A survey of indoor air quality problems in air-conditioned buildings in India

被引:0
|
作者
Kalaiselvam, S [1 ]
Robin, JR [1 ]
Jose, S [1 ]
Iniyan, S [1 ]
Samuel, AA [1 ]
机构
[1] Anna Univ, Dept Mech Engn, Madras 600025, Tamil Nadu, India
关键词
indoor air quality; comfort;
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The indoor environment is intuitively considered a refuge, a safe place not only from inclement weather and temperature extremes but also from outdoor air pollutants. Over the years, buildings have been made more airtight to conserve energy The scientific evidence has indicated that the air within homes and other buildings can be more severely polluted than the outdoor air in even the largest and most industrialized cities. Other research indicates that people spend approximately 90 percent of their time indoors. Thus, for many people, the risks to health may be greater due to exposure to air pollution indoors than outdoors. Maintaining a healthy and comfortable indoor environment in any building requires integrating many components of a complex system. A survey was conducted to study the air quality related factors and their influence in various types of offices. The parameters such as CO2 content, air velocity, dust, odour and humidity were analyzed. This survey will helpful in detecting the presence or absence of health problems. It is noticed that among various building analyzed Restaurants, software companies and computer centres are found to be poorly ventilated. Odour seems to be a problem in majority of the buildings.
引用
收藏
页码:893 / 897
页数:5
相关论文
共 50 条
  • [1] Indoor air quality and energy performance of air-conditioned office buildings in Singapore
    Sekhar, SC
    Tham, KW
    Cheong, KW
    [J]. INDOOR AIR, 2003, 13 (04) : 315 - 331
  • [2] Indoor air quality and ventilation measurements in nine air-conditioned buildings in Singapore
    Sekhar, SC
    Tham, KW
    Cheong, D
    [J]. PROCEEDINGS OF THE 4TH INTERNATIONAL CONFERENCE ON INDOOR AIR QUALITY, VENTILATION AND ENERGY CONSERVATION IN BUILDINGS, VOLS I-III, 2001, : 715 - 722
  • [3] INDOOR/OUTDOOR AIR POLLUTANT RELATIONSHIPS FOR AIR-CONDITIONED BUILDINGS
    YOCUM, JE
    COTE, WA
    [J]. ASHRAE JOURNAL, 1971, 13 (01): : 54 - &
  • [4] Diagnostics of Unsatisfactory Indoor Air Quality in Air-Conditioned Workplaces
    Mui, K. W.
    Hui, P. S.
    Wong, L. T.
    [J]. INDOOR AND BUILT ENVIRONMENT, 2011, 20 (03) : 313 - 320
  • [5] Screening for indoor air quality of air-conditioned off ices
    Wong, L. T.
    Mui, K. W.
    Hui, P. S.
    [J]. INDOOR AND BUILT ENVIRONMENT, 2007, 16 (05) : 438 - 443
  • [6] Comparative study of the indoor air quality of naturally ventilated and air-conditioned bedrooms of residential buildings in Singapore
    Wong, NH
    Huang, B
    [J]. BUILDING AND ENVIRONMENT, 2004, 39 (09) : 1115 - 1123
  • [7] Effects of Partition on Thermal Comfort, Indoor Air Quality, Energy Consumption, and Perception in Air-Conditioned Buildings
    Aryal, Pradip
    Leephakpreeda, Thananchai
    [J]. JOURNAL OF SOLAR ENERGY ENGINEERING-TRANSACTIONS OF THE ASME, 2016, 138 (05):
  • [8] An epistemic indoor air quality assessment protocol for air-conditioned offices
    Hui, P. S.
    Wong, L. T.
    Mui, K. W.
    [J]. INDOOR AND BUILT ENVIRONMENT, 2007, 16 (02) : 139 - 147
  • [9] Fungi - an indoor air quality assessment parameter for air-conditioned offices
    Mui, K. W.
    Chan, W. Y.
    Wong, L. T.
    Hui, P. S.
    [J]. BUILDING SERVICES ENGINEERING RESEARCH & TECHNOLOGY, 2007, 28 (03): : 265 - 274
  • [10] Adaptive PID Control of Indoor Air Quality for an Air-conditioned Room
    Gu, Xiaosong
    Li, Heng
    Zhao, Litie
    Wang, Hanqing
    [J]. INTERNATIONAL CONFERENCE ON INTELLIGENT COMPUTATION TECHNOLOGY AND AUTOMATION, VOL 1, PROCEEDINGS, 2008, : 289 - +