Effect of additional reference objects on accuracy of five intraoral scanners in partially and completely edentulous jaws: An in vitro study

被引:11
|
作者
Rutkunas, Vygandas [1 ,8 ]
Gedrimiene, Agne [1 ]
Husain, Nadin Al-Haj [2 ,3 ]
Pletkus, Justinas [4 ]
Barauskis, Dainius [5 ]
Jegelevicius, Darius [6 ,7 ]
Ozcan, Mutlu [2 ]
机构
[1] Vilnius Univ, Inst Odontol, Fac Med, Dept Prosthodont, Vilnius, Lithuania
[2] Univ Zurich, Ctr Dent Med, Div Dent Biomat, Clin Reconstruct Dent, Zurich, Switzerland
[3] Univ Bern, Sch Dent Med, Dept Reconstruct Dent & Gerodontol, Bern, Switzerland
[4] Vilnius Univ, Inst Odontol, Med Fac, Vilnius, Lithuania
[5] Kaunas Univ Technol, Biomed Engn Inst, Kaunas, Lithuania
[6] Kaunas Univ Technol, Biomed Engn Inst, Kaunas, Lithuania
[7] Kaunas Univ Technol, Fac Elect & Elect Engn, Kaunas, Lithuania
[8] Vilnius Univ, Inst Odontol, Fac Med, Dept Prosthodont, Zalgirio str 115, LT-08217 Vilnius, Lithuania
来源
JOURNAL OF PROSTHETIC DENTISTRY | 2023年 / 130卷 / 01期
关键词
IMPRESSIONS; PRECISION; MAXILLA;
D O I
10.1016/j.prosdent.2021.09.032
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. The effect of additional reference objects on the accuracy of different intraoral scanners for partially and completely edentulous patients has not been investigated sufficiently.Purpose. The purpose of this in vitro study was to evaluate the effect of an additional reference object in the form of additional artificial landmarks on the trueness and precision of different intraoral scanners in partially and completely edentulous areas.Material and methods. Partially and completely edentulous models with 2 and 4 implants (BLT, RC, Institut Straumann AG), respectively, were used in the study. For the digital scan, scan bodies (CARES Mono Scanbody) were attached, and reference data obtained by using industrial scanners. Ten digital scans of the same model were made with each intraoral scanner: PRIMESCAN, TRIOS 3, TRIOS 4, Carestream 3600, and Medit. Then, additional artificial landmarks were attached, and 10 more intraoral scans were made with each device. Computer-aided design files of the scan bodies were aligned to obtain 3-dimensional surfaces with reference and test scanners. Trueness and precision of distance, angulations, and vertical shift between scan bodies were estimated. The Mann-Whitney Wilcoxon or Student 2-sample t test was applied to estimate statistically significant differences between groups (a=.05).Results. In the partially edentulous model, distance trueness mean & PLUSMN;standard deviation values ranged from -46.7 & PLUSMN;15.4 gm (TRIOS 3) to 392.1 & PLUSMN;314.3 gm (Medit) in models without additional artificial landmarks. When additional artificial landmarks were applied, trueness of distance mean & PLUSMN;standard deviation values ranged between -35 & PLUSMN;13 gm (TRIOS 4) and 117.7 & PLUSMN;232.3 gm (CARESTREAM). Trueness mean & PLUSMN;standard deviation values of angulation varied from -0.0 & PLUSMN;0.5 degrees (CARESTREAM) to 0.2 & PLUSMN;0.0 degrees (PRIMESCAN) without additional artificial landmarks and from 0.0 & PLUSMN;0.2 degrees (TRIOS 3) to 0.4 & PLUSMN;0.5 degrees (CARESTREAM) with additional artificial landmarks. Vertical shift trueness measurements varied from -108 & PLUSMN;47.1 gm (TRIOS 4) to 107.2 & PLUSMN;103.5 gm (Medit) without additional artificial landmarks and from -15.0 & PLUSMN;45.0 gm (CARESTREAM) to -86.9 & PLUSMN;42.1 gm (TRIOS 4) with additional artificial landmarks. The additional artificial landmark technique improved the trueness of all measured parameters for the 5 tested intraoral scanners. No statistically significant differences were found among models with or without additional artificial landmarks, except for Medit in all parameters and PRIMESCAN in angle measurements (P<.05). The best precision for distance