A flow-through fluorimetric sensing device for determination of α- and β-naphthol mixtures using a partial least-squares multivariate calibration approach

被引:18
|
作者
Ortega-Algar, S [1 ]
Ramos-Martos, N [1 ]
Molina-Díaz, A [1 ]
机构
[1] Univ Jaen, Fac Expt Sci, Dept Phys & Analyt Chem, E-23071 Jaen, Spain
关键词
alpha-naphthol and beta-naphthol determination; flow-through sensor; PLS multivariate calibration;
D O I
10.1016/S0039-9140(03)00110-3
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A single flow-through optosensor spectrofluorimetric system is proposed for the resolution of mixtures of alpha- and beta-naphthol at mug 1(-1) levels using a partial least-squares (PLS) calibration approach. The sensor was developed in conjunction with a monochannel flow-injection analysis system with fluorimetric detection using Sephadex QAE A-25 resin as an active sorbent substrate in the flow cell and the second derivative of the native synchronous fluorescence spectra of analytes as analytical signal. In the manifold, the solutions of naphthol (at pH 10.0) were injected in a carrier stream of KCl (0. 15 M)/NaOH (10(-2) M). Because of the strong spectral overlap, the mixture could not be resolved by conventional spectrofluorimetry. The non-additive behaviour of the fluorescence signals revealed an interaction in the system, which was not found by working in the solution only (without the sorbent support). This interaction, probably due to the environment of the analytes on the solid phase, made impossible their simultaneous determination. So, the use of synchronous fluorescence spectroscopy or even its derivative signal could not resolve satisfactorily the mixture. The simultaneous determination of both naphthol has been carried out by recording the signal of the second-derivative synchronous fluorescence (Deltalambda = 170 mn) spectra between 200 and 450 nm and a PLS multivariate calibration treatment. The optimum number of factors was selected by using the cross-validation method. After validating the proposed method, it was applied to the determination of these compounds in natural waters with different amounts of each chemical. (C) 2003 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:313 / 323
页数:11
相关论文
共 50 条
  • [1] Stopped-flow fluorimetric determination of amoxycillin and clavulanic acid by partial least-squares multivariate calibration
    de la Peña, AM
    Acedo-Valenzuela, MI
    Espinosa-Mansilla, A
    Sánchez-Maqueda, R
    TALANTA, 2002, 56 (04) : 635 - 642
  • [2] Simultaneous Determination of Colorant Mixtures Used in Cosmetics by Partial Least-Squares Multivariate Calibration Spectrophotometry
    L. F. Capitán-Vallvey
    N. Navas
    R. Avidad
    I. de Orbe
    J. J. Berzas-Nevado
    Analytical Sciences, 1997, 13 : 493 - 496
  • [3] Simultaneous determination of colorant mixtures used in cosmetics by partial least-squares multivariate calibration spectrophotometry
    CapitanVallvey, LF
    Navas, N
    Avidad, R
    deOrbe, I
    BerzasNevado, JJ
    ANALYTICAL SCIENCES, 1997, 13 (03) : 493 - 496
  • [4] DETERMINATION OF BINARY-MIXTURES OF SULFONAMIDES BY PHOTOCHEMICALLY INDUCED FLUORESCENCE USING PARTIAL LEAST-SQUARES MULTIVARIATE CALIBRATION
    PENA, MS
    DELAPENA, AM
    SALINAS, F
    MAHEDERO, MC
    AARON, JJ
    ANALYST, 1994, 119 (06) : 1177 - 1181
  • [5] Simultaneous determination of nafcillin and methicillin by different fluorimetric techniques using partial least-squares calibration
    Murillo, JA
    Alañón, A
    Fernández, P
    de la Peña, AM
    Espinosa-Mansilla, A
    ANALYST, 1998, 123 (05) : 1073 - 1077
  • [6] Synchronous fluorimetric determination of salicylic acid and diflunisal in human serum using partial least-squares calibration
    delaPena, AM
    Moreno, MD
    DuranMeras, I
    Salinas, F
    TALANTA, 1996, 43 (08) : 1349 - 1356
  • [7] Determination of binary mixtures of nitramines by a spectrophotometric method using partial least squares multivariate calibration
    Chaloosi, M
    Gholamian, F
    Zarei, MA
    PROPELLANTS EXPLOSIVES PYROTECHNICS, 2001, 26 (01) : 21 - 25
  • [8] Simultaneous determination of pteridines in multicomponent mixtures using derivative spectrophotometry and partial least-squares calibration
    Espinosa-Mansilla, A
    Duran-Meras, I
    Salinas, F
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1998, 17 (08) : 1325 - 1334
  • [9] Spectrophotometric analysis of α- and β-naphthol mixtures applying partial least-squares method
    Revilla, AL
    Vargas, G
    Havel, J
    CHEMICAL PAPERS-CHEMICKE ZVESTI, 1999, 53 (01): : 34 - 39
  • [10] A NOTE ON THE USE OF THE PARTIAL LEAST-SQUARES METHOD FOR MULTIVARIATE CALIBRATION
    LORBER, A
    KOWALSKI, BR
    APPLIED SPECTROSCOPY, 1988, 42 (08) : 1572 - 1574