Characterisation of a Ferrous Agarose Xylenol ( FAX ) gel for radiotherapy dose measurement

被引:0
|
作者
Lee Hon Leong
S. Kandaiya
Ng Bong Seng
机构
[1] Pantai Mutiara Hospital,Department of Radiotherapy
[2] Universiti Sains Malaysia,School of Physics
关键词
FAX gel; energy dependence; reproducibility;
D O I
暂无
中图分类号
学科分类号
摘要
The oxidation of ferrous to ferric ions due to ionizing radiation has been used for chemical dosimetry since 1927. The introduction of metal indicator dye xylenol orange (XO) sensitises the measurement of ferric ion yield. A ferrous sulphate- agarose- xylenol orange (FAX) gel was prepared and the gel then exposed to dose ranging from 0.2 to 10 Gy using various high energy photon and electron beams from a linear accelerator. Some general characteristics of FAX such as energy dependence, optical density (OD)-dose relationship, reproducibility and auto-oxidation of ferrous ions were analysed. The radiation yield G of the gel was calculated for gels prepared in oxygen and in air and the values were 46.3±2.1 and 40.9±1.4 Fe3+ per 100 eV for photons respectively. However for stock gel which was kept for 5 days preirradiation the G value decreased to 36.6±1.1. The gel shows linearity in OD-dose relationship, energy independence and reproducibility over the dose range investigated. Auto-oxidation of ferrous ions resulted in optical density changes of less than 1.5% per day.
引用
收藏
页码:135 / 140
页数:5
相关论文
共 50 条
  • [1] Characterisation of a Ferrous Agarose Xylenol (FAX) gel for radiotherapy dose measurement
    Leong, Lee Hon
    Kandaiya, S.
    Seng, Ng Bong
    AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2007, 30 (02) : 135 - 140
  • [2] Effect of saccharide additives on response of ferrous-agarose-xylenol orange radiotherapy gel dosimeters
    Healy, BJ
    Zahmatkesh, MH
    Nitschke, KN
    Baldock, C
    MEDICAL PHYSICS, 2003, 30 (09) : 2282 - 2291
  • [3] IMAGING OF RADIATION-DOSE BY VISIBLE COLOR DEVELOPMENT IN FERROUS-AGAROSE-XYLENOL ORANGE GELS
    APPLEBY, A
    LEGHROUZ, A
    MEDICAL PHYSICS, 1991, 18 (02) : 309 - 312
  • [4] Characterization of ferrous-agarose-xylenol gel dosimeter at 60Co γ-rays beam therapy unit
    Ouiza Moussous
    Radiological Physics and Technology, 2021, 14 : 105 - 112
  • [5] Characterization of ferrous-agarose-xylenol gel dosimeter at 60Co γ-rays beam therapy unit
    Moussous, Ouiza
    RADIOLOGICAL PHYSICS AND TECHNOLOGY, 2021, 14 (01) : 105 - 112
  • [6] Study on characteristic of Fricke xylenol gel dosimeter: application for dose evaluation in radiotherapy
    Choosin, P.
    Tippayamontri, T.
    Ninlaphruk, S.
    Pungkun, V
    INTERNATIONAL NUCLEAR SCIENCE AND TECHNOLOGY CONFERENCE, 2019, 1285
  • [7] Attenuation images of optical CT using Fricke xylenol orange gel for dose mapping in radiotherapy
    Tavares, P. V. S.
    Diniz, R. E.
    Rodrigues Jr, O.
    Campos, L. L.
    RADIATION PHYSICS AND CHEMISTRY, 2024, 224
  • [8] Three-dimensional determination of absorbed dose by spectrophotometric analysis of ferrous-sulphate agarose gel
    Gambarini, G
    Gomarasca, G
    Marchesini, R
    Pecci, A
    Pirola, L
    Tomatis, S
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 422 (1-3): : 643 - 648
  • [9] An apparent threshold dose response in ferrous xylenol-orange gel dosimeters when scanned with a yellow light source
    Babic, Steven
    Battista, Jerry
    Jordan, Kevin
    PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (06): : 1637 - 1650
  • [10] Three-dimensional radiation dose measurements with ferrous benzoic acid xylenol orange in gelatin gel and optical absorption tomography
    Bero, MA
    Gilboy, WB
    Glover, PM
    Keddie, JL
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 422 (1-3): : 617 - 620