Study on characteristic of Fricke xylenol gel dosimeter: application for dose evaluation in radiotherapy

被引:3
|
作者
Choosin, P. [1 ]
Tippayamontri, T. [2 ]
Ninlaphruk, S. [1 ]
Pungkun, V [1 ]
机构
[1] Off Atoms Peace, Regulatory Tech Support Div, Ionising Radiat Metrol Grp, Bangkok, Thailand
[2] Chulalongkorn Univ, Fac Allied Hlth Sci, Dept Radiol Technol & Med Phys, Bangkok, Thailand
关键词
D O I
10.1088/1742-6596/1285/1/012029
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Accurate assessment of the radiation absorbed dose delivered to a tumor and different organs is a potentially importance issue in clinical radiotherapy. The aim of this study is to evaluate the effectiveness of the Fricke Xylenol Gel dosimeter (FXG) to the gamma radiation from Co-60. With this aim, the dose response of FXG and its behavior have been investigated. The sensitivity and accuracy of FXG were validated by irradiating FXG with the gamma radiation at 1-200 Gy. To evaluate the long- and short-term consistency and reproducibility of FXG, the optical density was measured at 24, 48 and 120 h after irradiation. Light absorbance spectra were analyzed from 350-700 nm. Spectrophotometric measurement of FXG demonstrated the linearity up to 30 Gy, and then gradually reached a plateau. FXG showed a good stability over a period of 120 h after exposure to gamma radiation. FXG showed a high reproducibility which is in comparable to that of obtained from the ionization chamber. The FXG showed high accuracy, sensitivity and reproducibility, thus enabling determination of absorbed dose from the external beam radiotherapy.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] Clinical application of the Fricke-glucomannan gel dosimeter for high-dose-rate 192Ir brachytherapy
    Noda, S.
    Suzuki, Y.
    Hoshino, Y.
    Furukawa, S.
    Katoh, H.
    Kurotaki, K.
    Nakano, T.
    PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (14): : 3985 - 3993
  • [32] Study of light transmittance from layers of Fricke-xylenol-orange-gel dosimeters
    Gambarini, G
    Birattari, C
    Mariani, M
    Marchesini, R
    Pirola, L
    Prestini, P
    Sella, M
    Tomatis, S
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2004, 213 : 321 - 324
  • [33] 8 and 10 MeV Electron Beams Small Field-Size Dosimetric Parameters Through the Fricke Xylenol Gel Dosimeter
    Sampaio, Francisco G. A.
    de Oliveira, Lucas N.
    Moreira, Marcos V.
    Petchevist, Paulo C. D.
    de Almeida, Carlos E.
    de Almeida, Adelaide
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2013, 60 (02) : 572 - 577
  • [34] Characterisation of a Ferrous Agarose Xylenol ( FAX ) gel for radiotherapy dose measurement
    Lee Hon Leong
    S. Kandaiya
    Ng Bong Seng
    Australasian Physics & Engineering Sciences in Medicine, 2007, 30 : 135 - 140
  • [35] Characterisation of a Ferrous Agarose Xylenol (FAX) gel for radiotherapy dose measurement
    Leong, Lee Hon
    Kandaiya, S.
    Seng, Ng Bong
    AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2007, 30 (02) : 135 - 140
  • [36] Development and characterization of a Fricke gel dosimeter for precise measurement in low-dose photon fields
    Saeedi-Sini, Seyed Amir
    Sina, Sedigheh
    Sadeghi, Mohammad Hossein
    Farajzadeh, Ebrahim
    JOURNAL OF INSTRUMENTATION, 2024, 19 (06):
  • [37] Enhancing the longevity of three-dimensional dose in a diffusion-controlled Fricke gel dosimeter
    Babu, S. Ebenezer Suman
    Singh, I. Rabi Raja
    Poornima, C. G.
    Ravindran, B. Paul
    JOURNAL OF CANCER RESEARCH AND THERAPEUTICS, 2015, 11 (03) : 580 - 585
  • [38] A preliminary study of multispectral Cherenkov imaging and a Fricke-xylenol orange gel film (MCIFF) for online, absolute dose measurement
    Han, Haonan
    Geng, Changran
    Deng, Xinping
    Li, Jun
    Shu, Diyun
    Tang, Xiaobin
    MEDICAL PHYSICS, 2024, 51 (05) : 3734 - 3745
  • [39] Evaluation of all dose components in the LVR-15 reactor epithermal neutron beam using Fricke gel dosimeter layers
    Bartesaghi, G.
    Burian, J.
    Gambarini, G.
    Marek, M.
    Negri, A.
    Viererbl, L.
    APPLIED RADIATION AND ISOTOPES, 2009, 67 (7-8) : S199 - S201
  • [40] End-to-end quality assurance for stereotactic radiotherapy with Fricke-Xylenol orange-Gelatin gel dosimeter and dual-wavelength cone-beam optical CT readout
    Rousseau, Alice
    Stien, Christel
    Gouriou, Jean
    Bordy, Jean-Marc
    Boissonnat, Guillaume
    Chabert, Isabelle
    Dufreneix, Stephane
    Blideanu, Valentin
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2023, 113