Attenuation images of optical CT using Fricke xylenol orange gel for dose mapping in radiotherapy

被引:0
|
作者
Tavares, P. V. S. [1 ]
Diniz, R. E. [1 ]
Rodrigues Jr, O. [1 ]
Campos, L. L. [1 ]
机构
[1] Energy & Nucl Res Inst, Ionizing Radiat Metrol Ctr, Ave Prof Lineu Prestes,2242, BR-05508000 Sao Paulo, SP, Brazil
基金
巴西圣保罗研究基金会;
关键词
3D dosimetry; Fricke gel; Optical CT; ITERATIVE RECONSTRUCTION ALGORITHM; GELATIN GEL; DISTRIBUTIONS; SCANNER; SIMULATIONS; DOSIMETER;
D O I
10.1016/j.radphyschem.2024.112016
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The Fricke gel dosimeter, a gel-based solution containing ferrous ions, can be used for three-dimensional dosimetry by adding xylenol orange to the solution. This changes the optical properties, affecting radiation absorption. These gel dosimeters are recommended for clinical use, and 3D dosimetry uses optical computed tomography (OCT) to analyze reconstructed images. Advancements in radiotherapy focus on accurate irradiation while reducing doses to nearby tissues. This study uses modified FXO gel for 3D dosimetry, utilizing non-toxic, easy-to-handle reagents and optical CT Vista 16 equipment. The experiment aims to characterize the system's practicality and evaluate the impact of lead filters on attenuation values. The study also examines trends in attenuation values for different thicknesses of lead shields, enhancing our understanding of the relationship between attenuation and dose using optical CT. To prevent artifacts, a modified FXO gel was created by introducing a variation of XO in the preparation. The ideal concentration of XO is 0.01 mM to prevent distortions within the dose range of 1 Gy-10 Gy. A calibration system using FXO gel can be developed by comparing the maximum irradiation dose with the attenuation observed in the gel. The modified gel showed a sensitivity of 5.5.10-3 +/- 2.6.10-4 cm- 1/Gy and a starting dose of 4.2 Gy. Two samples were tested using different configurations of lead filters, with the central holes showing dose peaks of 4.72 Gy, 4.57 Gy, and 4.32 Gy, respectively. The results suggest the feasibility of producing modified FXO gels for examination in optical CT systems and their potential application in radiotherapy systems. Future research is being conducted in clinical irradiation to facilitate comparison with system designs.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] A study on Fricke-PVA-xylenol orange hydrogel dosimeter for E-beam radiotherapy
    Cao Fangqi
    Yang Liming
    Chen Jie
    Lin Han
    Fan Jinchen
    Rong Liang
    Luo Wenyun
    Zha Yuanzi
    Wu Guohua
    NUCLEAR SCIENCE AND TECHNIQUES, 2009, 20 (03) : 152 - 156
  • [22] A very low diffusion Fricke gel dosimeter with functionalised xylenol orange-PVA (XOPVA)
    Smith, S. T.
    Boase, N. R. B.
    Masters, K-S
    Hosokawa, K.
    Asena, A.
    Crowe, S. B.
    Kairn, T.
    Trapp, J., V
    PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (20):
  • [23] A study on Fricke-PVA-xylenol orange hydrogel dosimeter for E-beam radiotherapy
    CAO Fangqi1 YANG Liming1 CHEN Jie1 LIN Han1 FAN Jinchen1 RONG Liang1 LUO Wenyun1 ZHA Yuanzi2 WU Guohua2 1Department of Chemical Engineering and Technology
    Nuclear Science and Techniques, 2009, 20 (03) : 152 - 156
  • [24] Measurements of the Fe3+ diffusion coefficient in Fricke Xylenol gel using optical density measurements
    de Oliveira, Lucas Nonato
    Almeida Sampaio, Francisco Glaildo
    Moreira, Marcos Vasques
    de Almeida, Adelaide
    APPLIED RADIATION AND ISOTOPES, 2014, 90 : 241 - 244
  • [25] Energy dependence of Fricke-xylenol orange gel and gel based on Turnbull blue for low-energy photons
    Solc, Jaroslav
    Sochor, Vladimir
    Kozubikova, Petra
    8TH INTERNATIONAL CONFERENCE ON 3D RADIATION DOSIMETRY (IC3DDOSE), 2015, 573
  • [26] Effect of ionizing radiation on the colorimetric properties of PVA-GTA Xylenol Orange Fricke gel dosimeters
    Gallo, Salvatore
    Pasquale, Stefania
    Lenardi, Cristina
    Veronese, Ivan
    Gueli, Anna Maria
    DYES AND PIGMENTS, 2021, 187
  • [27] Evaluation of a novel physically cross-linked fricke-xylenol orange-polyvinyl alcohol radio-chromic gel dosimeter for radiotherapy
    Eyadeh, Molham M.
    Rabaeh, Khalid A.
    Alshomali, Laith S.
    Diamond, Kevin R.
    Oglat, Ammar A.
    RADIATION MEASUREMENTS, 2024, 177
  • [28] Thermoplastic Mask Influence with High Energy Electron Radiotherapy Evaluated by the Fricke Xylenol Gel Chemical Dosimeter
    Moreira, M. V.
    Petchevist, P. C. D.
    de Almeida, A.
    APPLICATION OF ACCELERATORS IN RESEARCH AND INDUSTRY, 2009, 1099 : 472 - +
  • [29] Studies of Fricke-PVA-GTA Xylenol Orange Hydrogels for 3D Measurements in Radiotherapy Dosimetry
    Gallo, Salvatore
    Bettega, Daniela
    Gambarini, Grazia
    Lenardi, Cristina
    Veronese, Ivan
    25TH INTERNATIONAL CONFERENCE ON THE APPLICATION OF ACCELERATORS IN RESEARCH AND INDUSTRY (CAARI 2018), 2019, 2160
  • [30] Characterisation of a Ferrous Agarose Xylenol ( FAX ) gel for radiotherapy dose measurement
    Lee Hon Leong
    S. Kandaiya
    Ng Bong Seng
    Australasian Physics & Engineering Sciences in Medicine, 2007, 30 : 135 - 140