Indoor air quality in an air-conditioned building in new Delhi and its relationship to ambient air quality

被引:4
|
作者
Prasad, RK
Uma, R
Kansal, A
Gupta, S
Kumar, P
Saksena, S
机构
[1] East West Ctr, Honolulu, HI 96848 USA
[2] AsianPaints, New Delhi, India
[3] Tata Energy Res Inst, New Delhi 110003, India
[4] GGS Indraprastha Univ, New Delhi, India
关键词
indoor air pollution; outdoor air pollution; ventilation; noise; air handling unit;
D O I
10.1159/0000068234
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In an urban city like Delhi, vehicular exhaust is a major source of air pollution in addition to industrial activities emitting uncontrolled air pollutants. This contaminated air is sucked into buildings by air handling units contaminating the indoor air. In addition, indoor air is further contaminated by sources used for cooking, space heating devices, various chemicals and so on. The present paper analyses the indoor and outdoor air quality in a commercial building. The functioning of the air handling unit was also studied in the context of indoor air quality. Pollutants such as asbestos, carbon monoxide, formaldehyde, lead, oxides of nitrogen, ozone, respirable suspended particulates, sulphur dioxide and suspended particulate matter and gases such as oxygen and carbon dioxide were monitored. Copyright (C) 2003 S. Karger AG, Basel.
引用
收藏
页码:334 / 339
页数:6
相关论文
共 50 条
  • [1] Indoor Air Quality Related to Occupancy at an Air-conditioned Public Building
    Ponsoni, Karina
    Goncalves Raddi, Maria Stella
    BRAZILIAN ARCHIVES OF BIOLOGY AND TECHNOLOGY, 2010, 53 (01) : 99 - 103
  • [2] Development and application of an indoor air quality audit to an air-conditioned building in Singapore
    Cheong, KW
    Chong, KY
    BUILDING AND ENVIRONMENT, 2001, 36 (02) : 181 - 188
  • [3] Screening for indoor air quality of air-conditioned off ices
    Wong, L. T.
    Mui, K. W.
    Hui, P. S.
    INDOOR AND BUILT ENVIRONMENT, 2007, 16 (05) : 438 - 443
  • [4] Diagnostics of Unsatisfactory Indoor Air Quality in Air-Conditioned Workplaces
    Mui, K. W.
    Hui, P. S.
    Wong, L. T.
    INDOOR AND BUILT ENVIRONMENT, 2011, 20 (03) : 313 - 320
  • [5] EFFECT OF SPRING GRASS FIRES ON INDOOR AIR QUALITY IN AIR-CONDITIONED OFFICE BUILDING
    Pauraite, J.
    Garbariene, I.
    Minderyte, A.
    Dudoitis, V.
    Mainelis, G.
    Davuliene, L.
    Uoginte, I.
    Plauskaite, K.
    Bycenkiene, S.
    LITHUANIAN JOURNAL OF PHYSICS, 2021, 61 (03): : 191 - 204
  • [6] An epistemic indoor air quality assessment protocol for air-conditioned offices
    Hui, P. S.
    Wong, L. T.
    Mui, K. W.
    INDOOR AND BUILT ENVIRONMENT, 2007, 16 (02) : 139 - 147
  • [7] Adaptive PID Control of Indoor Air Quality for an Air-conditioned Room
    Gu, Xiaosong
    Li, Heng
    Zhao, Litie
    Wang, Hanqing
    INTERNATIONAL CONFERENCE ON INTELLIGENT COMPUTATION TECHNOLOGY AND AUTOMATION, VOL 1, PROCEEDINGS, 2008, : 289 - +
  • [8] Fungi - an indoor air quality assessment parameter for air-conditioned offices
    Mui, K. W.
    Chan, W. Y.
    Wong, L. T.
    Hui, P. S.
    BUILDING SERVICES ENGINEERING RESEARCH & TECHNOLOGY, 2007, 28 (03): : 265 - 274
  • [9] A survey of indoor air quality problems in air-conditioned buildings in India
    Kalaiselvam, S
    Robin, JR
    Jose, S
    Iniyan, S
    Samuel, AA
    INDOOR AIR 2005: PROCEEDINGS OF THE 10TH INTERNATIONAL CONFERENCE ON INDOOR AIR QUALITY AND CLIMATE, VOLS 1-5, 2005, : 893 - 897
  • [10] Development and application of an indoor air quality audit to an air-conditioned tertiary institutional building in the tropics
    Cheong, KWD
    Lau, HYT
    BUILDING AND ENVIRONMENT, 2003, 38 (04) : 605 - 616