Study on characteristic of Fricke xylenol gel dosimeter: application for dose evaluation in radiotherapy

被引:3
|
作者
Choosin, P. [1 ]
Tippayamontri, T. [2 ]
Ninlaphruk, S. [1 ]
Pungkun, V [1 ]
机构
[1] Off Atoms Peace, Regulatory Tech Support Div, Ionising Radiat Metrol Grp, Bangkok, Thailand
[2] Chulalongkorn Univ, Fac Allied Hlth Sci, Dept Radiol Technol & Med Phys, Bangkok, Thailand
关键词
D O I
10.1088/1742-6596/1285/1/012029
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Accurate assessment of the radiation absorbed dose delivered to a tumor and different organs is a potentially importance issue in clinical radiotherapy. The aim of this study is to evaluate the effectiveness of the Fricke Xylenol Gel dosimeter (FXG) to the gamma radiation from Co-60. With this aim, the dose response of FXG and its behavior have been investigated. The sensitivity and accuracy of FXG were validated by irradiating FXG with the gamma radiation at 1-200 Gy. To evaluate the long- and short-term consistency and reproducibility of FXG, the optical density was measured at 24, 48 and 120 h after irradiation. Light absorbance spectra were analyzed from 350-700 nm. Spectrophotometric measurement of FXG demonstrated the linearity up to 30 Gy, and then gradually reached a plateau. FXG showed a good stability over a period of 120 h after exposure to gamma radiation. FXG showed a high reproducibility which is in comparable to that of obtained from the ionization chamber. The FXG showed high accuracy, sensitivity and reproducibility, thus enabling determination of absorbed dose from the external beam radiotherapy.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Temperature dependence on the dose response of the Fricke-gelatin-xylenol orange gel dosimeter
    Davies, J. B.
    Baldock, C.
    RADIATION PHYSICS AND CHEMISTRY, 2010, 79 (05) : 660 - 662
  • [2] Study of the effect of laponite on Fricke xylenol orange gel dosimeter by optical techniques
    Gallo, Salvatore
    Cremonesi, Luca
    Gambarini, Grazia
    Ianni, Luca
    Lenardi, Cristina
    Argentiere, Simona
    Bettega, Daniela
    Gargano, Marco
    Ludwig, Nicola
    Veronese, Ivan
    SENSORS AND ACTUATORS B-CHEMICAL, 2018, 272 : 618 - 625
  • [3] Effect of perchloric acid on the performance of the Fricke xylenol gel dosimeter
    El Gohary, M. I.
    Soliman, Y. S.
    Amin, E. A.
    Gawad, M. H. Abdel
    Desouky, O. S.
    APPLIED RADIATION AND ISOTOPES, 2016, 113 : 66 - 69
  • [4] Thermoplastic Mask Influence with High Energy Electron Radiotherapy Evaluated by the Fricke Xylenol Gel Chemical Dosimeter
    Moreira, M. V.
    Petchevist, P. C. D.
    de Almeida, A.
    APPLICATION OF ACCELERATORS IN RESEARCH AND INDUSTRY, 2009, 1099 : 472 - +
  • [5] Electron Beam Quality Determination Through Fricke Xylenol Gel Dosimeter
    Petchevist, P. C. D.
    Moreira, M., V
    de Almeida, A.
    APPLICATION OF ACCELERATORS IN RESEARCH AND INDUSTRY, 2009, 1099 : 106 - +
  • [6] Beta planar source quality assurance with the Fricke xylenol gel dosimeter
    Alva-Sanchez, Mirko S.
    de Oliveira, Lucas N.
    Petchevist, Paulo C.
    Moreira, Marco V.
    de Almeida, Adelaide
    RADIATION PHYSICS AND CHEMISTRY, 2014, 96 : 56 - 59
  • [7] Fricke-gel dosimeter: overview of Xylenol Orange chemical behavior
    Liosi, G. M.
    Dondi, D.
    Vander Griend, D. A.
    Lazzaroni, S.
    D'Agostino, G.
    Mariani, M.
    RADIATION PHYSICS AND CHEMISTRY, 2017, 140 : 74 - 77
  • [8] Sensitivity and stability of the Fricke-gelatin-xylenol orange gel dosimeter
    Davies, J. B.
    Baldock, C.
    RADIATION PHYSICS AND CHEMISTRY, 2008, 77 (06) : 690 - 696
  • [9] Effects of the pre-irradiation storage procedure on the dose response of a Fricke xylenol orange gel dosimeter
    Liosi, Giulia Maria
    Giacobbo, Francesca
    Pignoli, Emanuele
    Carrara, Mauro
    Gambarini, Grazia
    Mariani, Mario
    NUKLEONIKA, 2015, 60 (03) : 603 - 607
  • [10] A study on Fricke-PVA-xylenol orange hydrogel dosimeter for E-beam radiotherapy
    Cao Fangqi
    Yang Liming
    Chen Jie
    Lin Han
    Fan Jinchen
    Rong Liang
    Luo Wenyun
    Zha Yuanzi
    Wu Guohua
    NUCLEAR SCIENCE AND TECHNIQUES, 2009, 20 (03) : 152 - 156