Effect of additional reference objects on accuracy of five intraoral scanners in partially and completely edentulous jaws: An in vitro study

被引:11
|
作者
Rutkunas, Vygandas [1 ,8 ]
Gedrimiene, Agne [1 ]
Husain, Nadin Al-Haj [2 ,3 ]
Pletkus, Justinas [4 ]
Barauskis, Dainius [5 ]
Jegelevicius, Darius [6 ,7 ]
Ozcan, Mutlu [2 ]
机构
[1] Vilnius Univ, Inst Odontol, Fac Med, Dept Prosthodont, Vilnius, Lithuania
[2] Univ Zurich, Ctr Dent Med, Div Dent Biomat, Clin Reconstruct Dent, Zurich, Switzerland
[3] Univ Bern, Sch Dent Med, Dept Reconstruct Dent & Gerodontol, Bern, Switzerland
[4] Vilnius Univ, Inst Odontol, Med Fac, Vilnius, Lithuania
[5] Kaunas Univ Technol, Biomed Engn Inst, Kaunas, Lithuania
[6] Kaunas Univ Technol, Biomed Engn Inst, Kaunas, Lithuania
[7] Kaunas Univ Technol, Fac Elect & Elect Engn, Kaunas, Lithuania
[8] Vilnius Univ, Inst Odontol, Fac Med, Dept Prosthodont, Zalgirio str 115, LT-08217 Vilnius, Lithuania
来源
JOURNAL OF PROSTHETIC DENTISTRY | 2023年 / 130卷 / 01期
关键词
IMPRESSIONS; PRECISION; MAXILLA;
D O I
10.1016/j.prosdent.2021.09.032
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. The effect of additional reference objects on the accuracy of different intraoral scanners for partially and completely edentulous patients has not been investigated sufficiently.Purpose. The purpose of this in vitro study was to evaluate the effect of an additional reference object in the form of additional artificial landmarks on the trueness and precision of different intraoral scanners in partially and completely edentulous areas.Material and methods. Partially and completely edentulous models with 2 and 4 implants (BLT, RC, Institut Straumann AG), respectively, were used in the study. For the digital scan, scan bodies (CARES Mono Scanbody) were attached, and reference data obtained by using industrial scanners. Ten digital scans of the same model were made with each intraoral scanner: PRIMESCAN, TRIOS 3, TRIOS 4, Carestream 3600, and Medit. Then, additional artificial landmarks were attached, and 10 more intraoral scans were made with each device. Computer-aided design files of the scan bodies were aligned to obtain 3-dimensional surfaces with reference and test scanners. Trueness and precision of distance, angulations, and vertical shift between scan bodies were estimated. The Mann-Whitney Wilcoxon or Student 2-sample t test was applied to estimate statistically significant differences between groups (a=.05).Results. In the partially edentulous model, distance trueness mean & PLUSMN;standard deviation values ranged from -46.7 & PLUSMN;15.4 gm (TRIOS 3) to 392.1 & PLUSMN;314.3 gm (Medit) in models without additional artificial landmarks. When additional artificial landmarks were applied, trueness of distance mean & PLUSMN;standard deviation values ranged between -35 & PLUSMN;13 gm (TRIOS 4) and 117.7 & PLUSMN;232.3 gm (CARESTREAM). Trueness mean & PLUSMN;standard deviation values of angulation varied from -0.0 & PLUSMN;0.5 degrees (CARESTREAM) to 0.2 & PLUSMN;0.0 degrees (PRIMESCAN) without additional artificial landmarks and from 0.0 & PLUSMN;0.2 degrees (TRIOS 3) to 0.4 & PLUSMN;0.5 degrees (CARESTREAM) with additional artificial landmarks. Vertical shift trueness measurements varied from -108 & PLUSMN;47.1 gm (TRIOS 4) to 107.2 & PLUSMN;103.5 gm (Medit) without additional artificial landmarks and from -15.0 & PLUSMN;45.0 gm (CARESTREAM) to -86.9 & PLUSMN;42.1 gm (TRIOS 4) with additional artificial landmarks. The additional artificial landmark technique improved the trueness of all measured parameters for the 5 tested intraoral scanners. No statistically significant differences were found among models with or without additional artificial landmarks, except for Medit in all parameters and PRIMESCAN in angle measurements (P<.05). The best precision for distance was