The Fricke gel dosimeter, a gel-based solution containing ferrous ions, can be used for three-dimensional dosimetry by adding xylenol orange to the solution. This changes the optical properties, affecting radiation absorption. These gel dosimeters are recommended for clinical use, and 3D dosimetry uses optical computed tomography (OCT) to analyze reconstructed images. Advancements in radiotherapy focus on accurate irradiation while reducing doses to nearby tissues. This study uses modified FXO gel for 3D dosimetry, utilizing non-toxic, easy-to-handle reagents and optical CT Vista 16 equipment. The experiment aims to characterize the system's practicality and evaluate the impact of lead filters on attenuation values. The study also examines trends in attenuation values for different thicknesses of lead shields, enhancing our understanding of the relationship between attenuation and dose using optical CT. To prevent artifacts, a modified FXO gel was created by introducing a variation of XO in the preparation. The ideal concentration of XO is 0.01 mM to prevent distortions within the dose range of 1 Gy-10 Gy. A calibration system using FXO gel can be developed by comparing the maximum irradiation dose with the attenuation observed in the gel. The modified gel showed a sensitivity of 5.5.10-3 +/- 2.6.10-4 cm- 1/Gy and a starting dose of 4.2 Gy. Two samples were tested using different configurations of lead filters, with the central holes showing dose peaks of 4.72 Gy, 4.57 Gy, and 4.32 Gy, respectively. The results suggest the feasibility of producing modified FXO gels for examination in optical CT systems and their potential application in radiotherapy systems. Future research is being conducted in clinical irradiation to facilitate comparison with system designs.
引用
收藏
页数:8
相关论文
共 50 条
  • [11] RapidArc Dose Verification Using Ferrous Xylenol-Orange Gels and Optical CT
    Babic, S.
    Hajdok, G.
    Jordan, K.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [12] Xylenol orange functionalised polymers to overcome diffusion in Fricke gel radiation dosimeters
    Boase, Nathan R. B.
    Smith, Shaun T.
    Masters, Kye-Simeon
    Hosokawa, Kazuyuki
    Crowe, Scott B.
    Trapp, Jamie V.
    REACTIVE & FUNCTIONAL POLYMERS, 2018, 132 : 81 - 88
  • [13] Fricke xylenol gel characterization using a photoacustic technique
    Caldeira, A. M. F.
    de Almeida, A.
    Neto, A. M.
    Baesso, M. L.
    Bento, A. C.
    Silva, M. A.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 582 (02): : 484 - 488
  • [14] Optical images of dose distributions in gel-fricke: Dosimetric performances of the gel
    Luciani, A. M.
    Palma, A.
    Adorante, N.
    Barone, P.
    Grande, S.
    Ranghiasci, C.
    Rosi, A.
    Guidoni, L.
    Viti, V.
    RADIATION PROTECTION DOSIMETRY, 2006, 122 (1-4) : 455 - 456
  • [15] Fricke gel xylenol orange dosimeter layers for stereotactic radiosurgery: A preliminary approach
    Perez, P.
    Torres, P. Rico
    Bruna, A.
    Brunetto, M.
    Aon, E.
    Franco, D.
    Mattea, F.
    Figueroa, R.
    Santibanez, M.
    Valente, M.
    APPLIED RADIATION AND ISOTOPES, 2021, 178
  • [16] 137Cs source dose distribution using the Fricke Xylenol Gel dosimetry
    Sato, R.
    De Almeida, A.
    Moreira, M. V.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2009, 267 (05): : 842 - 845
  • [17] Study of light transmittance from layers of Fricke-xylenol-orange-gel dosimeters
    Gambarini, G
    Birattari, C
    Mariani, M
    Marchesini, R
    Pirola, L
    Prestini, P
    Sella, M
    Tomatis, S
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2004, 213 : 321 - 324
  • [18] Mycosis Fungoides electron beam absorbed dose distribution using Fricke xylenol gel dosimetry
    da Silveira, Michely C.
    Sampaio, Francisco G. A.
    Petchevist, Paulo C. D.
    de Oliveira, Andre L.
    de Almeida, Adelaide
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2011, 269 (24): : 3137 - 3140
  • [19] End-to-end quality assurance for stereotactic radiotherapy with Fricke-Xylenol orange-Gelatin gel dosimeter and dual-wavelength cone-beam optical CT readout
    Rousseau, Alice
    Stien, Christel
    Gouriou, Jean
    Bordy, Jean-Marc
    Boissonnat, Guillaume
    Chabert, Isabelle
    Dufreneix, Stephane
    Blideanu, Valentin
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2023, 113
  • [20] A preliminary study of multispectral Cherenkov imaging and a Fricke-xylenol orange gel film (MCIFF) for online, absolute dose measurement
    Han, Haonan
    Geng, Changran
    Deng, Xinping
    Li, Jun
    Shu, Diyun
    Tang, Xiaobin
    MEDICAL PHYSICS, 2024, 51 (05) : 3734 - 3745