Trueness and Precision of Two Intraoral Scanners: A Comparative In Vitro Study

被引:8
|
作者
Rotar, Raul Nicolae [1 ]
Jivanescu, Anca [1 ]
Ille, Codruta [1 ]
Podariu, Angela Codruta [2 ]
Jumanca, Daniela Elisabeta [2 ]
Matichescu, Ana-Maria [2 ]
Balean, Octavia [2 ]
Rusu, Laura Cristina [3 ]
机构
[1] Univ Med & Farm Timisoara, Dept Prosthodont, B Dul Revolutiei 1989,9, Timisoara 300580, Romania
[2] Univ Med & Farm Timisoara, Dept Prevent Dent Community & Oral Hlth, Splaiul Tudor Vladimirescu 14 A, Timisoara 300174, Romania
[3] Univ Med & Farm Timisoara, Dept Oral Pathol, Splaiul Tudor Vladimirescu 14 A, Timisoara 300174, Romania
关键词
DIGITAL IMPRESSION TECHNIQUE; LITHIUM DISILICATE CROWNS; MARGINAL FIT; CONVENTIONAL IMPRESSIONS; ARCH IMPRESSIONS; ACCURACY; TIME; RELIABILITY; EFFICIENCY; 3D;
D O I
10.1155/2019/1289570
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The aim of this study was to evaluate the accuracy of two intraoral scanners used in the dental office. A molar fixed in a typodont was prepared for a ceramic onlay. The preparation was scanned using a high-resolution scanner (reference scanner) and saved as stereolithography (STL) format. The prepared resin molar was scanned again using the intraoral scanners, and all the scans were saved as well in STL format. All STL files were compared using metrology software (Geomagic Control X). Overlapping the meshes allowed the assessment of the scans in terms of trueness and precision. Based on the results of this study, the differences of trueness and precision between the intraoral scanners were minimal.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Trueness and Precision of Four Intraoral Scanners in Oral Implantology: A Comparative in Vitro Study
    Mangano, Francesco G.
    Veronesi, Giovanni
    Hauschild, Uli
    Mijiritsky, Eitan
    Mangano, Carlo
    [J]. PLOS ONE, 2016, 11 (09):
  • [2] Trueness and precision of 5 intraoral scanners in the impressions of single and multiple implants: a comparative in vitro study
    Francesco Guido Mangano
    Uli Hauschild
    Giovanni Veronesi
    Mario Imburgia
    Carlo Mangano
    Oleg Admakin
    [J]. BMC Oral Health, 19
  • [3] Trueness and precision of 5 intraoral scanners in the impressions of single and multiple implants: a comparative in vitro study
    Mangano, Francesco Guido
    Hauschild, Uli
    Veronesi, Giovanni
    Imburgia, Mario
    Mangano, Carlo
    Admakin, Oleg
    [J]. BMC ORAL HEALTH, 2019, 19 (1)
  • [4] Trueness and Precision of Eight Intraoral Scanners with Different Finishing Line Designs: A Comparative In Vitro Study
    Falih, Mina Yahia
    Majeed, Manhal A.
    [J]. EUROPEAN JOURNAL OF DENTISTRY, 2023, 17 (04) : 1056 - 1064
  • [5] Evaluation of trueness and precision of two intraoral scanners and a conventional impression: an in vivo clinical study
    Jorquera, Gilbert J.
    Sampaio, Camila S.
    Bozzalla, Antonia
    Hirata, Ronaldo
    Sanchez, Juan Pablo
    [J]. QUINTESSENCE INTERNATIONAL, 2021, 52 (10): : 904 - 910
  • [6] The effect of software updates on the trueness and precision of intraoral scanners
    Vag, Janos
    Renne, Walter
    Revell, Griffin
    Ludlow, Mark
    Mennito, Anthony
    Teich, Sorin T.
    Gutmacher, Zvi
    [J]. QUINTESSENCE INTERNATIONAL, 2021, 52 (07): : 636 - 644
  • [7] Effect of posterior span length on the trueness and precision of 3 intraoral digital scanners: A comparative 3-dimensional in vitro study
    Fattouh, Mohamed
    Kenawi, Laila Mohamed Mohamed
    Fattouh, Hesham
    [J]. IMAGING SCIENCE IN DENTISTRY, 2021, 51 (04) : 399 - 406
  • [8] Trueness and precision of 5 intraoral scanners for scanning edentulous and dentate complete-arch mandibular casts: A comparative in vitro study
    Braian, Michael
    Wennerberg, Ann
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2019, 122 (02): : 129 - 136
  • [9] Trueness of 12 intraoral scanners in the full-arch implant impression: a comparative in vitro study
    Mangano, Francesco Guido
    Admakin, Oleg
    Bonacina, Matteo
    Lerner, Henriette
    Rutkunas, Vygandas
    Mangano, Carlo
    [J]. BMC ORAL HEALTH, 2020, 20 (01)
  • [10] Trueness of 12 intraoral scanners in the full-arch implant impression: a comparative in vitro study
    Francesco Guido Mangano
    Oleg Admakin
    Matteo Bonacina
    Henriette Lerner
    Vygandas Rutkunas
    Carlo Mangano
    [J]. BMC Oral Health, 20