A flow-through solid-phase spectroscopic sensing device implemented with FIA solution measurements in the same flow cell: determination of binary mixtures of thiamine with ascorbic acid or acetylsalicylic acid

被引:0
|
作者
P. Ortega-Barrales
A. Ruiz-Medina
Fernández-de M. Córdova
A. Molina-Díaz
机构
[1] Department of Physical and Analytical Chemistry,
[2] Faculty of Experimental Sciences,undefined
[3] University of Jaén,undefined
[4] Paraje Las Lagunillas,undefined
[5] s/n,undefined
[6] 23071 Jaén,undefined
[7] Spain,undefined
来源
关键词
Solid-phase spectrophotometry Flow-through optosensor Ascorbic acid Thiamine Acetylsalicylic acid Pharmaceuticals;
D O I
暂无
中图分类号
学科分类号
摘要
A continuous and simple UV-photometric flow-through optosensor has been developed for the simultaneous determination of a binary mixture of two species with different electric charges present at very different concentrations – ascorbic acid (or acetylsalicylic acid) and thiamine. The sensing device is based on the selective sorption and determination of a cationic analyte on a cation-exchange gel (Sephadex SP-C25) while the other, anionic, analyte is determined in the solution among the interstices of the cation-exchange gel in the same flow cell. The analytes arrive in sequence at the sensing zone, which detects their intrinsic absorbance at 253 nm, as a result of on-line separation by use of a minicolumn filled with the same cation-exchange gel as in the cell, and placed before the flow cell. Thiamine is retained in the minicolumn whereas ascorbic acid or acetylsalicylic acid pass through it and produce their signal as a result of absorbance in the interstitial solution among the resin beads. Thiamine is then eluted from the precolumn, transported to the flow cell, and temporarily retained in the sensing zone from this eluted solution. Calibration graphs were linear over the range 3–50, 25–400, and 300–3000 µg mL–1 (600 µL sample volume) and the relative standard deviations were 2.56, 1.85, and 1.25 % for thiamine, ascorbic acid, and acetylsalicylic acid, respectively. The proposed method was satisfactorily applied to the determination of binary mixtures of thiamine with ascorbic acid or acetylsalicylic acid in pharmaceutical preparations and semi-synthetic samples.
引用
收藏
页码:227 / 232
页数:5
相关论文
共 9 条
  • [1] A flow-through solid-phase spectroscopic sensing device implemented with FIA solution measurements in the same flow cell:: determination of binary mixtures of thiamine with ascorbic acid or acetylsalicylic acid
    Ortega-Barrales, P
    Ruiz-Medina, A
    Fernández-de Córdova, ML
    Molina-Díaz, A
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2002, 373 (4-5) : 227 - 232
  • [2] Use of a continuous flow solid-phase spectroscopic sensor using two sensing zones:: Determination of thiamine and ascorbic acid
    Ruiz-Medina, A
    Ortega-Barrales, P
    Fernández-De Córdova, ML
    Molina-Díaz, A
    JOURNAL OF AOAC INTERNATIONAL, 2002, 85 (02) : 369 - 374
  • [3] Determination of ascorbic acid by use of a flow-through solid phase UV spectrophotometric system
    A. Molina-Díaz
    A. Ruiz-Medina
    M. L. Fernández-de Córdova
    Fresenius' Journal of Analytical Chemistry, 1999, 363 : 92 - 97
  • [4] Determination of ascorbic acid by use of a flow-through solid phase UV spectrophotometric system
    Molina-Díaz, A
    Ruiz-Medina, A
    Fernández-de Córdova, ML
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1999, 363 (01): : 92 - 97
  • [5] Implementation of flow-through solid phase spectroscopic transduction with photochemically induced fluorescence:: determination of thiamine
    López-Flores, J
    Córdova, MLFD
    Molina-Díaz, A
    ANALYTICA CHIMICA ACTA, 2005, 535 (1-2) : 161 - 168
  • [6] A flow-through solid phase UV spectrophotometric biparameter sensor for the sequential determination of ascorbic acid and paracetamol
    Ruiz-Medina, A
    Fernández-de Córdova, ML
    Ayora-Cañada, MJ
    Pascual-Reguera, MI
    Molina-Díaz, A
    ANALYTICA CHIMICA ACTA, 2000, 404 (01) : 131 - 139
  • [7] Sensitive determination of adrenaline by means of a flow-through solid phase UV spectrophotometric sensing device
    Medina A.R.
    De Córdova M.L.F.
    Díaz A.M.
    Mikrochimica Acta, 2000, 134 (1-2) : 101 - 105
  • [8] Solid-phase iodine as an oxidant in flow injection analysis: determination of ascorbic acid in pharmaceuticals and foods by background correction
    Noroozifar, M
    Khorasani-Motlagh, M
    TALANTA, 2003, 61 (02) : 173 - 179
  • [9] Flow injection spectrophotometric determination of L-ascorbic acid in pharmaceutical formulations with on-line solid-phase reactor containing copper (II) phosphate
    Pereira, AV
    Fatibello, O
    ANALYTICA CHIMICA ACTA, 1998, 366 (1-3) : 55 - 62