Novel Flow-through Potentiometric System for Dimethyamine Assessment Using New Ion Exchangers Doped-polymeric Membrane Sensors

被引:2
|
作者
Hassan, Saad S. M. [1 ]
Kamel, Ayman H. [1 ]
Abd El-Naby, Heba [1 ]
机构
[1] Ain Shams Univ, Chem Dept, Fac Sci, Cairo, Egypt
关键词
Potentiometric sensors; Flow injection analysis; determination of dimethylamine; CHROMATOGRAPHY-MASS-SPECTROMETRY; SOLID-PHASE MICROEXTRACTION; PERFORMANCE LIQUID-CHROMATOGRAPHY; ALIPHATIC-AMINES; GAS-CHROMATOGRAPHY; ACCURATE QUANTIFICATION; DIMETHYLAMINE DMA; BIOGENIC-AMINES; WASTE-WATER; TRIMETHYLAMINE;
D O I
10.1002/elan.201800456
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
New simple potentiometric sensing systems are described for the sensitive and selective monitoring of dimethylamine (DMA). These systems are based on using polymeric membranes doped in some ion exchangers such as dimethylamine/phosphomolybdate [(CH3)(2)NH3](2)(2+)[MP](2-) (Sensor I), dimethylamine/tetraphenylborate [(CH3)(2)NH3](+)[TPB](-) (Sensor II) and dimethylamine/phosphotungstate [(CH3)(2)NH3](+)[TP](-) (sensor III). All the sensing systems are incorporated in poly(vinyl chloride) matrix plasticized with o-NPOE. In a Trizma buffer solution of pH 7.1, the sensors exhibit a stable, fast and linear response for 5.0x10(-6)-1.0x10(-2), 2.5x10(-5)-1.0x10(-2), and 5.0x10(-6)-1.0x10(-2) mol L-1 DMA(+) with slopes of 53.2 +/- 0.4, 49.4 +/- 0.6, and 53.8 +/- 0.3 mV decade(-1), and detection limits of 2.0x10(-6) (0.16 mu g mL(-1)), 1.6x10(-5)(1.3 mu g mL(-1)), and 1.4x10(-6) (0.11 mu g mL(-1)) mol L-1 for sensors (I), (II), and (III), respectively. Potentiometric selectivity measurements of these sensors reveal negligible interferences from most common aliphatic and aromatic amines. Satisfactory results are obtained with an average accuracy of 99.5 % and a mean precision of +/- 0.5 %. Validation of the proposed assay methods are examined by measuring the limit of detection, linearity range, accuracy, precision, within-day repeatability, between-days reproducibility and method ruggedness. Good performance characteristics and applicability of these sensors for DMA assessment in different matrices under static and hydrodynamic modes of measurements are demonstrated. The proposed sensors are also prepared in a tubular form and used as DMA detector in a two-channel flow injection setup for continuous monitoring. The frequency rate is 27-53 samples h(-1). The sensors are satisfactory applied for DMA quantification in both biological matrices and environmental samples with recoveries ranging between 95.0 and 104.0 %.
引用
收藏
页码:2635 / 2643
页数:9
相关论文
共 30 条
  • [1] New Potentiometric Sensors for Picrate Determination Using Flow-Through System: Application to Kinetic Assessment of Se(IV)
    Hassan, Saad S. M.
    Badr, Ibrahim H. A.
    Kamel, Ayman H.
    Mohamed, Mona S.
    ELECTROANALYSIS, 2013, 25 (03) : 793 - 801
  • [2] Potentiometric sensing of aqueous phosphate by competition assays using ion-exchanger doped-polymeric membrane electrodes as transducers
    Li, Long
    Shang, Guoliang
    Qin, Wei
    ANALYST, 2016, 141 (15) : 4573 - 4577
  • [3] New Potentiometric Sensors Based on Two Competitive Recognition Sites for Determining Tetracycline Residues Using Flow-Through System
    Moreira, Felismina T. C.
    Kamel, Ayman H.
    Guerreiro, Rafaela L.
    Azevedo, Vera
    Sales, M. Goreti F.
    EUROSENSORS XXIV CONFERENCE, 2010, 5 : 1200 - 1203
  • [4] NEW POLYMERIC MEMBRANE MATERIALS FOR FABRICATING POTENTIOMETRIC ION-SELECTIVE AND BIO-SELECTIVE SENSORS
    MEYERHOFF, ME
    CHA, GS
    MA, SC
    GOLDBERG, HD
    MIDGLEY, AR
    CANTOR, H
    BROWN, RB
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1991, 201 : 167 - PMSE
  • [5] Improving the Biocompatibility of Polymeric Membrane Potentiometric Ion Sensors by Using a Mussel-Inspired Polydopamine Coating
    Jiang, Xiaojing
    Wang, Peng
    Liang, Rongning
    Qin, Wei
    ANALYTICAL CHEMISTRY, 2019, 91 (10) : 6424 - 6429
  • [6] Flow-Through Assay of Quinine Using Solid Contact Potentiometric Sensors Based on Molecularly Imprinted Polymers
    Kamel, Ayman H.
    Sayour, Hossam E. M.
    ELECTROANALYSIS, 2009, 21 (24) : 2701 - 2708
  • [7] FIA potentiometric system based on periodate polymeric membrane sensors for the assessment of ascorbic acid in commercial drinks
    Guerreiro, J. Rafaela L.
    Kamel, Ayman H.
    Sales, M. Goreti F.
    FOOD CHEMISTRY, 2010, 120 (03) : 934 - 939
  • [8] LIQUID-CHROMATOGRAPHIC DETERMINATION OF ACIDS AND ANIONS USING LIQUID MEMBRANE ION-SELECTIVE ELECTRODES IN A POTENTIOMETRIC FLOW-THROUGH DETECTOR
    DEBACKER, BL
    NAGELS, LJ
    ALDERWEIRELDT, FC
    VANBOGAERT, PP
    ANALYTICA CHIMICA ACTA, 1993, 273 (1-2) : 449 - 456
  • [9] POTENTIOMETRIC FLOW-INJECTION DETERMINATION OF BORON BY USING A FLOW-THROUGH TETRAFLUOROBORATE ION-SELECTIVE POLY(VINYL CHLORIDE) MEMBRANE-ELECTRODE
    IMATO, T
    YOSHIZUKA, T
    ISHIBASHI, N
    ANALYTICA CHIMICA ACTA, 1990, 233 (01) : 139 - 141
  • [10] Automatic potentiometric system for quantification of three imidazole derivatives based on new polymeric PVC membrane sensors
    Kamel, Ayman H.
    Argig, Amina A. A.
    IONICS, 2017, 23 (08) : 2201 - 2211