Resolution of Biparametric Mixtures Using Bead Injection Spectroscopic Flow-through Renewable Surface Sensors

被引:0
|
作者
M. J. Ruedas-Rama
A. Ruiz-Medina
A. Molina-Díaz
机构
[1] University of Jaén,Department of Physical and Analytical Chemistry, Faculty of Experimental Sciences
来源
Analytical Sciences | 2005年 / 21卷
关键词
D O I
暂无
中图分类号
学科分类号
摘要
A new, sensitive and simple bead injection spectroscopy-flow injection analysis (BIS-FIA) sensor with spectrophotometric detection, using a commercially available flow-cell, is described to the determination of biparametric mixtures. As an analytical model, the metallic mixture Cu(II) and Zn(II) has been chosen. The flow-cell (Hellma 138-OS) is filled by injecting in the flow system 300 μl of a homogeneous bead suspension of an anion exchanger gel (Sephadex QAE A-25) previously loaded with the chromogenic reagent 2-carboxyl-2-hydroxy-5-sulfoformazylbenzene (Zincon). A sequential reaction of Cu(II) and Zn(II) with Zincon to form two complexes is performed on the bead sensing support and the absorbance is monitored at 627 nm, after two successive injections from the mixture solution. The sample containing these metal ions is injected into the first carrier (deionized water, pH 5.9), and Cu(II) selectively reacts with Zincon on the beads, developing the analytical signal. Then, 600 μl of 2 M HCl is injected to decompose the complex, and the carrier solution is changed. At pH 11 (second carrier) both Cu(II) and Zn(II) react with the chromogenic reagent, the absorbance now corresponding to both analytes. The eluent is again injected to descompose both complexes. After three analyses the sensing bead surface is not regenerated. Then, beads are automatically discarded from the flow cell by reversal of the flow, and instantaneously transported out of the system. So the procedure exploits the combination of the concepts of flow-through renewable sensors with Bead Injection Spectroscopy. Using a sample volume of 1000 μl, the calibration graph for Cu(II) is linear over the range 0.05 to 1 μg ml-1 and for Zn(II) from 0.1 to 1.8 μg ml-1 in the presence of each other. RSDs (%) lower than 5% are obtained for both analytes. The sensor is satisfactorily applied to individual determination or mixture resolution in waters, pharmaceuticals, soils and human hair samples.
引用
收藏
页码:1079 / 1084
页数:5
相关论文
共 39 条
  • [21] Flow-through Chemiluminescence Sensor Using Immobilized Oxidases for the Selective Determination of l-Glutamate in a Flow-Injection System
    Nobutoshi Kiba
    Seiji Ito
    Masaki Tachibana
    Kazue Tani
    Hitoshi Koizumi
    Analytical Sciences, 2001, 17 : 929 - 933
  • [22] Enzymatic Determinations by sequential injection renewable surface reflectance spectrophotometric system using a microchip flow cell
    Wang, JY
    Fang, ZL
    Xu, SK
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2002, 30 (03) : 307 - 311
  • [23] New Potentiometric Sensors Based on Two Competitive Recognition Sites for Determining Tetracycline Residues Using Flow-Through System
    Moreira, Felismina T. C.
    Kamel, Ayman H.
    Guerreiro, Rafaela L.
    Azevedo, Vera
    Sales, M. Goreti F.
    EUROSENSORS XXIV CONFERENCE, 2010, 5 : 1200 - 1203
  • [24] Vermicomposting organic waste with Eisenia fetida using a continuous flow-through reactor: Investigating five distinct waste mixtures
    Usta, Ayse Nur
    Guven, Huseyin
    JOURNAL OF ENVIRONMENTAL CHEMICAL ENGINEERING, 2024, 12 (06):
  • [25] Flow-through optical fiber sensor for automatic sulfide determination in waters by multisyringe flow injection analysis using solid-phase reflectometry
    Ferrer, L
    de Armas, G
    Miró, M
    Estela, JM
    Cerdà, V
    ANALYST, 2005, 130 (05) : 644 - 651
  • [26] A flow-through fluorimetric sensing device for determination of α- and β-naphthol mixtures using a partial least-squares multivariate calibration approach
    Ortega-Algar, S
    Ramos-Martos, N
    Molina-Díaz, A
    TALANTA, 2003, 60 (2-3) : 313 - 323
  • [27] Novel Flow-through Potentiometric System for Dimethyamine Assessment Using New Ion Exchangers Doped-polymeric Membrane Sensors
    Hassan, Saad S. M.
    Kamel, Ayman H.
    Abd El-Naby, Heba
    ELECTROANALYSIS, 2018, 30 (11) : 2635 - 2643
  • [28] A flow-through solid-phase spectroscopic sensing device implemented with FIA solution measurements in the same flow cell:: determination of binary mixtures of thiamine with ascorbic acid or acetylsalicylic acid
    Ortega-Barrales, P
    Ruiz-Medina, A
    Fernández-de Córdova, ML
    Molina-Díaz, A
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2002, 373 (4-5) : 227 - 232
  • [29] A flow-through solid-phase spectroscopic sensing device implemented with FIA solution measurements in the same flow cell: determination of binary mixtures of thiamine with ascorbic acid or acetylsalicylic acid
    P. Ortega-Barrales
    A. Ruiz-Medina
    Fernández-de M. Córdova
    A. Molina-Díaz
    Analytical and Bioanalytical Chemistry, 2002, 373 : 227 - 232
  • [30] POTENTIOMETRIC FLOW-INJECTION DETERMINATION OF BORON BY USING A FLOW-THROUGH TETRAFLUOROBORATE ION-SELECTIVE POLY(VINYL CHLORIDE) MEMBRANE-ELECTRODE
    IMATO, T
    YOSHIZUKA, T
    ISHIBASHI, N
    ANALYTICA CHIMICA ACTA, 1990, 233 (01) : 139 - 141