Diagnostics of Unsatisfactory Indoor Air Quality in Air-Conditioned Workplaces

被引:5
|
作者
Mui, K. W. [1 ]
Hui, P. S. [1 ]
Wong, L. T. [1 ]
机构
[1] Hong Kong Polytech Univ, Dept Bldg Serv Engn, Kowloon, Hong Kong, Peoples R China
关键词
Screening test; Indoor air quality; IAQ index; Likelihood ratios; Environmental diagnosis; Representative pollutants; EXPRESS ASSESSMENT PROTOCOL; PARTICULATE MATTER; HONG-KONG; OFFICES; POLLUTION; EXPOSURE; HEALTH; FEASIBILITY; POLLUTANTS; BUILDINGS;
D O I
10.1177/1420326X11400880
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This study examines a screening process for environmental diagnosis of indoor air quality (IAQ) problems in air-conditioned office buildings. Diagnosis of IAQ problems in relation to complaints of environmental health effects has not been identified as a precise science and this paper proposes an evaluation tool to address this need. An "IAQ index", the average fractional dose of a set of three representative indoor pollutants, has been developed for this purpose, to be used as a screening parameter for detecting the unsatisfactory factors affecting the IAQ in an air-conditioned office. The wide-ranging set of prescribed IAQ measurements for these investigations can be prohibitive due to complexity, cost and time period taken to obtain results. In this study, a 5-level screening strategy based on the IAQ index to quantify the likelihood of unsatisfactory IAQ in air-conditioned workplaces is being proposed. The proposed assessment tool would be a useful protocol for policymakers and professionals to evaluate the relative environmental performance of office spaces and to investigate any IAQ problem. A proposed set of three measurements are used to inform decision whether to take any further action (more measurements or remedial measures) to allow early diagnosis of IAQ problems in air-conditioned offices to satisfy existing Hong Kong IAQ standards.
引用
收藏
页码:313 / 320
页数:8
相关论文
共 50 条
  • [1] Screening for indoor air quality of air-conditioned off ices
    Wong, L. T.
    Mui, K. W.
    Hui, P. S.
    [J]. INDOOR AND BUILT ENVIRONMENT, 2007, 16 (05) : 438 - 443
  • [2] An epistemic indoor air quality assessment protocol for air-conditioned offices
    Hui, P. S.
    Wong, L. T.
    Mui, K. W.
    [J]. INDOOR AND BUILT ENVIRONMENT, 2007, 16 (02) : 139 - 147
  • [3] A survey of indoor air quality problems in air-conditioned buildings in India
    Kalaiselvam, S
    Robin, JR
    Jose, S
    Iniyan, S
    Samuel, AA
    [J]. INDOOR AIR 2005: PROCEEDINGS OF THE 10TH INTERNATIONAL CONFERENCE ON INDOOR AIR QUALITY AND CLIMATE, VOLS 1-5, 2005, : 893 - 897
  • [4] Adaptive PID Control of Indoor Air Quality for an Air-conditioned Room
    Gu, Xiaosong
    Li, Heng
    Zhao, Litie
    Wang, Hanqing
    [J]. INTERNATIONAL CONFERENCE ON INTELLIGENT COMPUTATION TECHNOLOGY AND AUTOMATION, VOL 1, PROCEEDINGS, 2008, : 289 - +
  • [5] Fungi - an indoor air quality assessment parameter for air-conditioned offices
    Mui, K. W.
    Chan, W. Y.
    Wong, L. T.
    Hui, P. S.
    [J]. BUILDING SERVICES ENGINEERING RESEARCH & TECHNOLOGY, 2007, 28 (03): : 265 - 274
  • [6] Indoor Air Quality Related to Occupancy at an Air-conditioned Public Building
    Ponsoni, Karina
    Goncalves Raddi, Maria Stella
    [J]. BRAZILIAN ARCHIVES OF BIOLOGY AND TECHNOLOGY, 2010, 53 (01) : 99 - 103
  • [7] Development and application of an indoor air quality audit to an air-conditioned building in Singapore
    Cheong, KW
    Chong, KY
    [J]. BUILDING AND ENVIRONMENT, 2001, 36 (02) : 181 - 188
  • [8] Indoor air quality and energy performance of air-conditioned office buildings in Singapore
    Sekhar, SC
    Tham, KW
    Cheong, KW
    [J]. INDOOR AIR, 2003, 13 (04) : 315 - 331
  • [9] Evaluation on screening strategies for indoor air quality assessments in air-conditioned offices
    Wong, L. T.
    Mui, K. W.
    Hui, P. S.
    [J]. BUILDING SERVICES ENGINEERING RESEARCH & TECHNOLOGY, 2009, 30 (03): : 203 - 212
  • [10] An energy impact assessment of indoor air quality acceptance for air-conditioned offices
    Wong, L. T.
    Mui, K. W.
    Shi, K. L.
    Hui, P. S.
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2008, 49 (10) : 2815 - 2819