Characterisation of a Ferrous Agarose Xylenol ( FAX ) gel for radiotherapy dose measurement

被引:0
|
作者
Lee Hon Leong
S. Kandaiya
Ng Bong Seng
机构
[1] Pantai Mutiara Hospital,Department of Radiotherapy
[2] Universiti Sains Malaysia,School of Physics
来源
Australasian Physics & Engineering Sciences in Medicine | 2007年 / 30卷
关键词
FAX gel; energy dependence; reproducibility;
D O I
暂无
中图分类号
学科分类号
摘要
The oxidation of ferrous to ferric ions due to ionizing radiation has been used for chemical dosimetry since 1927. The introduction of metal indicator dye xylenol orange (XO) sensitises the measurement of ferric ion yield. A ferrous sulphate- agarose- xylenol orange (FAX) gel was prepared and the gel then exposed to dose ranging from 0.2 to 10 Gy using various high energy photon and electron beams from a linear accelerator. Some general characteristics of FAX such as energy dependence, optical density (OD)-dose relationship, reproducibility and auto-oxidation of ferrous ions were analysed. The radiation yield G of the gel was calculated for gels prepared in oxygen and in air and the values were 46.3±2.1 and 40.9±1.4 Fe3+ per 100 eV for photons respectively. However for stock gel which was kept for 5 days preirradiation the G value decreased to 36.6±1.1. The gel shows linearity in OD-dose relationship, energy independence and reproducibility over the dose range investigated. Auto-oxidation of ferrous ions resulted in optical density changes of less than 1.5% per day.
引用
收藏
页码:135 / 140
页数:5
相关论文
共 50 条
  • [41] Comparison of 3D dose measurements in ferrous xylenol orange gels with mapcheck diode array and Pinnacle3 dose calculations
    Jordan, K.
    Babic, S.
    Chen, J.
    Battista, J.
    MEDICAL PHYSICS, 2007, 34 (06) : 2428 - 2428
  • [42] IMAGING OF ABSORBED DOSE IN RADIOTHERAPY BY A POLYMER GEL DOSIMETER
    Vanossi, E.
    Gambarini, G.
    Carrara, M.
    Mariani, M.
    Negri, A.
    ASTROPARTICLE, PARTICLE AND SPACE PHYSICS, DETECTORS AND MEDICAL PHYSICS APPLICATIONS, 2008, 4 : 689 - +
  • [43] Characterisation of high Mr wheat glutenin polymers by agarose gel electrophoresis and dynamic light scattering
    Egorov, TA
    Odintsova, TI
    Shewry, PR
    Tatham, AS
    FEBS LETTERS, 1998, 434 (1-2) : 215 - 217
  • [44] MR IMAGING OF ABSORBED DOSE DISTRIBUTIONS FOR RADIOTHERAPY USING FERROUS SULFATE GELS
    OLSSON, LE
    FRANSSON, A
    ERICSSON, A
    MATTSSON, S
    PHYSICS IN MEDICINE AND BIOLOGY, 1990, 35 (12): : 1623 - 1631
  • [45] IMPROVED MEASUREMENT OF MONOCLONAL PARAPROTEINS IN SERUM USING AGAROSE-GEL ELECTROPHORESIS
    DENNIS, PM
    BIEGLER, B
    PAPAS, R
    ANNALS OF CLINICAL BIOCHEMISTRY, 1987, 24 : 73 - 76
  • [46] QUANTITATIVE MEASUREMENT OF LIPOPROTEIN SURFACE-CHARGE BY AGAROSE-GEL ELECTROPHORESIS
    SPARKS, DL
    PHILLIPS, MC
    JOURNAL OF LIPID RESEARCH, 1992, 33 (01) : 123 - 130
  • [47] DETECTION AND MEASUREMENT OF FACTOR VIII ANTIBODIES IN AN AGAROSE-GEL - MODIFIED METHOD
    RAINSFORD, SG
    HALL, A
    BRITISH JOURNAL OF HAEMATOLOGY, 1976, 33 (02) : 309 - 309
  • [48] A colorimetric agarose gel for formaldehyde measurement based on nanotechnology involving Tollens reaction
    Zeng, Jing-bin
    Fan, Shi-guang
    Zhao, Cui-ying
    Wang, Qian-ru
    Zhou, Ting-yao
    Chen, Xi
    Yan, Zi-feng
    Li, Yan-peng
    Xing, Wei
    Wang, Xu-dong
    CHEMICAL COMMUNICATIONS, 2014, 50 (60) : 8121 - 8123
  • [49] Effects of the pre-irradiation storage procedure on the dose response of a Fricke xylenol orange gel dosimeter
    Liosi, Giulia Maria
    Giacobbo, Francesca
    Pignoli, Emanuele
    Carrara, Mauro
    Gambarini, Grazia
    Mariani, Mario
    NUKLEONIKA, 2015, 60 (03) : 603 - 607
  • [50] How Xylenol Orange and Ferrous Ammonium Sulphate Influence the Dosimetric Properties of PVA-GTA Fricke Gel Dosimeters: A Spectrophotometric Study
    Scotti, Martina
    Arosio, Paolo
    Brambilla, Elisa
    Gallo, Salvatore
    Lenardi, Cristina
    Locarno, Silvia
    Orsini, Francesco
    Pignoli, Emanuele
    Pedicone, Luca
    Veronese, Ivan
    GELS, 2022, 8 (04)