Accuracy evaluation of two different intraoral scanners in implant prosthodontics. A comparative in vitro study

被引:0
|
作者
Verniani, G. [1 ]
Casucci, A. [1 ]
Nosrati, N. [1 ]
D'Arienzo, L. F. [1 ]
Val, M. [2 ]
Cagidiaco, E. Ferrari [1 ]
机构
[1] Univ Siena, Dept Prosthodont, Siena, Italy
[2] Univ Siena, Dept Orofacial Pain, Siena, Italy
关键词
Accuracy; digital impression; implant dentistry; digital dentistry; intraoral scanner; DIGITAL IMPRESSIONS; EDENTULOUS JAW; PRECISION; TECHNOLOGY;
D O I
10.23805/JO.2024.619
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Aim To test differences in term of accuracy among two Intraoral Scanners used in implant fixed prosthodontics. Materials and methods A reference stone model was prepared, representing a partially edentulous maxilla on area #23 and from #14 to #16, with three implant analogues and polyether-etherketone (PEEK) scanbody screwed on to represent the situation of a single crown on implant (SB) and a implant -supported partial prosthesis (2SB). The model was digitized with a laboratory scanner (Aadva lab scanner, GC, Tokyo, Japan) used as a reference, and with two intraoral scanners (Trios 3; 3Shape A/S; I700, Medit). Ten scans were performed using the two different intraoral scanner. Scanning and processing time as well as the number of images were reordered for each scanner. All datasets were loaded into reverse -engineering software (Geomagic Control X 2018), where digital impressions were superimposed on the reference model to evaluate trueness in the full arch, in the SB area (#23) and in the2SB areas(#14 and #16).Therefore, all the scans of the same group were superimposed onto the cast that recorded the best result of trueness whose trueness corresponded to the actual reference value for precision. Mann -Whitney U -test test was performed to analyze differences between the groups (P<0,05) (SPSS software Version 26,IBM). Results Statistically significative differences where found between Medit i700 and TRIOS 3 regarding trueness and precision in the full arch , with Trios 3 showing better results than Medit I700. Trios 3 performed statistically better also in the 2SB area regarding precision. No statistically significative differences were found regarding trueness and precision in the other areas. Conclusions Trios 3 performed statistically significative better than Medit I700 in acquiring scanbody position when the full arch model was analyzed. Both the tested Intraoral scanners reordered good values in line with the previous literature.
引用
收藏
页码:61 / 64
页数:4
相关论文
共 50 条
  • [1] Intraoral scanners in implant prosthodontics. A narrative review
    Rutkunas, Vygandas
    Auskanis, Liudas
    Pletkus, Justinas
    [J]. JOURNAL OF DENTISTRY, 2024, 148
  • [2] Accuracy of Five Intraoral Scanners and Two Laboratory Scanners for a Complete Arch: A Comparative In Vitro Study
    Kang, Byung-hyun
    Son, Keunbada
    Lee, Kyu-bok
    [J]. APPLIED SCIENCES-BASEL, 2020, 10 (01):
  • [3] Effect of preparation type on the accuracy of different intraoral scanners: An in vitro study at different levels of accuracy evaluation
    Abduo, Jaafar
    Laskey, David
    [J]. JOURNAL OF ESTHETIC AND RESTORATIVE DENTISTRY, 2022, 34 (08) : 1221 - 1229
  • [4] Comparative study of different impression techniques in fixed prosthodontics.
    Aponte, A
    [J]. JOURNAL OF DENTAL RESEARCH, 1996, 75 (05) : 1319 - 1319
  • [5] Comparative Analysis of Four Different Intraoral Scanners: An In Vitro Study
    Ciocan, Lucian Toma
    Vasilescu, Vlad Gabriel
    Rauta, Sabina-Ana
    Pantea, Mihaela
    Pituru, Silviu-Mirel
    Imre, Marina
    [J]. DIAGNOSTICS, 2024, 14 (13)
  • [6] Accuracy of four intraoral scanners in oral implantology: a comparative in vitro study
    Imburgia, Mario
    Logozzo, Silvia
    Hauschild, Uli
    Veronesi, Giovanni
    Mangano, Carlo
    Mangano, Francesco Guido
    [J]. BMC ORAL HEALTH, 2017, 17
  • [7] Accuracy of four intraoral scanners in oral implantology: a comparative in vitro study
    Mario Imburgia
    Silvia Logozzo
    Uli Hauschild
    Giovanni Veronesi
    Carlo Mangano
    Francesco Guido Mangano
    [J]. BMC Oral Health, 17
  • [8] Trueness and Precision of Two Intraoral Scanners: A Comparative In Vitro Study
    Rotar, Raul Nicolae
    Jivanescu, Anca
    Ille, Codruta
    Podariu, Angela Codruta
    Jumanca, Daniela Elisabeta
    Matichescu, Ana-Maria
    Balean, Octavia
    Rusu, Laura Cristina
    [J]. SCANNING, 2019, 2019
  • [9] In vitro Evaluation of Accuracy of Single Dies Captured by Two Intraoral Digital Scanners
    Burde, Alexandru Victor
    Gasparik, Cristina
    Moldovan, Marioara
    Baciu, Sorana
    Cosma, Cosmin
    [J]. MATERIALE PLASTICE, 2018, 55 (02) : 176 - 178
  • [10] Investigation of the Accuracy of Four Intraoral Scanners in Mandibular Full-Arch Digital Implant Impression: A Comparative In Vitro Study
    Di Fiore, Adolfo
    Graiff, Lorenzo
    Savio, Gianpaolo
    Granata, Stefano
    Basilicata, Michele
    Bollero, Patrizio
    Meneghello, Roberto
    [J]. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2022, 19 (08)