Attenuation images of optical CT using Fricke xylenol orange gel for dose mapping in radiotherapy

被引:0
|
作者
Tavares, P. V. S. [1 ]
Diniz, R. E. [1 ]
Rodrigues Jr, O. [1 ]
Campos, L. L. [1 ]
机构
[1] Energy & Nucl Res Inst, Ionizing Radiat Metrol Ctr, Ave Prof Lineu Prestes,2242, BR-05508000 Sao Paulo, SP, Brazil
基金
巴西圣保罗研究基金会;
关键词
3D dosimetry; Fricke gel; Optical CT; ITERATIVE RECONSTRUCTION ALGORITHM; GELATIN GEL; DISTRIBUTIONS; SCANNER; SIMULATIONS; DOSIMETER;
D O I
10.1016/j.radphyschem.2024.112016
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The Fricke gel dosimeter, a gel-based solution containing ferrous ions, can be used for three-dimensional dosimetry by adding xylenol orange to the solution. This changes the optical properties, affecting radiation absorption. These gel dosimeters are recommended for clinical use, and 3D dosimetry uses optical computed tomography (OCT) to analyze reconstructed images. Advancements in radiotherapy focus on accurate irradiation while reducing doses to nearby tissues. This study uses modified FXO gel for 3D dosimetry, utilizing non-toxic, easy-to-handle reagents and optical CT Vista 16 equipment. The experiment aims to characterize the system's practicality and evaluate the impact of lead filters on attenuation values. The study also examines trends in attenuation values for different thicknesses of lead shields, enhancing our understanding of the relationship between attenuation and dose using optical CT. To prevent artifacts, a modified FXO gel was created by introducing a variation of XO in the preparation. The ideal concentration of XO is 0.01 mM to prevent distortions within the dose range of 1 Gy-10 Gy. A calibration system using FXO gel can be developed by comparing the maximum irradiation dose with the attenuation observed in the gel. The modified gel showed a sensitivity of 5.5.10-3 +/- 2.6.10-4 cm- 1/Gy and a starting dose of 4.2 Gy. Two samples were tested using different configurations of lead filters, with the central holes showing dose peaks of 4.72 Gy, 4.57 Gy, and 4.32 Gy, respectively. The results suggest the feasibility of producing modified FXO gels for examination in optical CT systems and their potential application in radiotherapy systems. Future research is being conducted in clinical irradiation to facilitate comparison with system designs.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] Novel GTA-PVA Fricke gels for three-dimensional dose mapping in radiotherapy
    d'Errico, Francesco
    Lazzeri, Luigi
    Dondi, Daniele
    Mariani, Mario
    Marrale, Maurizio
    Souza, Susana O.
    Gambarini, Grazia
    RADIATION MEASUREMENTS, 2017, 106 : 612 - 617
  • [42] An intercomparison of RPC verified IMRT plans with ferrous xylenol orange gels and optical CT scanners
    Babic, S.
    Battista, J.
    Jordan, K.
    MEDICAL PHYSICS, 2007, 34 (06) : 2417 - 2417
  • [43] 3D characterization of small megavoltage radiation fields using an optical CT scanner with ferrous xylenol orange gels
    McNiven, A.
    Babic, S.
    Jordan, K.
    Battista, J.
    MEDICAL PHYSICS, 2007, 34 (06) : 2401 - 2401
  • [44] Investigation for Monte Carlo simulation with geometric simplification of the GammaCell 220 irradiator with experimental measurements using Fricke xylenol gel (FXG)
    Rodrigues, P. S.
    Burin, A. L.
    Talacimon, C. F.
    Medeiros, I. M. M. A.
    Pereira, J. J. N.
    Teodoro, L. E. H.
    Rigo, M. E. Z.
    Gesserame, M. M. F.
    Tavares, P. V. S.
    Martins, A. C.
    Souza, C. D.
    Zeituni, C. A.
    Rodrigues Jr, O.
    Rostelato, M. E. C. M.
    RADIATION PHYSICS AND CHEMISTRY, 2024, 224
  • [45] An apparent threshold dose response in ferrous xylenol-orange gel dosimeters when scanned with a yellow light source
    Babic, Steven
    Battista, Jerry
    Jordan, Kevin
    PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (06): : 1637 - 1650
  • [46] Characterization of ferrous-xylenol orange-polyvinyl alcohol gel for gamma dosimetry using spectroscopy
    Sedighi, Mahsa
    Edalatkhah, Elham
    Taherparvar, Payvand
    RADIOCHIMICA ACTA, 2024, 112 (11) : 923 - 928
  • [47] A method for obtaining three-dimensional measurements of HDR brachytherapy dose distributions using Fricke gel dosimeters and optical computed tomography
    Andre Asena
    Sanna Nilsson
    Shaun T. Smith
    Tanya Kairn
    Scott B. Crowe
    Jamie V. Trapp
    Australasian Physical & Engineering Sciences in Medicine, 2019, 42 : 221 - 226
  • [48] A method for obtaining three-dimensional measurements of HDR brachytherapy dose distributions using Fricke gel dosimeters and optical computed tomography
    Asena, Andre
    Nilsson, Sanna
    Smith, Shaun T.
    Kairn, Tanya
    Crowe, Scott B.
    Trapp, Jamie V.
    AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2019, 42 (01) : 221 - 226
  • [49] Gamma/neutron dose evaluation using Fricke gel and alanine gel dosimeters to be applied in boron neutron capture therapy
    Mangueira, T. F.
    Silva, C. F.
    Coelho, P. R. P.
    Campos, L. L.
    APPLIED RADIATION AND ISOTOPES, 2010, 68 (4-5) : 791 - 794