Comment on 'A systematic review of the precision and accuracy of dose measurements in photon radiotherapy using polymer and Fricke MRI gel dosimetry'

被引:0
|
作者
De Deene, Y [1 ]
De Wagter, C
Baldock, C
机构
[1] Ghent Univ Hosp, Dept Radiotherapy, B-9000 Ghent, Belgium
[2] Queensland Univ Technol, Ctr Med Hlth & Environm Phys, Brisbane, Qld, Australia
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2003年 / 48卷 / 03期
关键词
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
引用
收藏
页码:L15 / L18
页数:4
相关论文
共 15 条
  • [1] Reply to 'Comment on 'A systematic review of the precision and accuracy of dose measurements in photon radiotherapy using polymer and Fricke MRI gel dosimetry"
    MacDougall, ND
    Pitchford, WG
    Smith, MA
    PHYSICS IN MEDICINE AND BIOLOGY, 2003, 48 (04): : L19 - L22
  • [2] A systematic review of the precision and accuracy of dose measurements in photon radiotherapy using polymer and Fricke MRI gel dosimetry
    MacDougall, N
    Pitchford, WG
    Smith, MA
    PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (20): : R107 - R121
  • [3] Polymer gel dosimetry for synchrotron stereotactic radiotherapy and iodine dose-enhancement measurements
    Boudou, C.
    Tropres, I.
    Rousseau, J.
    Lamalle, L.
    Adam, J. F.
    Esteve, F.
    Elleaume, H.
    PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (16): : 4881 - 4892
  • [4] Dose resolution in radiotherapy polymer gel dosimetry:: effect of echo spacing in MRI pulse sequence
    Baldock, C
    Lepage, M
    Bäck, SÅJ
    Murry, PJ
    Jayasekera, PM
    Porter, D
    Kron, T
    PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (02): : 449 - 460
  • [5] Gel dosimetry measurements and Monte Carlo modeling for external radiotherapy photon beams comparison with a treatment planning system dose distribution
    Valente, M.
    Aon, E.
    Brunetto, A.
    Castellano, G.
    Gallivanone, F.
    Gambarini, G.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 580 (01): : 497 - 501
  • [6] Relative output factor measurements of a 5 mm diameter radiosurgical photon beam using polymer gel dosimetry
    Pappas, E
    Petrokokkinos, L
    Angelopoulos, A
    Maris, TG
    Kozicki, M
    Dalezios, I
    Kouloulias, V
    MEDICAL PHYSICS, 2005, 32 (06) : 1513 - 1520
  • [7] Dose resolution in radiotherapy polymer gel dosimetry:: effect of echo spacing in MRI pulse sequence (vol 46, pg 449, 2001)
    Baldock, C
    Lepage, M
    Bäck, SÅJ
    Murry, PJ
    Jayasekera, PM
    Porter, D
    Kron, T
    PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (05): : 1591 - 1591
  • [8] Reduced dose uncertainty in MRI-based polymer gel dosimetry using parallel RF transmission with multiple RF sources
    Sang-Young Kim
    Hyeon-Man Baek
    Jung-Hoon Lee
    Dae-Hyun Kim
    Jin-Young Jung
    Do-Wan Lee
    Jung-Whan Min
    Ji-Yeon Park
    Seu-Ran Lee
    Bo-Young Choe
    Journal of Radioanalytical and Nuclear Chemistry, 2014, 302 : 533 - 541
  • [9] Differential dose volume histograms of Gamma Knife in the presence of inhomogeneities using MRI-polymer gel dosimetry and MC simulation
    Pourfallah, Tayyeb Allahverdi
    Allahverdi, Mahmoud
    Alam, Nader Riahi
    Ay, Mohammad-Reza
    Zahmatkesh, Mohammad-Hasan
    MEDICAL PHYSICS, 2009, 36 (07) : 3002 - 3012
  • [10] Reduced dose uncertainty in MRI-based polymer gel dosimetry using parallel RF transmission with multiple RF sources
    Kim, Sang-Young
    Baek, Hyeon-Man
    Lee, Jung-Hoon
    Kim, Dae-Hyun
    Jung, Jin-Young
    Lee, Do-Wan
    Min, Jung-Whan
    Park, Ji-Yeon
    Lee, Seu-Ran
    Choe, Bo-Young
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2014, 302 (01) : 533 - 541