Effect of preparation type on the accuracy of different intraoral scanners: An in vitro study at different levels of accuracy evaluation

被引:3
|
作者
Abduo, Jaafar [1 ]
Laskey, David [1 ]
机构
[1] Univ Melbourne, Melbourne Dent Sch, 720 Swanston St, Melbourne, Vic 3010, Australia
关键词
crown; inlay; margin; onlay; precision; trueness; PRECISION; SYSTEMS; INLAY; FIT;
D O I
10.1111/jerd.12949
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective Evaluation of the effect of preparation type (inlay, onlay, and crown) on the accuracy of different intraoral scanning (IOS) systems at the preparation and arch segment levels. Materials and Methods Three molars were prepared for inlay, onlay, and crown. Each preparation was scanned 10 times by CEREC Omnicam, Trios 3 (TS), and Medit i500 scanners. Each image was trimmed twice. The first trimming produced a preparation image (PI), and the second trimming extracted a segment image (SI) that involved the preparation with the adjacent teeth. Trueness and precision were calculated at the PI and SI levels. Results At the PI level, all IOS systems had similar trueness pattern for all preparations, where the inlay had the best trueness followed by the crown and onlay. At the SI level, the different preparations showed similar trueness. The precision did not show a clear pattern of superiority for any preparation. The TS was significantly more precise than other IOS systems at the PI and SI levels, for every preparation. The proximal areas suffered from the greatest errors, regardless of preparation type. Conclusions The preparation type influenced PI trueness, and the IOS system affected PI and SI precisions. Clinical Significance The smaller and less complex preparations have greater IOS accuracy than larger and more complex preparations. As the proximal areas are more affected regardless of the preparation, a more accessible proximal area for scanning is desirable.
引用
收藏
页码:1221 / 1229
页数:9
相关论文
共 50 条
  • [1] Effect of different preparation designs of minimally invasive occlusal onlays on the accuracy of different intraoral scanners: An in vitro study
    Ashraf, Khadija
    Ebeid, Kamal
    Salah, Tarek
    [J]. JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2023,
  • [2] Evaluation of the effect of different core substrates on the accuracy of intraoral scanners
    Khoshkhahesh, Maryam
    Enteghad, Shabnam
    Aghasadeghi, Kiana
    Farzin, Mitra
    Taghva, Masumeh
    Mosadad, Seyed Ali
    [J]. CLINICAL AND EXPERIMENTAL DENTAL RESEARCH, 2024, 10 (03):
  • [3] Influence of Preparation Type and Tooth Geometry on the Accuracy of Different Intraoral Scanners
    Ashraf, Yasmine
    Sabet, Ahmed
    Hamdy, Amina
    Ebeid, Kamal
    [J]. JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2020, 29 (09): : 800 - 804
  • [4] Accuracy of Four Different Intraoral Scanners According to Different Preparation Geometries
    Schmidt, Alexander
    Benedickt, Christopher R.
    Schlenz, Maximiliane A.
    Rehmann, Peter
    Woestmann, Bernd
    [J]. INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2021, 34 (06) : 756 - 762
  • [5] Effect of Different Preparation Depths for an Inlay-Retained Fixed Partial Denture on the Accuracy of Different Intraoral Scanners: An In Vitro Study
    Khaled, Mohamed
    Sabet, Ahmed
    Ebeid, Kamal
    Salah, Tarek
    [J]. JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2022, 31 (07): : 601 - 605
  • [6] Accuracy evaluation of two different intraoral scanners in implant prosthodontics. A comparative in vitro study
    Verniani, G.
    Casucci, A.
    Nosrati, N.
    D'Arienzo, L. F.
    Val, M.
    Cagidiaco, E. Ferrari
    [J]. JOURNAL OF OSSEOINTEGRATION, 2024, 16 (01) : 61 - 64
  • [7] Accuracy of Scanned Stock Abutments Using Different Intraoral Scanners: An In Vitro Study
    Kim, Jong-Eun
    Hong, Young-Sun
    Kang, You-Jung
    Kim, Jee-Hwan
    Shim, June-Sung
    [J]. JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2019, 28 (07): : 797 - 803
  • [8] Effect of different arch widths on the accuracy of three intraoral scanners
    Kaewbuasa, Narin
    Ongthiemsak, Chakree
    [J]. JOURNAL OF ADVANCED PROSTHODONTICS, 2021, 13 (04): : 205 - 215
  • [9] The effect of different tooth preparation finishing procedures and immediate dentin sealing on the scanning accuracy of different intraoral scanners
    Revilla-Leon, Marta
    Cascos-Sanchez, Rocio
    Barmak, Abdul B.
    Kois, John C.
    Gomez-Polo, Miguel
    [J]. JOURNAL OF DENTISTRY, 2023, 130
  • [10] Effect of different span lengths with different total occlusal convergences on the accuracy of intraoral scanners
    Yehia, Ashraf
    Abo El Fadl, Ahmad
    El Sergany, Omar
    Ebeid, Kamal
    [J]. JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2024, 33 (03): : 252 - 258