Comparison of Indoor Air Quality for Air-Conditioned and Naturally Ventilated Office Spaces in Urban Area

被引:10
|
作者
Jain, Supreme [1 ]
Garg, Divyam [1 ]
Goel, Anubha [1 ,2 ]
机构
[1] Indian Inst Technol, Dept Civil Engn, Kanpur, Uttar Pradesh, India
[2] Indian Inst Technol, Ctr Environm Sci & Engn, Kanpur, Uttar Pradesh, India
来源
关键词
IAQ; Office microenvironment; Particles; Ventilation; Activity level; PARTICULATE MATTER; EXPOSURE; PARTICLES; CHILDREN; COARSE; PM;
D O I
10.1007/978-981-15-1334-3_1
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Indoor air quality (IAQ) is affected by indoor pollution sources that release gases or particles into the air and depending on ventilation conditions, outdoor ambient air quality can also be contributing factor. Inadequate ventilation by limiting inflow-outflow of pollutants, proximity to field or busy road can increase indoor pollutant levels. For this study, two offices, one with natural ventilation and other with central AC system, within residential campus of IIT Kanpur were selected. Air quality in offices with varying ventilation conditions was monitored simultaneously indoor and outdoor. The aim was to compare the data for the two locations and elicit influence of ventilation conditions on indoor pollutant levels. Size segregated mass concentration of ambient aerosols and particle number concentration (PNC) were determined for indoor using cascade impactor, MOUDI and OPC, respectively. Outdoor coarse particle concentration (PM10) was determined using HVS sampler. The PM concentration was found to be highest in naturally ventilated office. As per the recently released ISHRAE standards for indoor environment (ISHRAE Standard-10001:2016), minimum acceptable limits for Class C are PM10 < 100 mu g/m(3) and PM2.5 < 25 mu g/m(3). Levels of particles recorded in these office spaces were 4-6 times higher than ISHRAE acceptable limits for PM2.5 and PM10, respectively. Particle number concentration (PNC) was also higher in naturally ventilated office space as concentration was more than 400,000 particles/cm(3) (<1 mu m) as compared to airconditioned office space (160,000 particles/cm(3)). The I/O ratio for PM10 was found to be 0.64 and 2.93 for Office 1 and Office 2, respectively.
引用
收藏
页码:1 / 8
页数:8
相关论文
共 50 条
  • [31] An energy impact assessment of indoor air quality acceptance for air-conditioned offices
    Wong, L. T.
    Mui, K. W.
    Shi, K. L.
    Hui, P. S.
    ENERGY CONVERSION AND MANAGEMENT, 2008, 49 (10) : 2815 - 2819
  • [32] Indoor air quality and ventilation measurements in nine air-conditioned buildings in Singapore
    Sekhar, SC
    Tham, KW
    Cheong, D
    PROCEEDINGS OF THE 4TH INTERNATIONAL CONFERENCE ON INDOOR AIR QUALITY, VENTILATION AND ENERGY CONSERVATION IN BUILDINGS, VOLS I-III, 2001, : 715 - 722
  • [33] Field study on thermal comfort in naturally ventilated and air-conditioned university classrooms
    Fabozzi, Michael
    Dama, Alessandro
    INDOOR AND BUILT ENVIRONMENT, 2020, 29 (06) : 851 - 859
  • [34] Indoor air quality in an air-conditioned building in new Delhi and its relationship to ambient air quality
    Prasad, RK
    Uma, R
    Kansal, A
    Gupta, S
    Kumar, P
    Saksena, S
    INDOOR AND BUILT ENVIRONMENT, 2002, 11 (06) : 334 - 339
  • [35] Indoor Air Quality in Naturally Ventilated Italian Classrooms
    Fuoco, Fernanda Carmen
    Stabile, Luca
    Buonanno, Giorgio
    Trassiera, Concepcion Vargas
    Massimo, Angelamaria
    Russi, Aldo
    Mazaheri, Mandana
    Morawska, Lidia
    Andrade, Alexandro
    ATMOSPHERE, 2015, 6 (11) : 1652 - 1675
  • [36] Indoor air quality in naturally ventilated dwellings in Spain
    Garcia-Ortega, Sonia
    Linares-Alemparte, Pilar
    INFORMES DE LA CONSTRUCCION, 2023, 75 (572)
  • [37] Indoor air quality and energy performance of air-conditioned office buildings in Singapore (vol 13, pg 315, 2003)
    Sekhar, SC
    Tham, KW
    Cheong, KW
    INDOOR AIR, 2004, 14 (02) : 144 - 144
  • [38] The impact of building operations on urban heat/cool islands under urban densification: A comparison between naturally-ventilated and air-conditioned buildings
    Duan, Shuangping
    Luo, Zhiwen
    Yang, Xinyan
    Li, Yuguo
    APPLIED ENERGY, 2019, 235 : 129 - 138
  • [39] Indoor Environmental Quality Benchmarks for Air-conditioned Offices in the Subtropics
    Mui, K. W.
    Wong, L. T.
    Hui, P. S.
    INDOOR AND BUILT ENVIRONMENT, 2009, 18 (02) : 123 - 129
  • [40] Indoor air pollution in Air-Conditioned bus and non-Air-Conditioned bus
    Husna, I. E.
    Unzilatirrizqi, Y. E. R. D.
    Sarifuddin
    Wijinurhayati, A. A.
    2ND INTERNATIONAL CONFERENCE ON ENVIRONMENT, SUSTAINABILITY ISSUES, AND COMMUNITY DEVELOPMENT, 2021, 623