Reply to 'Comment on 'A systematic review of the precision and accuracy of dose measurements in photon radiotherapy using polymer and Fricke MRI gel dosimetry"

被引:0
|
作者
MacDougall, ND [1 ]
Pitchford, WG
Smith, MA
机构
[1] St Thomas Hosp, Dept Med Phys, London, England
[2] Lincoln Hosp, Dept Med Phys, Lincoln, England
[3] Univ Leeds, Acad Unit Med Phys, Leeds, W Yorkshire, England
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2003年 / 48卷 / 04期
关键词
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
引用
收藏
页码:L19 / L22
页数:4
相关论文
共 15 条
  • [1] Comment on 'A systematic review of the precision and accuracy of dose measurements in photon radiotherapy using polymer and Fricke MRI gel dosimetry'
    De Deene, Y
    De Wagter, C
    Baldock, C
    PHYSICS IN MEDICINE AND BIOLOGY, 2003, 48 (03): : L15 - L18
  • [2] A systematic review of the precision and accuracy of dose measurements in photon radiotherapy using polymer and Fricke MRI gel dosimetry
    MacDougall, N
    Pitchford, WG
    Smith, MA
    PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (20): : R107 - R121
  • [3] Polymer gel dosimetry for synchrotron stereotactic radiotherapy and iodine dose-enhancement measurements
    Boudou, C.
    Tropres, I.
    Rousseau, J.
    Lamalle, L.
    Adam, J. F.
    Esteve, F.
    Elleaume, H.
    PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (16): : 4881 - 4892
  • [4] Dose resolution in radiotherapy polymer gel dosimetry:: effect of echo spacing in MRI pulse sequence
    Baldock, C
    Lepage, M
    Bäck, SÅJ
    Murry, PJ
    Jayasekera, PM
    Porter, D
    Kron, T
    PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (02): : 449 - 460
  • [5] Gel dosimetry measurements and Monte Carlo modeling for external radiotherapy photon beams comparison with a treatment planning system dose distribution
    Valente, M.
    Aon, E.
    Brunetto, A.
    Castellano, G.
    Gallivanone, F.
    Gambarini, G.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 580 (01): : 497 - 501
  • [6] Relative output factor measurements of a 5 mm diameter radiosurgical photon beam using polymer gel dosimetry
    Pappas, E
    Petrokokkinos, L
    Angelopoulos, A
    Maris, TG
    Kozicki, M
    Dalezios, I
    Kouloulias, V
    MEDICAL PHYSICS, 2005, 32 (06) : 1513 - 1520
  • [7] Dose resolution in radiotherapy polymer gel dosimetry:: effect of echo spacing in MRI pulse sequence (vol 46, pg 449, 2001)
    Baldock, C
    Lepage, M
    Bäck, SÅJ
    Murry, PJ
    Jayasekera, PM
    Porter, D
    Kron, T
    PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (05): : 1591 - 1591
  • [8] Reduced dose uncertainty in MRI-based polymer gel dosimetry using parallel RF transmission with multiple RF sources
    Sang-Young Kim
    Hyeon-Man Baek
    Jung-Hoon Lee
    Dae-Hyun Kim
    Jin-Young Jung
    Do-Wan Lee
    Jung-Whan Min
    Ji-Yeon Park
    Seu-Ran Lee
    Bo-Young Choe
    Journal of Radioanalytical and Nuclear Chemistry, 2014, 302 : 533 - 541
  • [9] Differential dose volume histograms of Gamma Knife in the presence of inhomogeneities using MRI-polymer gel dosimetry and MC simulation
    Pourfallah, Tayyeb Allahverdi
    Allahverdi, Mahmoud
    Alam, Nader Riahi
    Ay, Mohammad-Reza
    Zahmatkesh, Mohammad-Hasan
    MEDICAL PHYSICS, 2009, 36 (07) : 3002 - 3012
  • [10] Reduced dose uncertainty in MRI-based polymer gel dosimetry using parallel RF transmission with multiple RF sources
    Kim, Sang-Young
    Baek, Hyeon-Man
    Lee, Jung-Hoon
    Kim, Dae-Hyun
    Jung, Jin-Young
    Lee, Do-Wan
    Min, Jung-Whan
    Park, Ji-Yeon
    Lee, Seu-Ran
    Choe, Bo-Young
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2014, 302 (01) : 533 - 541