Effect of different preparation designs of minimally invasive occlusal onlays on the accuracy of different intraoral scanners: An in vitro study

被引:0
|
作者
Ashraf, Khadija [1 ,2 ]
Ebeid, Kamal [2 ]
Salah, Tarek [2 ,3 ]
机构
[1] Egyptian Russian Univ, Fac Dent, Dept Restorat Dent, Cairo, Egypt
[2] Ain Shams Univ, Fac Dent, Dept Fixed Prosthodont, Org African Unity St, Cairo 11737, Egypt
[3] Misr Int Univ, Fac Dent, Dept Fixed Prosthodont, Cairo, Egypt
关键词
CAD-CAM; digital dentistry; intraoral scanners; minimally invasive occlusal onlay; preparation design; DIGITAL SCANNERS; PRECISION; TRUENESS;
D O I
10.1111/jopr.13812
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: The aim of this in vitro study was to assess and compare three different preparation designs of minimally invasive occlusal onlays on the trueness and precision of three different intraoral scanners under two different scanning conditions.Materials and Methods: Three maxillary premolars were prepared in three different designs and divided accordingly into three groups, Group 1: Anatomical (n = 60), Group 2: Flat (n = 60), and Group 3: Ferrule (n = 60). The samples were then further divided into subgroups according to scanners as subgroup A: Medit i500 (n = 20), subgroup B: 3Shape TRIOS 4 (n = 20), and subgroup C: Cerec Primescan (n = 20). Last, the samples were further divided according to scanning conditions: Division i: As prepared (n = 10) and Division ii: Sprayed - scan spray (n = 10). An industrial 3D scanner was used to obtain the reference STL files. Accuracy was assessed in terms of trueness and precision and recorded in terms of root mean square in micrometers. Numerical data were explored for normality using Shapiro-Wilk test and were analyzed using 3-way ANOVA followed by Tukey's post hoc test.Results: Regarding trueness, 3-way ANOVA showed that all tested variables had a significant effect on trueness. Significant interactions were found between the different variables (p < 0.001). For preparation design the highest value was found in ferrule preparation (27.88 +/- 7.11), followed by flat preparation (22.99 +/- 7.56), while the lowest value was found in anatomical preparation (18.83 +/- 5.71) (p < 0.001). For scanner type, the highest value was found in Primescan (25.36 +/- 10.66), followed by TRIOS 4 (22.75 +/- 5.98), while the lowest value was found in Medit i500 (21.59 +/- 5.03) (p < 0.001). As for the scanning condition, sprayed samples (26.54 +/- 8.24) had a significantly higher value than non-sprayed samples (19.93 +/- 5.53) (p < 0.001). Regarding precision, both preparation design and scanner type had a significant effect on precision. Scanning conditions had no significant effect. There was a significant interaction between the three tested variables (p = 0.012).Conclusions: Anatomical preparation of minimally invasive occlusal onlays produced the most accurate scans. Within the tested preparation designs, Medit i500 and 3Shape TRIOS 4 have better trueness than Cerec Primescan. Cerec Primescan is more precise than 3Shape TRIOS 4 and Medit i500 Scan spray application causes a higher deviation in the trueness of the tested intraoral scanners while it does not affect their precision.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Effect of preparation type on the accuracy of different intraoral scanners: An in vitro study at different levels of accuracy evaluation
    Abduo, Jaafar
    Laskey, David
    [J]. JOURNAL OF ESTHETIC AND RESTORATIVE DENTISTRY, 2022, 34 (08) : 1221 - 1229
  • [2] Effect of different span lengths with different total occlusal convergences on the accuracy of intraoral scanners
    Yehia, Ashraf
    Abo El Fadl, Ahmad
    El Sergany, Omar
    Ebeid, Kamal
    [J]. JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2024, 33 (03): : 252 - 258
  • [3] Effect of Different Preparation Depths for an Inlay-Retained Fixed Partial Denture on the Accuracy of Different Intraoral Scanners: An In Vitro Study
    Khaled, Mohamed
    Sabet, Ahmed
    Ebeid, Kamal
    Salah, Tarek
    [J]. JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2022, 31 (07): : 601 - 605
  • [4] Accuracy of Four Different Intraoral Scanners According to Different Preparation Geometries
    Schmidt, Alexander
    Benedickt, Christopher R.
    Schlenz, Maximiliane A.
    Rehmann, Peter
    Woestmann, Bernd
    [J]. INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2021, 34 (06) : 756 - 762
  • [5] Accuracy of Scanned Stock Abutments Using Different Intraoral Scanners: An In Vitro Study
    Kim, Jong-Eun
    Hong, Young-Sun
    Kang, You-Jung
    Kim, Jee-Hwan
    Shim, June-Sung
    [J]. JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2019, 28 (07): : 797 - 803
  • [6] Influence of Preparation Type and Tooth Geometry on the Accuracy of Different Intraoral Scanners
    Ashraf, Yasmine
    Sabet, Ahmed
    Hamdy, Amina
    Ebeid, Kamal
    [J]. JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2020, 29 (09): : 800 - 804
  • [7] Evaluation of the effect of different core substrates on the accuracy of intraoral scanners
    Khoshkhahesh, Maryam
    Enteghad, Shabnam
    Aghasadeghi, Kiana
    Farzin, Mitra
    Taghva, Masumeh
    Mosadad, Seyed Ali
    [J]. CLINICAL AND EXPERIMENTAL DENTAL RESEARCH, 2024, 10 (03):
  • [8] Effect of different arch widths on the accuracy of three intraoral scanners
    Kaewbuasa, Narin
    Ongthiemsak, Chakree
    [J]. JOURNAL OF ADVANCED PROSTHODONTICS, 2021, 13 (04): : 205 - 215
  • [9] The effect of different tooth preparation finishing procedures and immediate dentin sealing on the scanning accuracy of different intraoral scanners
    Revilla-Leon, Marta
    Cascos-Sanchez, Rocio
    Barmak, Abdul B.
    Kois, John C.
    Gomez-Polo, Miguel
    [J]. JOURNAL OF DENTISTRY, 2023, 130
  • [10] Trueness and Precision of Eight Intraoral Scanners with Different Finishing Line Designs: A Comparative In Vitro Study
    Falih, Mina Yahia
    Majeed, Manhal A.
    [J]. EUROPEAN JOURNAL OF DENTISTRY, 2023, 17 (04) : 1056 - 1064