Attenuation images of optical CT using Fricke xylenol orange gel for dose mapping in radiotherapy

被引:0
|
作者
Tavares, P. V. S. [1 ]
Diniz, R. E. [1 ]
Rodrigues Jr, O. [1 ]
Campos, L. L. [1 ]
机构
[1] Energy & Nucl Res Inst, Ionizing Radiat Metrol Ctr, Ave Prof Lineu Prestes,2242, BR-05508000 Sao Paulo, SP, Brazil
基金
巴西圣保罗研究基金会;
关键词
3D dosimetry; Fricke gel; Optical CT; ITERATIVE RECONSTRUCTION ALGORITHM; GELATIN GEL; DISTRIBUTIONS; SCANNER; SIMULATIONS; DOSIMETER;
D O I
10.1016/j.radphyschem.2024.112016
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The Fricke gel dosimeter, a gel-based solution containing ferrous ions, can be used for three-dimensional dosimetry by adding xylenol orange to the solution. This changes the optical properties, affecting radiation absorption. These gel dosimeters are recommended for clinical use, and 3D dosimetry uses optical computed tomography (OCT) to analyze reconstructed images. Advancements in radiotherapy focus on accurate irradiation while reducing doses to nearby tissues. This study uses modified FXO gel for 3D dosimetry, utilizing non-toxic, easy-to-handle reagents and optical CT Vista 16 equipment. The experiment aims to characterize the system's practicality and evaluate the impact of lead filters on attenuation values. The study also examines trends in attenuation values for different thicknesses of lead shields, enhancing our understanding of the relationship between attenuation and dose using optical CT. To prevent artifacts, a modified FXO gel was created by introducing a variation of XO in the preparation. The ideal concentration of XO is 0.01 mM to prevent distortions within the dose range of 1 Gy-10 Gy. A calibration system using FXO gel can be developed by comparing the maximum irradiation dose with the attenuation observed in the gel. The modified gel showed a sensitivity of 5.5.10-3 +/- 2.6.10-4 cm- 1/Gy and a starting dose of 4.2 Gy. Two samples were tested using different configurations of lead filters, with the central holes showing dose peaks of 4.72 Gy, 4.57 Gy, and 4.32 Gy, respectively. The results suggest the feasibility of producing modified FXO gels for examination in optical CT systems and their potential application in radiotherapy systems. Future research is being conducted in clinical irradiation to facilitate comparison with system designs.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Study of the effect of laponite on Fricke xylenol orange gel dosimeter by optical techniques
    Gallo, Salvatore
    Cremonesi, Luca
    Gambarini, Grazia
    Ianni, Luca
    Lenardi, Cristina
    Argentiere, Simona
    Bettega, Daniela
    Gargano, Marco
    Ludwig, Nicola
    Veronese, Ivan
    SENSORS AND ACTUATORS B-CHEMICAL, 2018, 272 : 618 - 625
  • [2] Study of optical absorbance and MR relaxation of Fricke xylenol orange gel dosimeters
    Gambarini, G.
    Veronese, I.
    Bettinelli, L.
    Felisi, M.
    Gargano, M.
    Ludwig, N.
    Lenardi, C.
    Carrara, M.
    Collura, G.
    Gallo, S.
    Longo, A.
    Marrale, M.
    Tranchina, L.
    d'Errico, F.
    RADIATION MEASUREMENTS, 2017, 106 : 622 - 627
  • [3] Study on characteristic of Fricke xylenol gel dosimeter: application for dose evaluation in radiotherapy
    Choosin, P.
    Tippayamontri, T.
    Ninlaphruk, S.
    Pungkun, V
    INTERNATIONAL NUCLEAR SCIENCE AND TECHNOLOGY CONFERENCE, 2019, 1285
  • [4] Temperature dependence on the dose response of the Fricke-gelatin-xylenol orange gel dosimeter
    Davies, J. B.
    Baldock, C.
    RADIATION PHYSICS AND CHEMISTRY, 2010, 79 (05) : 660 - 662
  • [5] Study of the Absorption Spectra of Fricke Xylenol Orange Gel Dosimeters
    Gambarini, G.
    Liosi, G. M.
    Artuso, E.
    Giacobbo, F.
    Mariani, M.
    Brambilla, L.
    Castiglioni, C.
    Carrara, M.
    Pignoli, E.
    2015 4TH INTERNATIONAL CONFERENCE ON ADVANCEMENTS IN NUCLEAR INSTRUMENTATION MEASUREMENT METHODS AND THEIR APPLICATIONS (ANIMMA), 2015,
  • [6] Fricke-Xylenol orange-Gelatin gel characterization with dual wavelength cone-beam optical CT scanner for applications in stereotactic and dynamic radiotherapy
    Rousseau, Alice
    Stien, Christel
    Bordy, Jean-Marc
    Blideanu, Valentin
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2022, 97 : 1 - 12
  • [7] Fricke-gel dosimeter: overview of Xylenol Orange chemical behavior
    Liosi, G. M.
    Dondi, D.
    Vander Griend, D. A.
    Lazzaroni, S.
    D'Agostino, G.
    Mariani, M.
    RADIATION PHYSICS AND CHEMISTRY, 2017, 140 : 74 - 77
  • [8] Sensitivity and stability of the Fricke-gelatin-xylenol orange gel dosimeter
    Davies, J. B.
    Baldock, C.
    RADIATION PHYSICS AND CHEMISTRY, 2008, 77 (06) : 690 - 696
  • [9] Effects of the pre-irradiation storage procedure on the dose response of a Fricke xylenol orange gel dosimeter
    Liosi, Giulia Maria
    Giacobbo, Francesca
    Pignoli, Emanuele
    Carrara, Mauro
    Gambarini, Grazia
    Mariani, Mario
    NUKLEONIKA, 2015, 60 (03) : 603 - 607
  • [10] Assessment of dosimetric sensitivity enhancement of xylenol orange Fricke gel by AuNPs: optical and MR imaging investigation
    Lima, I. S.
    Silveira, M. A.
    Pavoni, J.
    Guidelli, J. E.
    Garrido, E. C. S.
    Baffa, O.
    PHYSICS IN MEDICINE AND BIOLOGY, 2023, 68 (22):