
    Ren, Nan
    Bai, Shizhu
    [J]. HELIYON, 2024, 10 (10)
  • [9] Effect of Different Intraoral Scanners on the Accuracy of Bite Registration in Edentulous Maxillary and Mandibular Arches
    Rutkunas, Vygandas
    Jegelevicius, Darius
    Gedrimiene, Agne
    Auskalnis, Liudas
    Eyuboglu, Tan Firat
    Ozcan, Mutlu
    Husain, Nadin Al-Haj
    Akulauskas, Mykolas
    Pletkus, Justinas
    [J]. JOURNAL OF DENTISTRY, 2024, 146
  • [10] Effect of preparation type on the accuracy of different intraoral scanners: An in vitro study at different levels of accuracy evaluation
    Abduo, Jaafar
    Laskey, David
    [J]. JOURNAL OF ESTHETIC AND RESTORATIVE DENTISTRY, 2022, 34 (08) : 1221 - 1229