POTENTIOMETRIC FLOW-INJECTION DETERMINATION OF BORON BY USING A FLOW-THROUGH TETRAFLUOROBORATE ION-SELECTIVE POLY(VINYL CHLORIDE) MEMBRANE-ELECTRODE

被引:10
|
作者
IMATO, T [1 ]
YOSHIZUKA, T [1 ]
ISHIBASHI, N [1 ]
机构
[1] KYUSHU UNIV,FAC ENGN,DEPT APPL ANALYT CHEM,HIGASHI KU,FUKUOKA 812,JAPAN
关键词
D O I
10.1016/S0003-2670(00)83470-4
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A highly sensitive tetrafluoroborate ion-selective poly(vinyl chloride) membrane electrode was constructed and applied to a detector in the flow-injection determination of boron. Boron at the 10 ng ml-1 level can be determined by converting it to tetrafluoroborate ion in a flow of hydrofluoric acid. A sampling rate of 30 h-1 was achieved with a relative standard deviation of less than 2%. © 1990.
引用
收藏
页码:139 / 141
页数:3
相关论文
共 50 条
  • [1] FLOW-INJECTION DETERMINATION OF BORON BY USING POLY(VINYL CHLORIDE) MEMBRANE-BASED TETRAFLUOROBORATE ION-SELECTIVE ELECTRODE
    IMATO, T
    YOSHIZUKA, T
    ISHIBASHI, N
    [J]. BUNSEKI KAGAKU, 1993, 42 (02) : 91 - 98
  • [2] FLOW-THROUGH SANDWICH PVC MATRIX MEMBRANE-ELECTRODE FOR FLOW-INJECTION ANALYSIS
    ALEGRET, S
    ALONSO, J
    BARTROLI, J
    LIMA, JLFC
    MACHADO, AASC
    PAULIS, JM
    [J]. ANALYTICAL LETTERS PART A-CHEMICAL ANALYSIS, 1985, 18 (18): : 2291 - 2303
  • [3] FLOW-INJECTION ANALYSIS OF NONIONIC SURFACTANTS WITH PLASTICIZED POLY(VINYL CHLORIDE) MEMBRANE-ELECTRODE DETECTOR
    MASADOME, T
    IMATO, T
    ISHIBASHI, N
    [J]. BUNSEKI KAGAKU, 1990, 39 (09) : 519 - 522
  • [4] Flow-injection potentiometric determination of free cadmium ions with a cadmium ion-selective electrode
    Trojanowicz, M
    Alexander, PW
    Brynn Hibbert, D
    [J]. ANALYTICA CHIMICA ACTA, 1998, 370 (2-3) : 267 - 278
  • [5] A NEW POLY(VINYL CHLORIDE) MATRIX MEMBRANE-ELECTRODE FOR MANUAL AND FLOW-INJECTION DETERMINATION OF PILOCARPINE IN SOME PHARMACEUTICAL PREPARATIONS
    ELNEMMA, EM
    [J]. ANALYTICAL LETTERS, 1994, 27 (10) : 1863 - 1874
  • [6] FLOW-INJECTION DETERMINATION OF PHOSPHATE WITH A CADMIUM ION-SELECTIVE ELECTRODE
    DAVEY, DE
    MULCAHY, DE
    OCONNELL, GR
    [J]. TALANTA, 1990, 37 (07) : 683 - 687
  • [7] STUDIES ON THE ELIMINATION OF SULFIDE INTERFERENCE IN THE POTENTIOMETRIC DETERMINATION OF CHLORIDE USING ION-SELECTIVE ELECTRODES IN A FLOW-INJECTION SYSTEM
    ALTUNBULDUK, T
    KOCKER, HMZ
    FRENZEL, W
    [J]. FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1995, 351 (07): : 593 - 598
  • [8] Flow-injection potentiometric detection of phosphates using a metallic cobalt wire ion-selective electrode
    Chen, ZL
    DeMarco, R
    Alexander, PW
    [J]. ANALYTICAL COMMUNICATIONS, 1997, 34 (03): : 93 - 95
  • [9] POTENTIOMETRIC DETERMINATION OF THE BILE PHOSPHATES BY A LEAD ION-SELECTIVE MEMBRANE-ELECTRODE
    CAMPANELLA, L
    DASCENZO, G
    DEANGELIS, G
    TOMASSETTI, M
    [J]. JOURNAL OF CLINICAL CHEMISTRY AND CLINICAL BIOCHEMISTRY, 1981, 19 (08): : 629 - 630
  • [10] Flow-injection potentiometric determination of iron (III) in vitamin formulations using a tubular ion-selective electrode in oxalic medium
    Teixeira, MFD
    Fatibello, O
    Aniceto, C
    Neto, COC
    [J]. LABORATORY ROBOTICS AND AUTOMATION, 1999, 11 (03) : 163 - 168