Attenuation images of optical CT using Fricke xylenol orange gel for dose mapping in radiotherapy

被引:0
|
作者
Tavares, P. V. S. [1 ]
Diniz, R. E. [1 ]
Rodrigues Jr, O. [1 ]
Campos, L. L. [1 ]
机构
[1] Energy & Nucl Res Inst, Ionizing Radiat Metrol Ctr, Ave Prof Lineu Prestes,2242, BR-05508000 Sao Paulo, SP, Brazil
基金
巴西圣保罗研究基金会;
关键词
3D dosimetry; Fricke gel; Optical CT; ITERATIVE RECONSTRUCTION ALGORITHM; GELATIN GEL; DISTRIBUTIONS; SCANNER; SIMULATIONS; DOSIMETER;
D O I
10.1016/j.radphyschem.2024.112016
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The Fricke gel dosimeter, a gel-based solution containing ferrous ions, can be used for three-dimensional dosimetry by adding xylenol orange to the solution. This changes the optical properties, affecting radiation absorption. These gel dosimeters are recommended for clinical use, and 3D dosimetry uses optical computed tomography (OCT) to analyze reconstructed images. Advancements in radiotherapy focus on accurate irradiation while reducing doses to nearby tissues. This study uses modified FXO gel for 3D dosimetry, utilizing non-toxic, easy-to-handle reagents and optical CT Vista 16 equipment. The experiment aims to characterize the system's practicality and evaluate the impact of lead filters on attenuation values. The study also examines trends in attenuation values for different thicknesses of lead shields, enhancing our understanding of the relationship between attenuation and dose using optical CT. To prevent artifacts, a modified FXO gel was created by introducing a variation of XO in the preparation. The ideal concentration of XO is 0.01 mM to prevent distortions within the dose range of 1 Gy-10 Gy. A calibration system using FXO gel can be developed by comparing the maximum irradiation dose with the attenuation observed in the gel. The modified gel showed a sensitivity of 5.5.10-3 +/- 2.6.10-4 cm- 1/Gy and a starting dose of 4.2 Gy. Two samples were tested using different configurations of lead filters, with the central holes showing dose peaks of 4.72 Gy, 4.57 Gy, and 4.32 Gy, respectively. The results suggest the feasibility of producing modified FXO gels for examination in optical CT systems and their potential application in radiotherapy systems. Future research is being conducted in clinical irradiation to facilitate comparison with system designs.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Characterisation of a Ferrous Agarose Xylenol (FAX) gel for radiotherapy dose measurement
    Leong, Lee Hon
    Kandaiya, S.
    Seng, Ng Bong
    AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2007, 30 (02) : 135 - 140
  • [32] Optical CT reconstruction of 3D dose distributions using the ferrous-benzoic-xylenol (FBX) gel dosimeter
    Kelly, RG
    Jordan, KJ
    Battista, JJ
    MEDICAL PHYSICS, 1998, 25 (09) : 1741 - 1750
  • [33] Effect of saccharide additives on response of ferrous-agarose-xylenol orange radiotherapy gel dosimeters
    Healy, BJ
    Zahmatkesh, MH
    Nitschke, KN
    Baldock, C
    MEDICAL PHYSICS, 2003, 30 (09) : 2282 - 2291
  • [34] A systematic review of the precision and accuracy of dose measurements in photon radiotherapy using polymer and Fricke MRI gel dosimetry
    MacDougall, N
    Pitchford, WG
    Smith, MA
    PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (20): : R107 - R121
  • [35] Three-dimensional radiation dose measurements with ferrous benzoic acid xylenol orange in gelatin gel and optical absorption tomography
    Bero, MA
    Gilboy, WB
    Glover, PM
    Keddie, JL
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 422 (1-3): : 617 - 620
  • [36] How Xylenol Orange and Ferrous Ammonium Sulphate Influence the Dosimetric Properties of PVA-GTA Fricke Gel Dosimeters: A Spectrophotometric Study
    Scotti, Martina
    Arosio, Paolo
    Brambilla, Elisa
    Gallo, Salvatore
    Lenardi, Cristina
    Locarno, Silvia
    Orsini, Francesco
    Pignoli, Emanuele
    Pedicone, Luca
    Veronese, Ivan
    GELS, 2022, 8 (04)
  • [37] Dose mapping of an irradiation chamber of a gamma cell unit using Fricke gel dosimeters and Monte Carlo simulation
    Edalatkhah, Elham
    Badiei, Shahryar
    APPLIED RADIATION AND ISOTOPES, 2025, 217
  • [38] Comment on 'A systematic review of the precision and accuracy of dose measurements in photon radiotherapy using polymer and Fricke MRI gel dosimetry'
    De Deene, Y
    De Wagter, C
    Baldock, C
    PHYSICS IN MEDICINE AND BIOLOGY, 2003, 48 (03): : L15 - L18
  • [39] Dosimetric parameters for small field sizes using Fricke xylenol gel, thermoluminescent and film dosimeters, and an ionization chamber
    Calcina, Carmen S. Guzman
    de Oliveira, Lucas N.
    de Almeida, Carlos E.
    de Almeida, Adelaide
    PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (05): : 1431 - 1439
  • [40] Reply to 'Comment on 'A systematic review of the precision and accuracy of dose measurements in photon radiotherapy using polymer and Fricke MRI gel dosimetry"
    MacDougall, ND
    Pitchford, WG
    Smith, MA
    PHYSICS IN MEDICINE AND BIOLOGY, 2003, 48 (04): : L19 - L22