was found with TRIOS 3 and with PRIMESCAN for angulation and vertical shift. Larger deviations were observed in the completely edentulous situation. The effect of additional artificial landmarks was limited when the accuracy parameters of digital scans were considered.Conclusions. Scans with and without additional artificial landmarks of partially edentulous conditions scanned by any of the intraoral scanners tested did not influence precision and trueness, except for Medit i500 in the distance and vertical shift parameters and CARESTREAM3600 in vertical shift. Precision and trueness of digital scans of completely edentulous areas were affected, except for Medit i500 for distance, PRIMESCAN and TRIOS 4 for angle, and all systems except TRIOS 4 for vertical shift precision. (J Prosthet Dent 2023;130:111-8)
引用
收藏
页码:111 / 118
页数:8
相关论文
共 50 条
  • [31] Palatal vault configuration and its influence on intraoral scan time and accuracy in completely edentulous arches: a prospective clinical study
    Elawady, Dina Mohamed Ahmed
    Ibrahim, Wafaa Ibrahim
    Ghanem, Radwa Gamal
    Osman, Reham Bassuni
    [J]. JOURNAL OF ADVANCED PROSTHODONTICS, 2024, 16 (04): : 201 - 211
  • [32] Accuracy of implant abutment level digital impressions using stereophotogrammetry in edentulous jaws: an in vitro pilot study
    Zhou, Yuan
    You, Lang
    Fan, Zhen
    [J]. BMC ORAL HEALTH, 2024, 24 (01):
  • [33] The impact of mandibular partial edentulous distal extension on virtual occlusal record accuracy when using two different intraoral scanners: An in vitro analysis
    Tian, Jiehua
    Jung, Ronald Ernst
    Han, Yuqi
    Mei, Yupeng
    Di, Ping
    [J]. JOURNAL OF DENTISTRY, 2024, 150
  • [34] RESEARCH AND EDUCATION Effect of scan-path length on the scanning accuracy of completely dentate and partially edentulous maxillae
    Waldecker, Moritz
    Rues, Stefan
    Behnisch, Rouven
    Rammelsberg, Peter
    Boemicke, Wolfgang
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2024, 131 (01): : 146 - 154
  • [35] Congruence between Meshes and Library Files of Implant Scanbodies: An In Vitro Study Comparing Five Intraoral Scanners
    Mangano, Francesco
    Lerner, Henriette
    Margiani, Bidzina
    Solop, Ivan
    Latuta, Nadezhda
    Admakin, Oleg
    [J]. JOURNAL OF CLINICAL MEDICINE, 2020, 9 (07) : 1 - 18
  • [36] Effect of Different Preparation Depths for an Inlay-Retained Fixed Partial Denture on the Accuracy of Different Intraoral Scanners: An In Vitro Study
    Khaled, Mohamed
    Sabet, Ahmed
    Ebeid, Kamal
    Salah, Tarek
    [J]. JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2022, 31 (07): : 601 - 605
  • [37] Effect of pulp chamber depth on the accuracy of endocrown scans made with different intraoral scanners versus an industrial scanner: An in vitro study
    Gurpinar, Bahar
    Tak, Onjen
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2022, 127 (03): : 430 - 437
  • [38] Impact of intraoral scanner, scanning strategy, and scanned arch on the scan accuracy of edentulous arches: An in vitro study
    Jamjoom, Faris Z.
    Aldghim, Adhwaa
    Aldibasi, Omar
    Yilmaz, Burak
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2024, 131 (06): : 1218 - 1225
  • [39] Influence of Different Material Substrates on the Accuracy of Three Intraoral Scanners: A Single-Blinded In Vitro Study
    Michelinakis, George
    Apostolakis, Dimitrios
    Tsagarakis, Andreas
    Lampropoulos, Panagiotis
    [J]. INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2022, 35 (01) : 82 - 93
  • [40] Trueness and precision of 5 intraoral scanners for scanning edentulous and dentate complete-arch mandibular casts: A comparative in vitro study
    Braian, Michael
    Wennerberg, Ann
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2019, 122 (02): : 129 - 136