found with TRIOS 3 and with PRIMESCAN for angulation and vertical shift. Larger deviations were observed in the completely edentulous situation. The effect of additional artificial landmarks was limited when the accuracy parameters of digital scans were considered.Conclusions. Scans with and without additional artificial landmarks of partially edentulous conditions scanned by any of the intraoral scanners tested did not influence precision and trueness, except for Medit i500 in the distance and vertical shift parameters and CARESTREAM3600 in vertical shift. Precision and trueness of digital scans of completely edentulous areas were affected, except for Medit i500 for distance, PRIMESCAN and TRIOS 4 for angle, and all systems except TRIOS 4 for vertical shift precision. (J Prosthet Dent 2023;130:111-8)
引用
收藏
页码:111 / 118
页数:8
相关论文
共 50 条
  • [41] Correction to: Accuracy of full‑arch digitalization for partially edentulous jaws — a laboratory study on basis of coordinate‑based data analysis
    Panagiotis Kontis
    Jan‑Frederik Güth
    Christine Keul
    [J]. Clinical Oral Investigations, 2022, 26 : 3663 - 3663
  • [42] Effect of substrate adjacent to the scan region on the trueness of four intraoral scanners: An in vitro study
    Elter, Bahar
    Tak, Onjen
    [J]. JOURNAL OF DENTISTRY, 2023, 138
  • [43] Accuracy of models of partially edentulous arches obtained by three-dimensional printing: An in vitro study
    Curinga, Miria Rafaelli Souza
    de Sousa, Lucas Cavalcante
    Pereira, Ana Larisse Carneiro
    Segundo, Henrique Vieira de Melo
    Dantas, Lucas Medeiros Cunha Maciel
    Carreiro, Adriana da Fonte Porto
    [J]. JOURNAL OF INDIAN PROSTHODONTIC SOCIETY, 2023, 23 (04): : 356 - 362
  • [44] Accuracy of capturing nasal, orbital, and auricular defects with extra- and intraoral optical scanners and smartphone: An in vitro study
    Unkovskiy, Alexey
    Spintzyk, Sebastian
    Beuer, Florian
    Huettig, Fabian
    Roehler, Ariadne
    Kraemer-Fernandez, Pablo
    [J]. JOURNAL OF DENTISTRY, 2022, 117
  • [45] Accuracy of full-arch digitalization for partially edentulous jaws - a laboratory study on basis of coordinate-based data analysis
    Panagiotis, Kontis
    Jan-Frederik, Guth
    Christine, Keul
    [J]. CLINICAL ORAL INVESTIGATIONS, 2022, 26 (04) : 3651 - 3662
  • [46] Accuracy of full-arch digitalization for partially edentulous jaws — a laboratory study on basis of coordinate-based data analysis
    Panagiotis Kontis
    Jan-Frederik Güth
    Christine Keul
    [J]. Clinical Oral Investigations, 2022, 26 : 3651 - 3662
  • [47] The influence of crown coverage on the accuracy of static guided implant surgery in partially edentulous models: An in vitro study
    Wang, Zhen-yu
    Chao, Jia-rui
    Zheng, Jia-wen
    You, Meng
    Liu, Yang
    Shen, Jie-fei
    [J]. JOURNAL OF DENTISTRY, 2021, 115
  • [48] The Influence of Hard- and Software Improvement of Intraoral Scanners on the Implant Transfer Accuracy from 2012 to 2021: An In Vitro Study
    Schmidt, Alexander
    Schlenz, Maximiliane Amelie
    Liu, Haoyu
    Kaempe, Holger Sebastian
    Woestmann, Bernd
    [J]. APPLIED SCIENCES-BASEL, 2021, 11 (15):
  • [49] Is There a Significant Difference in Accuracy of Four Intraoral Scanners for Short-Span Fixed Dental Prosthesis? A Comparative In Vitro Study
    Jivanescu, Anca
    Bara, Adrian
    Faur, Andrei-Bogdan
    Rotar, Raul Nicolae
    [J]. APPLIED SCIENCES-BASEL, 2021, 11 (18):
  • [50] Investigation of the Accuracy of Four Intraoral Scanners in Mandibular Full-Arch Digital Implant Impression: A Comparative In Vitro Study
    Di Fiore, Adolfo
    Graiff, Lorenzo
    Savio, Gianpaolo
    Granata, Stefano
    Basilicata, Michele
    Bollero, Patrizio
    Meneghello, Roberto
    [J]. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2022, 19 (08)