Is There a Significant Difference in Accuracy of Four Intraoral Scanners for Short-Span Fixed Dental Prosthesis? A Comparative In Vitro Study

被引:7
|
作者
Jivanescu, Anca [1 ]
Bara, Adrian [2 ]
Faur, Andrei-Bogdan [2 ]
Rotar, Raul Nicolae [1 ]
机构
[1] Univ Med & Farm Timisoara, TADERP Res Ctr, Dept Prosthodont, B Dul Revolutiei 1989,9, Timisoara 300580, Romania
[2] Univ Med & Farm Timisoara, Dept Prosthodont, B Dul Revolutiei 1989,9, Timisoara 300580, Romania
来源
APPLIED SCIENCES-BASEL | 2021年 / 11卷 / 18期
关键词
intraoral scanner; trueness; precision; accuracy; fixed dental prostheses; CONVENTIONAL IMPRESSIONS; PRECISION; TIME;
D O I
10.3390/app11188280
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Is the accuracy of the older generation of IOSs an impediment for obtaining a quality intraoral digital impression? The aim of this study was to evaluate the differences in accuracy between four intraoral scanners (two of the latest IOSs and two older IOSs) in the scenario of a short span fixed partial denture, and to determine if these differences have a major impact on the quality of the final digital impression. Four intraoral scanners: Cerec PrimeScan, Medit i700, Cerec Omnicam and Planmeca PlanScan and one laboratory scanner were used in this study. The scanned data were processed with the help of Geomagic Control X, a metrology software. For the statistical data analysis, the level of significance was set as 0.05 (alpha = 0.05). The Medit i700 group displayed the best level of trueness with the median value of 23.25 mu m, PrimeScan group with a median of 25.55 mu m, Omnicam group with a median of 32.3 mu m and the PlanScan group which displayed the lowest level of trueness with a median value of 75.8 mu m. From the precision data analysis, it was concluded that the PrimeScan group showed the best results, followed by Medit i700, Omnicam and the PlanScan group which showed the lowest precision. Even if there are some significant differences in accuracy between old and new IOSs, in the in vitro scenario of short span dental prostheses, the accuracy values were within the clinically acceptable range and may present important clinical implications.
引用
收藏
页数:9
相关论文
共 25 条
  • [1] Accuracy of four intraoral scanners in oral implantology: a comparative in vitro study
    Mario Imburgia
    Silvia Logozzo
    Uli Hauschild
    Giovanni Veronesi
    Carlo Mangano
    Francesco Guido Mangano
    [J]. BMC Oral Health, 17
  • [2] Accuracy of four intraoral scanners in oral implantology: a comparative in vitro study
    Imburgia, Mario
    Logozzo, Silvia
    Hauschild, Uli
    Veronesi, Giovanni
    Mangano, Carlo
    Mangano, Francesco Guido
    [J]. BMC ORAL HEALTH, 2017, 17
  • [3] Comparative Analysis of Four Different Intraoral Scanners: An In Vitro Study
    Ciocan, Lucian Toma
    Vasilescu, Vlad Gabriel
    Rauta, Sabina-Ana
    Pantea, Mihaela
    Pituru, Silviu-Mirel
    Imre, Marina
    [J]. DIAGNOSTICS, 2024, 14 (13)
  • [4] Complete-Arch Accuracy of Four Intraoral Scanners: An In Vitro Study
    Celeghin, Giordano
    Franceschetti, Giulio
    Mobilio, Nicola
    Fasiol, Alberto
    Catapano, Santo
    Corsalini, Massimo
    Grande, Francesco
    [J]. HEALTHCARE, 2021, 9 (03)
  • [5] Comparative Accuracy of Intraoral and Extraoral Digital Workflows for Short Span Implant Supported Fixed Partial Denture Fabrication: An In Vitro Study
    Mansoor, Manawar Ahmad
    Sayed, Mohammed E.
    Abdul, Hina Naim
    Zaidan, Meshal Saleh
    Hakami, Thamer Mohammad
    Dighriri, Mohammed Abdullah
    Alqahtani, Saeed M.
    Alfaifi, Mohammed A.
    Altoman, Majed S.
    Jokhadar, Hossam F.
    AlResayes, Saad Saleh
    AlWadei, Mohammed H.
    Jundus, Asayil Ibrahim
    Komosany, Abeer Mohammed
    Al-Najjar, Hind Ziyad
    [J]. MEDICAL SCIENCE MONITOR, 2024, 30
  • [6] Accuracy of Five Intraoral Scanners and Two Laboratory Scanners for a Complete Arch: A Comparative In Vitro Study
    Kang, Byung-hyun
    Son, Keunbada
    Lee, Kyu-bok
    [J]. APPLIED SCIENCES-BASEL, 2020, 10 (01):
  • [7] Trueness and Precision of Four Intraoral Scanners in Oral Implantology: A Comparative in Vitro Study
    Mangano, Francesco G.
    Veronesi, Giovanni
    Hauschild, Uli
    Mijiritsky, Eitan
    Mangano, Carlo
    [J]. PLOS ONE, 2016, 11 (09):
  • [8] Investigation of the Accuracy of Four Intraoral Scanners in Mandibular Full-Arch Digital Implant Impression: A Comparative In Vitro Study
    Di Fiore, Adolfo
    Graiff, Lorenzo
    Savio, Gianpaolo
    Granata, Stefano
    Basilicata, Michele
    Bollero, Patrizio
    Meneghello, Roberto
    [J]. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2022, 19 (08)
  • [9] Comparative study of the accuracy of an implant intraoral scanner and that of a conventional intraoral scanner for-arch fixed dental
    Sallorenzo, Alessandro
    Gomez-Polo, Miguel
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2022, 128 (05): : 1009 - 1016
  • [10] Accuracy evaluation of two different intraoral scanners in implant prosthodontics. A comparative in vitro study
    Verniani, G.
    Casucci, A.
    Nosrati, N.
    D'Arienzo, L. F.
    Val, M.
    Cagidiaco, E. Ferrari