Accuracy of Scanned Stock Abutments Using Different Intraoral Scanners: An In Vitro Study

被引:15
|
作者
Kim, Jong-Eun [1 ]
Hong, Young-Sun [1 ]
Kang, You-Jung [1 ]
Kim, Jee-Hwan [1 ]
Shim, June-Sung [1 ]
机构
[1] Yonsei Univ, Dept Prosthodont, Coll Dent, 50-1 Yonsei Ro, Seoul 03722, South Korea
关键词
Intraoral scanning; precision; stock abutments; trueness; DIGITAL IMPRESSIONS; EMERGENCE PROFILE; IMPLANTS;
D O I
10.1111/jopr.13095
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose To determine the accuracy of a digital manufacturing method for dental implant restorations on stock abutments using intraoral scanners and prefabricated stock-abutment libraries. Materials and Methods Two dental implants with internal hexagonal connections were placed in the mandibular second premolar and second molar areas of a partially edentulous dentoform model; stock abutments with a diameter of 5 mm, abutment height of 5.5 mm, and gingival cuff height of 2 mm were connected. The study model was scanned 10 times using a reference tabletop scanner and 5 types of intraoral scanners (IOSs). The data collected by 5 types of IOSs were divided into 3 groups, based on the type and matching of stock abutment library data: no library, optical library, and contact library groups. A total of 160 data files were analyzed, including reference data. The resulting data were used to evaluate trueness and precision. Results Trueness and precision values in the group in which library data of the stock abutment were not used were 42.0 to 76.3 mu m and 30.5 to 99.7 mu m; corresponding values when the library data using an optical scanner were matched were 51.2 to 73.4 mu m and 26.3 to 62.8 mu m, and those when contact scanner library data were used were 30.1 to 62.4 mu m and 15.5 to 55.9 mu m. Thus, the accuracy of the contact library group was significantly higher than the accuracies of the no library (p < 0.001) and optical library groups (p < 0.001). Conclusion The application of prefabricated library data of stock abutments using a contact scanner improved the accuracy of scan data. Scan accuracy of the stock abutments differed significantly based on the type of scanner.
引用
收藏
页码:797 / 803
页数:7
相关论文
共 50 条
  • [1] Effect of preparation type on the accuracy of different intraoral scanners: An in vitro study at different levels of accuracy evaluation
    Abduo, Jaafar
    Laskey, David
    [J]. JOURNAL OF ESTHETIC AND RESTORATIVE DENTISTRY, 2022, 34 (08) : 1221 - 1229
  • [2] Original Evaluating the accuracy of three intraoral scanners using models containing different numbers of crown-prepared abutments
    Zhang, Ting
    Wei, Ting
    Zhao, Yawen
    Jiang, Mengyang
    Yin, Xiaojie
    Sun, Huiqiang
    [J]. JOURNAL OF DENTAL SCIENCES, 2022, 17 (01) : 204 - 210
  • [3] Accuracy evaluation of two different intraoral scanners in implant prosthodontics. A comparative in vitro study
    Verniani, G.
    Casucci, A.
    Nosrati, N.
    D'Arienzo, L. F.
    Val, M.
    Cagidiaco, E. Ferrari
    [J]. JOURNAL OF OSSEOINTEGRATION, 2024, 16 (01) : 61 - 64
  • [4] Accuracy of four intraoral scanners in oral implantology: a comparative in vitro study
    Mario Imburgia
    Silvia Logozzo
    Uli Hauschild
    Giovanni Veronesi
    Carlo Mangano
    Francesco Guido Mangano
    [J]. BMC Oral Health, 17
  • [5] Accuracy of four intraoral scanners in oral implantology: a comparative in vitro study
    Imburgia, Mario
    Logozzo, Silvia
    Hauschild, Uli
    Veronesi, Giovanni
    Mangano, Carlo
    Mangano, Francesco Guido
    [J]. BMC ORAL HEALTH, 2017, 17
  • [6] Complete-Arch Accuracy of Four Intraoral Scanners: An In Vitro Study
    Celeghin, Giordano
    Franceschetti, Giulio
    Mobilio, Nicola
    Fasiol, Alberto
    Catapano, Santo
    Corsalini, Massimo
    Grande, Francesco
    [J]. HEALTHCARE, 2021, 9 (03)
  • [7] Influence of Liquid on the Tooth Surface on the Accuracy of Intraoral Scanners: An In Vitro Study
    Chen, Yuming
    Zhai, Zhihao
    Li, Hefei
    Yamada, Shuhei
    Matsuoka, Takashi
    Ono, Shinji
    Nakano, Tamaki
    [J]. JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2022, 31 (01): : 59 - 64
  • [8] Effect of different preparation designs of minimally invasive occlusal onlays on the accuracy of different intraoral scanners: An in vitro study
    Ashraf, Khadija
    Ebeid, Kamal
    Salah, Tarek
    [J]. JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2023,
  • [9] Comparative Analysis of Four Different Intraoral Scanners: An In Vitro Study
    Ciocan, Lucian Toma
    Vasilescu, Vlad Gabriel
    Rauta, Sabina-Ana
    Pantea, Mihaela
    Pituru, Silviu-Mirel
    Imre, Marina
    [J]. DIAGNOSTICS, 2024, 14 (13)
  • [10] Accuracy of Five Intraoral Scanners and Two Laboratory Scanners for a Complete Arch: A Comparative In Vitro Study
    Kang, Byung-hyun
    Son, Keunbada
    Lee, Kyu-bok
    [J]. APPLIED SCIENCES-BASEL, 2020, 10 (01):