Trueness and Precision of Four Intraoral Scanners in Oral Implantology: A Comparative in Vitro Study

被引:131
|
作者
Mangano, Francesco G. [1 ,2 ]
Veronesi, Giovanni [3 ]
Hauschild, Uli
Mijiritsky, Eitan [4 ]
Mangano, Carlo [2 ]
机构
[1] Insubria Univ, Sch Dent, Dept Surg & Morphol Sci, Varese, Italy
[2] IRCCS S Raffaele Hosp, Acad Unit Digital Dent, Milan, Italy
[3] Insubria Univ, Sch Med, Dept Clin & Expt Med, Varese, Italy
[4] Tel Aviv Univ, Maurice & Gabriela Goldschleger Sch Dent Med, Dept Oral Rehabil, Ramat Tel Aviv, Israel
来源
PLOS ONE | 2016年 / 11卷 / 09期
关键词
RANDOMIZED CLINICAL-TRIAL; DIGITAL IMPRESSIONS; CONVENTIONAL IMPRESSIONS; ARCH IMPRESSIONS; MARGINAL FIT; CROWNS; ACCURACY; EFFICIENCY; TIME; RESTORATIONS;
D O I
10.1371/journal.pone.0163107
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Purpose The aim of this study was to compare the trueness and precision of four intraoral scanners used in oral implantology. Methods Two stone models were prepared, representing a partially and a totally edentulous maxilla, with three and six implant analogues, respectively, and polyether-ether-ketone (PEEK) cylinders screwed on. The models were digitized with an industrial scanner (IScan D104I (R)) used as a reference, and with four intraoral scanners (Trios (R); CS 3500 (R); Zfx Intrascan (R); Planscan (R)). Five scans were taken for each model, using each different intraoral scanner. All datasets were loaded into reverse-engineering software (Geomagics 2012 (R)), where intraoral scans were superimposed on the reference model, to evaluate general trueness, and superimposed on each other within groups, to evaluate general precision. General trueness and precision of any scanner were compared by model type, through an ANOVA model including scanner, model and their interaction. Finally, the distance and angles between simulated implants were measured in each group, and compared to those of the reference model, to evaluate local trueness. Results In the partially edentulous maxilla, CS 3500 (R) had the best general trueness (47.8 mu m) and precision (40.8 mu m), followed by Trios (R) (trueness 71.2 mu m, precision 51.0 mu m), Zfx Intrascan (R) (trueness 117.0 mu m, precision 126.2 mu m), and Planscan (R) (trueness 233.4 mu m, precision 219.8 mu m). With regard to general trueness, Trios (R) was significantly better than Planscan (R), CS 3500 (R) was significantly better than Zfx Intrascan (R) and Planscan (R), and Zfx Intrascan (R) was significantly better than Planscan (R); with regard to general precision, Trios (R) was significantly better than Zfx Intrascan (R) and Planscan (R), CS 3500 (R) was significantly better than Zfx Intrascan (R) and Planscan (R), and Zfx Intrascan (R) was significantly better than Planscan (R). In the totally edentulous maxilla, CS 3500 (R) had the best performance in terms of general trueness (63.2 mu m) and precision (55.2 mu m), followed by Trios (R) (trueness 71.6 mu m, precision 67.0 mu m), Zfx Intrascan (R) (trueness 103.0 mu m, precision 112.4 mu m), and Planscan (R) (trueness 253.4 mu m, precision 204.2 mu m). With regard to general trueness, Trios (R) was significantly better than Planscan (R), CS 3500 (R) was significantly better than Zfx Intrascan (R) and Planscan (R), and Zfx Intrascan (R) was significantly better than Planscan (R); with regard to general precision, Trios (R) was significantly better than Zfx Intrascan (R) and Planscan (R), CS 3500 (R) was significantly better than Zfx Intrascan (R) and Planscan (R), and Zfx Intrascan (R) was significantly better than Planscan (R). Local trueness values confirmed these results. Conclusions Although no differences in trueness and precision were found between partially and totally edentulous models, statistically significant differences were found between the different scanners. Further studies are required to confirm these results.
引用
收藏
页数:18
相关论文
共 50 条
  • [1] Accuracy of four intraoral scanners in oral implantology: a comparative in vitro study
    Imburgia, Mario
    Logozzo, Silvia
    Hauschild, Uli
    Veronesi, Giovanni
    Mangano, Carlo
    Mangano, Francesco Guido
    [J]. BMC ORAL HEALTH, 2017, 17
  • [2] Accuracy of four intraoral scanners in oral implantology: a comparative in vitro study
    Mario Imburgia
    Silvia Logozzo
    Uli Hauschild
    Giovanni Veronesi
    Carlo Mangano
    Francesco Guido Mangano
    [J]. BMC Oral Health, 17
  • [3] Trueness and Precision of Two Intraoral Scanners: A Comparative In Vitro Study
    Rotar, Raul Nicolae
    Jivanescu, Anca
    Ille, Codruta
    Podariu, Angela Codruta
    Jumanca, Daniela Elisabeta
    Matichescu, Ana-Maria
    Balean, Octavia
    Rusu, Laura Cristina
    [J]. SCANNING, 2019, 2019
  • [4] Trueness and precision of 5 intraoral scanners in the impressions of single and multiple implants: a comparative in vitro study
    Francesco Guido Mangano
    Uli Hauschild
    Giovanni Veronesi
    Mario Imburgia
    Carlo Mangano
    Oleg Admakin
    [J]. BMC Oral Health, 19
  • [5] Trueness and precision of 5 intraoral scanners in the impressions of single and multiple implants: a comparative in vitro study
    Mangano, Francesco Guido
    Hauschild, Uli
    Veronesi, Giovanni
    Imburgia, Mario
    Mangano, Carlo
    Admakin, Oleg
    [J]. BMC ORAL HEALTH, 2019, 19 (1)
  • [6] Trueness and Precision of Eight Intraoral Scanners with Different Finishing Line Designs: A Comparative In Vitro Study
    Falih, Mina Yahia
    Majeed, Manhal A.
    [J]. EUROPEAN JOURNAL OF DENTISTRY, 2023, 17 (04) : 1056 - 1064
  • [7] In Vitro Trueness and Precision of Intraoral Scanners in a Four-Implant Complete-Arch Model
    Spagopoulos, Dimitrios
    Kaisarlis, George
    Spagopoulou, Foteini
    Halazonetis, Demetrios J. J.
    Gueth, Jan-Frederik
    Papazoglou, Efstratios
    [J]. DENTISTRY JOURNAL, 2023, 11 (01)
  • [8] Effect of substrate adjacent to the scan region on the trueness of four intraoral scanners: An in vitro study
    Elter, Bahar
    Tak, Onjen
    [J]. JOURNAL OF DENTISTRY, 2023, 138
  • [9] Comparative Analysis of Four Different Intraoral Scanners: An In Vitro Study
    Ciocan, Lucian Toma
    Vasilescu, Vlad Gabriel
    Rauta, Sabina-Ana
    Pantea, Mihaela
    Pituru, Silviu-Mirel
    Imre, Marina
    [J]. DIAGNOSTICS, 2024, 14 (13)
  • [10] The effect of software updates on the trueness and precision of intraoral scanners
    Vag, Janos
    Renne, Walter
    Revell, Griffin
    Ludlow, Mark
    Mennito, Anthony
    Teich, Sorin T.
    Gutmacher, Zvi
    [J]. QUINTESSENCE INTERNATIONAL, 2021, 52 (07): : 636 - 644