Novel Flow-through Potentiometric System for Dimethyamine Assessment Using New Ion Exchangers Doped-polymeric Membrane Sensors

被引:2
|
作者
Hassan, Saad S. M. [1 ]
Kamel, Ayman H. [1 ]
Abd El-Naby, Heba [1 ]
机构
[1] Ain Shams Univ, Chem Dept, Fac Sci, Cairo, Egypt
关键词
Potentiometric sensors; Flow injection analysis; determination of dimethylamine; CHROMATOGRAPHY-MASS-SPECTROMETRY; SOLID-PHASE MICROEXTRACTION; PERFORMANCE LIQUID-CHROMATOGRAPHY; ALIPHATIC-AMINES; GAS-CHROMATOGRAPHY; ACCURATE QUANTIFICATION; DIMETHYLAMINE DMA; BIOGENIC-AMINES; WASTE-WATER; TRIMETHYLAMINE;
D O I
10.1002/elan.201800456
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
New simple potentiometric sensing systems are described for the sensitive and selective monitoring of dimethylamine (DMA). These systems are based on using polymeric membranes doped in some ion exchangers such as dimethylamine/phosphomolybdate [(CH3)(2)NH3](2)(2+)[MP](2-) (Sensor I), dimethylamine/tetraphenylborate [(CH3)(2)NH3](+)[TPB](-) (Sensor II) and dimethylamine/phosphotungstate [(CH3)(2)NH3](+)[TP](-) (sensor III). All the sensing systems are incorporated in poly(vinyl chloride) matrix plasticized with o-NPOE. In a Trizma buffer solution of pH 7.1, the sensors exhibit a stable, fast and linear response for 5.0x10(-6)-1.0x10(-2), 2.5x10(-5)-1.0x10(-2), and 5.0x10(-6)-1.0x10(-2) mol L-1 DMA(+) with slopes of 53.2 +/- 0.4, 49.4 +/- 0.6, and 53.8 +/- 0.3 mV decade(-1), and detection limits of 2.0x10(-6) (0.16 mu g mL(-1)), 1.6x10(-5)(1.3 mu g mL(-1)), and 1.4x10(-6) (0.11 mu g mL(-1)) mol L-1 for sensors (I), (II), and (III), respectively. Potentiometric selectivity measurements of these sensors reveal negligible interferences from most common aliphatic and aromatic amines. Satisfactory results are obtained with an average accuracy of 99.5 % and a mean precision of +/- 0.5 %. Validation of the proposed assay methods are examined by measuring the limit of detection, linearity range, accuracy, precision, within-day repeatability, between-days reproducibility and method ruggedness. Good performance characteristics and applicability of these sensors for DMA assessment in different matrices under static and hydrodynamic modes of measurements are demonstrated. The proposed sensors are also prepared in a tubular form and used as DMA detector in a two-channel flow injection setup for continuous monitoring. The frequency rate is 27-53 samples h(-1). The sensors are satisfactory applied for DMA quantification in both biological matrices and environmental samples with recoveries ranging between 95.0 and 104.0 %.
引用
收藏
页码:2635 / 2643
页数:9
相关论文
共 30 条
  • [21] Assessment of in vitro percutaneous absorption of glycolic acid through human skin sections using a flow-through diffusion cell system
    Jiang, M
    Qureshi, SA
    JOURNAL OF DERMATOLOGICAL SCIENCE, 1998, 18 (03) : 181 - 188
  • [22] New flow-through analytical system based on ion-selective field effect transistors with optimised calcium selective photocurable membrane for bovine serum analysis
    Abramova, N.
    Bratov, A.
    Ipatov, A.
    Levichev, S.
    Aris, A.
    Rodriguez, E. M.
    TALANTA, 2013, 113 : 31 - 35
  • [23] A NEW CONSTRUCTION OF FLOW-THROUGH SENSORS WITH TUBULAR ION-SELECTIVE CARRIER-PVC MEMBRANES AND SOLID-STATE CEMENT CONTACT
    SCHINDLER, JG
    SCHINDLER, MM
    FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1989, 335 (06): : 553 - 556
  • [24] Rapid identification of biological warfare agents using an instrument employing a light addressable potentiometric sensor and a flow-through immunofiltration-enzyme assay system
    Uithoven, KA
    Schmidt, JC
    Ballman, ME
    BIOSENSORS & BIOELECTRONICS, 2000, 14 (10-11): : 761 - 770
  • [25] Defective cobalt-nitrogen dual-doped carbon materials for enhanced tetracycline hydrochloride degradation in flow-through electro-Fenton-membrane system
    Zhu, Ruiying
    Ma, Hong
    Luo, Xuan
    Zhao, Li
    Pan, Xiaofang
    Yang, Binfei
    Wu, Xiaochun
    Gong, Xiaobo
    PROCESS SAFETY AND ENVIRONMENTAL PROTECTION, 2025, 194 : 941 - 954
  • [26] FLUOROMETRIC-DETERMINATION OF POTASSIUM-ION USING HEXADECYL-ACRIDINE ORANGE IMMOBILIZED ON A POLY(VINYL CHLORIDE) MEMBRANE ATTACHED TO A FLOW-THROUGH CELL
    KAWABATA, Y
    IMASAMA, T
    ISHIBASHI, N
    ANALYTICA CHIMICA ACTA, 1991, 255 (01) : 97 - 101
  • [27] Novel PVC-membrane potentiometric sensors based on a recently synthesized sulfur-containing macrocyclic diamide for Cd2+ ion. Application to flow-injection potentiometry
    Shamsipur, Mojtaba
    Dezaki, Abbas Shirmardi
    Akhond, Morteza
    Sharghi, Hashem
    Paziraee, Zahra
    Alizadeh, Kamal
    JOURNAL OF HAZARDOUS MATERIALS, 2009, 172 (2-3) : 566 - 573
  • [28] Enhanced tetracycline removal using membrane-like air-cathode with high flux and anti-fouling performance in flow-through electro-filtration system
    Song, Xiangru
    Jo, ChungHyok
    Zhou, Minghua
    WATER RESEARCH, 2022, 224
  • [29] The system NaCl-CaCl2-H2O:: Part 3.: Heats of dilution and mixing at 373 to 573 K and 21.5 MPa using a new high-temperature, flow-through calorimeter
    Oakes, CS
    Pitzer, KS
    Sterner, SM
    GEOCHIMICA ET COSMOCHIMICA ACTA, 1998, 62 (07) : 1133 - 1146
  • [30] Novel self-sustained flow-through electrochemical advanced oxidation processes using nano-Fe-0 confined B, N co-doped carbon nanotubes/graphite felt cathode: Higher mineralization efficiency under wider pH
    Su, Pei
    Song, Ge
    Wang, Xuechun
    Zhang, Qizhan
    Fu, Wenyang
    Zhou, Minghua
    SEPARATION AND PURIFICATION TECHNOLOGY, 2023, 318