Comparison of Indoor Air Quality for Air-Conditioned and Naturally Ventilated Office Spaces in Urban Area

被引:10
|
作者
Jain, Supreme [1 ]
Garg, Divyam [1 ]
Goel, Anubha [1 ,2 ]
机构
[1] Indian Inst Technol, Dept Civil Engn, Kanpur, Uttar Pradesh, India
[2] Indian Inst Technol, Ctr Environm Sci & Engn, Kanpur, Uttar Pradesh, India
来源
关键词
IAQ; Office microenvironment; Particles; Ventilation; Activity level; PARTICULATE MATTER; EXPOSURE; PARTICLES; CHILDREN; COARSE; PM;
D O I
10.1007/978-981-15-1334-3_1
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Indoor air quality (IAQ) is affected by indoor pollution sources that release gases or particles into the air and depending on ventilation conditions, outdoor ambient air quality can also be contributing factor. Inadequate ventilation by limiting inflow-outflow of pollutants, proximity to field or busy road can increase indoor pollutant levels. For this study, two offices, one with natural ventilation and other with central AC system, within residential campus of IIT Kanpur were selected. Air quality in offices with varying ventilation conditions was monitored simultaneously indoor and outdoor. The aim was to compare the data for the two locations and elicit influence of ventilation conditions on indoor pollutant levels. Size segregated mass concentration of ambient aerosols and particle number concentration (PNC) were determined for indoor using cascade impactor, MOUDI and OPC, respectively. Outdoor coarse particle concentration (PM10) was determined using HVS sampler. The PM concentration was found to be highest in naturally ventilated office. As per the recently released ISHRAE standards for indoor environment (ISHRAE Standard-10001:2016), minimum acceptable limits for Class C are PM10 < 100 mu g/m(3) and PM2.5 < 25 mu g/m(3). Levels of particles recorded in these office spaces were 4-6 times higher than ISHRAE acceptable limits for PM2.5 and PM10, respectively. Particle number concentration (PNC) was also higher in naturally ventilated office space as concentration was more than 400,000 particles/cm(3) (<1 mu m) as compared to airconditioned office space (160,000 particles/cm(3)). The I/O ratio for PM10 was found to be 0.64 and 2.93 for Office 1 and Office 2, respectively.
引用
收藏
页码:1 / 8
页数:8
相关论文
共 50 条
  • [1] Comparative study of the indoor air quality of naturally ventilated and air-conditioned bedrooms of residential buildings in Singapore
    Wong, NH
    Huang, B
    BUILDING AND ENVIRONMENT, 2004, 39 (09) : 1115 - 1123
  • [2] A Thermal Comfort Levels Investigation of a Naturally Ventilated and Air-Conditioned Office
    Daghigh, R.
    Adam, N. M.
    Sopian, K.
    Zaharim, A.
    Sahari, B. B.
    SMO 08: PROCEEDINGS OF THE 8TH WSEAS INTERNATIONAL CONFERENCE ON SIMULATION, MODELLING AND OPTIMIZATION, 2008, : 189 - +
  • [3] Indoor air quality and energy performance of air-conditioned office buildings in Singapore
    Sekhar, SC
    Tham, KW
    Cheong, KW
    INDOOR AIR, 2003, 13 (04) : 315 - 331
  • [4] AIRBORNE MICROBIAL CONTAMINANTS IN INDOOR ENVIRONMENTS - NATURALLY VENTILATED AND AIR-CONDITIONED HOMES
    KODAMA, AM
    MCGEE, RI
    ARCHIVES OF ENVIRONMENTAL HEALTH, 1986, 41 (05): : 306 - 311
  • [5] Cross-city comparison of indoor air temperatures in air-conditioned spaces
    Kim, H.
    Chun, C.
    Kwok, A.
    Ota, A.
    Tamura, A.
    INDOOR AIR, 2011, 21 (04) : 311 - 318
  • [6] EFFECT OF SPRING GRASS FIRES ON INDOOR AIR QUALITY IN AIR-CONDITIONED OFFICE BUILDING
    Pauraite, J.
    Garbariene, I.
    Minderyte, A.
    Dudoitis, V.
    Mainelis, G.
    Davuliene, L.
    Uoginte, I.
    Plauskaite, K.
    Bycenkiene, S.
    LITHUANIAN JOURNAL OF PHYSICS, 2021, 61 (03): : 191 - 204
  • [7] Comparison of numerical simulation and experimental study on indoor air quality of air-conditioned office building in desert climate
    Wahhad, A. M.
    Adam, N. M.
    Sapuan, S. M.
    INTERNATIONAL JOURNAL OF AUTOMOTIVE AND MECHANICAL ENGINEERING, 2015, 12 : 3109 - 3124
  • [8] METHODS OF IMPROVING AIR QUALITY IN AIR-CONDITIONED SPACES
    SWANTON, JR
    ASHRAE JOURNAL-AMERICAN SOCIETY OF HEATING REFRIGERATING AND AIR-CONDITIONING ENGINEERS, 1973, 15 (06): : 29 - 36
  • [9] FIELD STUDY OF AIR QUALITY IN AIR-CONDITIONED SPACES
    SWANTON, JR
    ASHRAE JOURNAL, 1971, 13 (01): : 55 - &
  • [10] Screening for indoor air quality of air-conditioned off ices
    Wong, L. T.
    Mui, K. W.
    Hui, P. S.
    INDOOR AND BUILT ENVIRONMENT, 2007, 16 (05) : 438 - 443