Study on characteristic of Fricke xylenol gel dosimeter: application for dose evaluation in radiotherapy

被引:3
|
作者
Choosin, P. [1 ]
Tippayamontri, T. [2 ]
Ninlaphruk, S. [1 ]
Pungkun, V [1 ]
机构
[1] Off Atoms Peace, Regulatory Tech Support Div, Ionising Radiat Metrol Grp, Bangkok, Thailand
[2] Chulalongkorn Univ, Fac Allied Hlth Sci, Dept Radiol Technol & Med Phys, Bangkok, Thailand
关键词
D O I
10.1088/1742-6596/1285/1/012029
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Accurate assessment of the radiation absorbed dose delivered to a tumor and different organs is a potentially importance issue in clinical radiotherapy. The aim of this study is to evaluate the effectiveness of the Fricke Xylenol Gel dosimeter (FXG) to the gamma radiation from Co-60. With this aim, the dose response of FXG and its behavior have been investigated. The sensitivity and accuracy of FXG were validated by irradiating FXG with the gamma radiation at 1-200 Gy. To evaluate the long- and short-term consistency and reproducibility of FXG, the optical density was measured at 24, 48 and 120 h after irradiation. Light absorbance spectra were analyzed from 350-700 nm. Spectrophotometric measurement of FXG demonstrated the linearity up to 30 Gy, and then gradually reached a plateau. FXG showed a good stability over a period of 120 h after exposure to gamma radiation. FXG showed a high reproducibility which is in comparable to that of obtained from the ionization chamber. The FXG showed high accuracy, sensitivity and reproducibility, thus enabling determination of absorbed dose from the external beam radiotherapy.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Fricke gel dosimeter as a tool in quality assurance of the radiotherapy treatment plans
    Soliman, Yasser S.
    El Gohary, M. I.
    Gawad, M. H. Abdel
    Amin, E. A.
    Desouky, O. S.
    APPLIED RADIATION AND ISOTOPES, 2017, 120 : 126 - 132
  • [22] Study of Fricke-Gel Dosimeter Calibration for Attaining Precise Measurements of the Absorbed Dose
    Liosi, G. M.
    Gambarini, G.
    Artuso, E.
    Benedini, S.
    Macerata, E.
    Giacobbo, F.
    Gargano, M.
    Ludwig, N.
    Carrara, M.
    Pignoli, E.
    Mariani, M.
    2015 4TH INTERNATIONAL CONFERENCE ON ADVANCEMENTS IN NUCLEAR INSTRUMENTATION MEASUREMENT METHODS AND THEIR APPLICATIONS (ANIMMA), 2015,
  • [23] Study of the Absorption Spectra of Fricke Xylenol Orange Gel Dosimeters
    Gambarini, G.
    Liosi, G. M.
    Artuso, E.
    Giacobbo, F.
    Mariani, M.
    Brambilla, L.
    Castiglioni, C.
    Carrara, M.
    Pignoli, E.
    2015 4TH INTERNATIONAL CONFERENCE ON ADVANCEMENTS IN NUCLEAR INSTRUMENTATION MEASUREMENT METHODS AND THEIR APPLICATIONS (ANIMMA), 2015,
  • [24] Fricke gel dosimeter with improved sensitivity for low-dose-level measurements
    Valente, Mauro
    Molina, Wladimir
    Carrizales Silva, Lila
    Figueroa, Rodolfo
    Malano, Francisco
    Perez, Pedro
    Santibanez, Mauricio
    Vedelago, Jose
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2016, 17 (04): : 402 - 417
  • [25] 137Cs source dose distribution using the Fricke Xylenol Gel dosimetry
    Sato, R.
    De Almeida, A.
    Moreira, M. V.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2009, 267 (05): : 842 - 845
  • [26] IMAGING OF ABSORBED DOSE IN RADIOTHERAPY BY A POLYMER GEL DOSIMETER
    Vanossi, E.
    Gambarini, G.
    Carrara, M.
    Mariani, M.
    Negri, A.
    ASTROPARTICLE, PARTICLE AND SPACE PHYSICS, DETECTORS AND MEDICAL PHYSICS APPLICATIONS, 2008, 4 : 689 - +
  • [27] Mycosis Fungoides electron beam absorbed dose distribution using Fricke xylenol gel dosimetry
    da Silveira, Michely C.
    Sampaio, Francisco G. A.
    Petchevist, Paulo C. D.
    de Oliveira, Andre L.
    de Almeida, Adelaide
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2011, 269 (24): : 3137 - 3140
  • [28] Evaluation of the application of NIPAM gel dosimeter to quantify dynamic dose effects
    Sun, J. C.
    Tsang, Y. W.
    Hsieh, B. T.
    Cheng, K. Y.
    RADIOTHERAPY AND ONCOLOGY, 2019, 133 : S938 - S939
  • [29] FRICKE GEL DOSIMETER TISSUE-EQUIVALENCE: A MONTE CARLO STUDY
    Valente, M.
    Bartesaghi, G.
    Gambarini, G.
    Brusa, D.
    Castellano, G.
    Carrara, M.
    ASTROPARTICLE, PARTICLE AND SPACE PHYSICS, DETECTORS AND MEDICAL PHYSICS APPLICATIONS, 2008, 4 : 605 - +
  • [30] Study of optical absorbance and MR relaxation of Fricke xylenol orange gel dosimeters
    Gambarini, G.
    Veronese, I.
    Bettinelli, L.
    Felisi, M.
    Gargano, M.
    Ludwig, N.
    Lenardi, C.
    Carrara, M.
    Collura, G.
    Gallo, S.
    Longo, A.
    Marrale, M.
    Tranchina, L.
    d'Errico, F.
    RADIATION MEASUREMENTS, 2017, 106 : 622 - 627