Comparative study of the indoor air quality of naturally ventilated and air-conditioned bedrooms of residential buildings in Singapore

被引:99
|
作者
Wong, NH [1 ]
Huang, B [1 ]
机构
[1] Natl Univ Singapore, Sch Design & Environm, Dept Bldg, Singapore 117566, Singapore
关键词
indoor air quality; thermal comfort; natural ventilation;
D O I
10.1016/j.buildenv.2004.01.024
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
indoor air quality (IAQ) measurements were carried out in 3 residential dwellings in Singapore to find out the indoor air quality (IAQ) of the bedrooms. It was found that when the subjects utilized air-conditioners while sleeping, there was a considerable build-up of carbon dioxide (CO2) ( > 1000 ppm) for all types of air-conditioners. These CO2 levels were substantial higher as compared to naturally ventilated bedrooms. A survey was also conducted to investigate whether occupants exhibited sick building syndrome (SBS) symptoms while sleeping in air-conditioned (AC) as well as naturally ventilated (NV) bedrooms. A comparison showed that almost all occupants who used air-conditioners while sleeping exhibited one or more SBS symptoms and these occupants usually displayed more SBS symptoms after using air-conditioning than when they utilized natural ventilation. The survey also revealed that the frequency and duration of usage of air conditioning has important impact on the exhibition of the SBS symptoms. (C) 2004 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1115 / 1123
页数:9
相关论文
共 50 条
  • [1] Indoor air quality and energy performance of air-conditioned office buildings in Singapore
    Sekhar, SC
    Tham, KW
    Cheong, KW
    [J]. INDOOR AIR, 2003, 13 (04) : 315 - 331
  • [2] Indoor air quality and ventilation measurements in nine air-conditioned buildings in Singapore
    Sekhar, SC
    Tham, KW
    Cheong, D
    [J]. PROCEEDINGS OF THE 4TH INTERNATIONAL CONFERENCE ON INDOOR AIR QUALITY, VENTILATION AND ENERGY CONSERVATION IN BUILDINGS, VOLS I-III, 2001, : 715 - 722
  • [3] Comparison of Indoor Air Quality for Air-Conditioned and Naturally Ventilated Office Spaces in Urban Area
    Jain, Supreme
    Garg, Divyam
    Goel, Anubha
    [J]. INDOOR ENVIRONMENTAL QUALITY, ACIEQ, 2020, 60 : 1 - 8
  • [4] Measurement and evaluation of indoor air quality in naturally ventilated residential buildings
    Yin, Haiguo
    Liu, Chunxue
    Zhang, Leiming
    Li, Angui
    Ma, Zhenjun
    [J]. INDOOR AND BUILT ENVIRONMENT, 2019, 28 (10) : 1307 - 1323
  • [5] Feasibility study of an indoor air quality measurement protocol on 12 parameters in mechanically ventilated and air-conditioned buildings
    Chao, CY
    Chan, GY
    Ho, L
    [J]. INDOOR AND BUILT ENVIRONMENT, 2001, 10 (01) : 3 - 19
  • [6] THERMAL COMFORT IN THE HUMID TROPICS - FIELD EXPERIMENTS IN AIR-CONDITIONED AND NATURALLY VENTILATED BUILDINGS IN SINGAPORE
    DEDEAR, RJ
    LEOW, KG
    FOO, SC
    [J]. INTERNATIONAL JOURNAL OF BIOMETEOROLOGY, 1991, 34 (04) : 259 - 265
  • [7] A survey of indoor air quality problems in air-conditioned buildings in India
    Kalaiselvam, S
    Robin, JR
    Jose, S
    Iniyan, S
    Samuel, AA
    [J]. INDOOR AIR 2005: PROCEEDINGS OF THE 10TH INTERNATIONAL CONFERENCE ON INDOOR AIR QUALITY AND CLIMATE, VOLS 1-5, 2005, : 893 - 897
  • [8] Development and analysis of a metamodel to represent the thermal behavior of naturally ventilated and artificially air-conditioned residential buildings
    Melo, A. P.
    Fossati, M.
    Versage, R. S.
    Sorgato, M. J.
    Scalco, V. A.
    Lamberts, R.
    [J]. ENERGY AND BUILDINGS, 2016, 112 : 209 - 221
  • [9] Development and application of an indoor air quality audit to an air-conditioned building in Singapore
    Cheong, KW
    Chong, KY
    [J]. BUILDING AND ENVIRONMENT, 2001, 36 (02) : 181 - 188
  • [10] AIRBORNE MICROBIAL CONTAMINANTS IN INDOOR ENVIRONMENTS - NATURALLY VENTILATED AND AIR-CONDITIONED HOMES
    KODAMA, AM