Effect of substrate adjacent to the scan region on the trueness of four intraoral scanners: An in vitro study

被引:1
|
作者
Elter, Bahar [1 ]
Tak, Onjen [2 ]
机构
[1] Baskent Univ, Istanbul Hosp, Istanbul, Turkiye
[2] Istinye Univ, Fac Dent, Dept Prosthodont, Istanbul, Turkiye
关键词
Dental materials; Digital impression; Intraoral scanner; Proximal contact area; Trueness; DIGITAL IMPRESSION; ACCURACY; PRECISION; SYSTEMS; TRANSLUCENCY; TEETH;
D O I
10.1016/j.jdent.2023.104729
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: The purpose of this in vitro study was to evaluate the trueness of four commercially available intraoral scanners (IOSs) on scanning different substrates that existed in the adjacent proximal contact area.Methods: Four IOSs (TRIOS 4, TRIOS 3, Primescan, Omnicam) were used for scanning the intact enamel surface of a molar tooth, and six restorative materials (zirconia, lithium disilicate glass-ceramic, composite resin, hybrid ceramic, feldspathic ceramic, metal) that were located at the adjacent proximal contact area of the same tooth. Reference scans were obtained using an extraoral scanner (inEos X5). A 3-dimensional analyzing software (Geomagic Control X) was used to compare the reference and tested scans. The two-way analysis of variance (ANOVA) followed by Bonferroni correction was performed for statistical analyses (alpha=0.05).Results: TRIOS 3 and TRIOS 4 showed higher trueness than Primescan, and Primescan showed higher trueness than Omnicam (p<0.001), while there were no differences between TRIOS 3 and TRIOS 4. Metal showed significantly higher Root Mean Square values (0.273 +/- 0.24 mm) than other substrates. No difference was found between the scanners' zirconia, lithium disilicate glass-ceramic, composite, and feldspathic ceramic scans (p > 0.05). For the metal, TRIOS 3 and TRIOS 4 showed higher trueness than Primescan and Omnicam, while Omnicam showed lower trueness among all scanners. For the hybrid ceramic, TRIOS 3 showed higher trueness than Omnicam (p<0.001). For the enamel, TRIOS 3 showed higher trueness than Primescan and Omnicam (p<0.001).Conclusions: The trueness of IOSs can be affected by the substrates that exist in the proximal contact area. Amongst all, the metal substrate affected most the trueness of the IOSs.Clinical Significance: The clinician should decide on the impression system, taking into account that the IOS and the surfaces to be scanned affect the trueness of the digital data. The deviation of the digital impression would be high in the presence of a metal restoration on the adjacent proximal surface.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Trueness and Precision of Four Intraoral Scanners in Oral Implantology: A Comparative in Vitro Study
    Mangano, Francesco G.
    Veronesi, Giovanni
    Hauschild, Uli
    Mijiritsky, Eitan
    Mangano, Carlo
    [J]. PLOS ONE, 2016, 11 (09):
  • [2] Trueness and Precision of Two Intraoral Scanners: A Comparative In Vitro Study
    Rotar, Raul Nicolae
    Jivanescu, Anca
    Ille, Codruta
    Podariu, Angela Codruta
    Jumanca, Daniela Elisabeta
    Matichescu, Ana-Maria
    Balean, Octavia
    Rusu, Laura Cristina
    [J]. SCANNING, 2019, 2019
  • [3] Effect of splinting scan bodies on trueness of complete-arch implant impression using different intraoral scanners: an in vitro study
    Retana, Luciano
    Nejat, Amir H.
    Pozzi, Alessandro
    [J]. INTERNATIONAL JOURNAL OF COMPUTERIZED DENTISTRY, 2023, 26 (01) : 19 - 28
  • [4] In Vitro Trueness and Precision of Intraoral Scanners in a Four-Implant Complete-Arch Model
    Spagopoulos, Dimitrios
    Kaisarlis, George
    Spagopoulou, Foteini
    Halazonetis, Demetrios J. J.
    Gueth, Jan-Frederik
    Papazoglou, Efstratios
    [J]. DENTISTRY JOURNAL, 2023, 11 (01)
  • [5] The effect of software updates on the trueness and precision of intraoral scanners
    Vag, Janos
    Renne, Walter
    Revell, Griffin
    Ludlow, Mark
    Mennito, Anthony
    Teich, Sorin T.
    Gutmacher, Zvi
    [J]. QUINTESSENCE INTERNATIONAL, 2021, 52 (07): : 636 - 644
  • [6] Trueness of ten intraoral scanners in determining the positions of simulated implant scan bodies
    Kim, Ryan Jin Young
    Benic, Goran, I
    Park, Ji-Man
    [J]. SCIENTIFIC REPORTS, 2021, 11 (01)
  • [7] Influence of crown shade, translucency, and scan powder application on the trueness of intraoral scanners
    Hlaing, Nan Hsu Myat Mon
    Lee, Hyeonjong
    Jeong, Yuwon
    Park, Ji-Man
    Lee, Sang J.
    Lee, Jae-Hyun
    [J]. JOURNAL OF DENTISTRY, 2024, 144
  • [8] Trueness of ten intraoral scanners in determining the positions of simulated implant scan bodies
    Ryan Jin Young Kim
    Goran I. Benic
    Ji-Man Park
    [J]. Scientific Reports, 11
  • [9] Comparative Analysis of Four Different Intraoral Scanners: An In Vitro Study
    Ciocan, Lucian Toma
    Vasilescu, Vlad Gabriel
    Rauta, Sabina-Ana
    Pantea, Mihaela
    Pituru, Silviu-Mirel
    Imre, Marina
    [J]. DIAGNOSTICS, 2024, 14 (13)
  • [10] Trueness and precision of 5 intraoral scanners in the impressions of single and multiple implants: a comparative in vitro study
    Francesco Guido Mangano
    Uli Hauschild
    Giovanni Veronesi
    Mario Imburgia
    Carlo Mangano
    Oleg Admakin
    [J]. BMC Oral Health, 19